ECB violations
150-154 Lefferts Avenue, Brooklyn • Block 01328 • Lot 0016
45 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 26, 2026 | 39193989H | ACTIVE | CLASS - 2 | 1) IN-CAR PHONE COMMUNICATION INOPERATIVE. 2) CLEANING OF ELEVATOR PIT. 3) ADJUST CAR FLOOR TO LANDING SILL ON ALL DE... | $625 | $625 | Sep 2, 2026 |
| Jun 25, 2026 | 39555866N | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1 MISSING PROJECT INFORMATION PANEL CONTRARY TO BC 3... | $1,250 | $1,250 | Sep 2, 2026 |
| Jun 25, 2026 | 39555865L | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE AT EXPO# 1 ON EXISTING 6 STORY MULTIPLE DWELLING OCCUPIED BUIL... | $1,250 | $1,250 | Sep 2, 2026 |
| Apr 20, 2026 | 39553217Y | ACTIVE | CLASS - 2 | AT HE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF T... | $1,280 | $1,280 | Jun 24, 2026 |
| Mar 16, 2026 | 39551802X | ACTIVE | CLASS - 2 | AT HE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF T... | $1,250 | $1,250 | Jan 4, 2027 |
| Mar 16, 2026 | 39551803H | ACTIVE | CLASS - 2 | AT HE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 WITH MISSING BOLT... | $2,400 | $2,400 | Jan 4, 2027 |
| Oct 16, 2025 | 39546041Y | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION, A SIDEWALK SHED WAS OBSERVED TO BE INSTALLED AT THE PREMISES. UPON REVIEWING DEPARTMENT RE... | $1,250 | $1,250 | Jul 23, 2026 |
| Aug 28, 2025 | 39158631J | RESOLVE | CLASS - 1 | ONLY ELEVATOR IN A MULTIPLE DWELLING OUT OF SERVICE. THIS CONDITION AFFECTS NUMEROUS TENANTS, INCLUDING THOSE WITH SP... | $1,250 | $1,250 | Nov 12, 2025 |
| Jul 30, 2025 | 39155400Z | RESOLVE | CLASS - 1 | RESTORE SERVICE TO DEVICE. DEVICE FAILED REINSPECTION. MAKE ALL NECESSARY REPAIRS AND CONTACT THIS DEPARTMENT IN ORDE... | $1,250 | $1,250 | Oct 8, 2025 |
| Jul 21, 2025 | 39154269H | RESOLVE | CLASS - 1 | : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A PREVIOUSLY ISSUED CEASE USE ORDER REMAINS IN EFFECT. UPON ... | $3,125 | $3,125 | Oct 1, 2025 |
| Apr 29, 2025 | 39146469M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A PREVIOUSLY ISSUED CEASE USE ORDER REMAINS IN EFFECT. UPON IN... | $6,250 | $6,250 | Jul 9, 2025 |
| Apr 9, 2025 | 39144390K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A PREVIOUSLY ISSUED CEASE USE ORDER REMAINS IN EFFECT. UPON IN... | $1,250 | $1,250 | Jun 18, 2025 |
| Mar 18, 2025 | 39141976Y | RESOLVE | CLASS - 1 | CEASE USE ITEMS: NO RECORD OF CATEGORY 5 TEST BEING PERFORMED AND ACCEPTED BY THIS DEPARTMENT. REMEDY: FILE AND PERFO... | $1,250 | $1,250 | May 28, 2025 |
| Nov 14, 2024 | 39130219N | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $3,125 | $3,125 | Jan 22, 2025 |
| May 20, 2024 | 39114843R | ACTIVE | CLASS - 2 | ATOI OBSERVED SIDAWALK SHED BUILT ON EXP 1 OF THE 6 STORY BUILDING. AS PER DOB FILE NO PERMIT WAS ISSUED, OBTAIN A PE... | $3,125 | $3,125 | Jun 5, 2025 |
| Jan 12, 2024 | 39524772K | ACTIVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 EXTENDED APPROXI... | $2,500 | $2,500 | Apr 17, 2024 |
| Jan 12, 2024 | 39524814J | ACTIVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 UPON REVIEW OF T... | $1,250 | $1,250 | Apr 17, 2024 |
| Nov 29, 2023 | 39100316H | RESOLVE | CLASS - 1 | CLASS 1 ITEM: NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 ... | $3,125 | $3,125 | Jun 23, 2025 |
| Oct 31, 2023 | 39098341J | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED FACADE AT EXP#1 2 AND 4 IN STATE OF DISREPAIR. AT EXP#1 AND 2 FACADE HAVE CRACKS. EXP#... | $2,500 | $1,969 | Jan 10, 2024 |
| Jun 16, 2023 | 39088672P | ACTIVE | CLASS - 1 | CLASS 1::: FILE AND OBTAIN PERMIT TO INSTALL DLM ON THIS DEVICE. THIS IS A SAFETY SYSTEM REQUIRED TO BE ON ALL ELEVAT... | $1,250 | $0 | Aug 23, 2023 |
| Dec 28, 2022 | 39076447K | RESOLVE | CLASS - 2 | SMOKE ALARM DEFECTIVE ON FEDERAL OIL FIRED BOILER. CORRECT VIOLATING CONDITION & SUBMIT A CERTIFICATE OF CORRECTION. | $0 | $0 | Mar 8, 2023 |
| Mar 2, 2022 | 39057270K | ACTIVE | CLASS - 1 | AT EXP.#2 AND 4 FIRE ESCAPE LADDER LANDING AREA EXCESSIVE DEBRIS AND HOUSEHOLD ITEMS. CLEAR EXIT PASSAGEWAY TO STREET... | $6,250 | $0 | Jul 6, 2022 |
| Nov 1, 2021 | 37021926R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39018124K ISSUED2/24/20 &TO FILE C/C PURSUANT TO28-201... | $1,250 | $0 | Mar 23, 2022 |
| Jun 11, 2021 | 39042724Y | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $3,125 | -$3,125 | Nov 3, 2021 |
| Mar 11, 2021 | 39037525P | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $3,125 | -$3,125 | Aug 4, 2021 |
| Sep 28, 2020 | 37020173R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#38270359N ISSUED ON 6/25/2019,AND TO FILE ... | $3,125 | $0 | Feb 17, 2021 |
| Feb 24, 2020 | 39018124K | ACTIVE | CLASS - 2 | SOOT AROUND BOILER,MISSING GUARD ON SUPPLY PUMP,SEAL BASE OF CHIMNEY | $625 | $0 | Jul 1, 2020 |
| Oct 28, 2019 | 39011859J | ACTIVE | CLASS - 2 | THERE IS STORAGE AT THE OIL TANK-THERE IS STORAGE AT THE GAS METERS; CORRECT VIOLATIONS AND SUBMIT THE CERTIFICATE OF... | $3,125 | $0 | Oct 2, 2020 |
| Jun 25, 2019 | 38270359N | RESOLVE | CLASS - 2 | 02X10,14I09. 02X10-REPAIR PHONE; 14I09-REPLACE CAR MIRROR | $625 | $0 | Oct 21, 2019 |
| Apr 30, 2019 | 38269626K | RESOLVE | CLASS - 2 | 02X10,71M07,60Q07,60M07,40I10,39M07,41M07,100I10. 02X10-REPAIR PHONE,71M07-PROVIDE PIT LIGHT SWITCH; 50Q07-PROVIDE MO... | $0 | $0 | Aug 12, 2019 |
| Jan 2, 2019 | 39001048R | ACTIVE | CLASS - 2 | GAS PIOLIT REGULATOR IS MISSING VENT LIMITER-REAR FLAME SIGHT GLASS IS MISSING-OIL PUMP BELT GUARD IS MISSING-BURNER ... | $625 | $0 | Jun 3, 2019 |
| May 3, 2016 | 38242202R | RESOLVE | CLASS - 1 | 05E02,05M07,08V01,56Y10,56B07,60B07,60X10,40R07,67X10,68BB07,56L10, 61L10,07X10. 56B-ADD OIL IN MACHINE; 60B-PROVIDE ... | $2,500 | -$2,500 | Jun 20, 2016 |
| Mar 29, 2016 | 38241790H | RESOLVE | CLASS - 1 | 05M07;20B11;29*E10;35Q13;38R10;42R10;44H10;59O02;67X10;68B07;70O02. 05-M-07 PROVIDE A DOOR ZONE RESTRICTION DEVICE. 2... | $10,000 | $0 | May 16, 2016 |
| Oct 27, 2015 | 38239073M | RESOLVE | CLASS - 1 | *77M07,*52B14,*72M07,*67M07; 14M07,03I10,42G11,61G11,43X10,42M07,69B1145U05,60X10,44H08,05M07,16T07,10J01,10M07,100M0... | $1,000 | $0 | Apr 27, 2016 |
| Nov 5, 2014 | 38233530L | RESOLVE | CLASS - 2 | 67M07,14C10,15M07,32H10,39O03,40M07,16M07,100M07. 67M-PROVIDE PHONE SYSTEM IN THE CAR; 39Q,16M-INSTALL GUARD ON DOOR ... | $2,500 | $0 | Dec 22, 2014 |
| Nov 9, 2013 | 35029198L | ACTIVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED: ATP 4F APT 4F ERECTED FULL HEIGHT PARTITION (6 INCHES BELOW CEILING) REMEDY: IMMEDIATE... | $4,000 | $0 | Dec 30, 2013 |
| Sep 23, 2013 | 38228304R | RESOLVE | CLASS - 2 | 41I10,10B07,42N08,20I11,56Y10,29Q03,56Y13,40T07,56Y02,40O02,99U05,15M07,40M07,46M07,40I10,68B07,60L10,61M07,61I10,67M... | $2,500 | $0 | Nov 18, 2013 |
| Oct 19, 2012 | 38223353K | RESOLVE | CLASS - 2 | 70O02,32H10,77B11,61I10,61D06,44H08,56Y02,56Y13,41I11,41T07,41W07,39O02,29Q07.77B11-REPLACE TOEGUARD TO 21'AS PER APP... | $2,500 | $0 | Dec 3, 2012 |
| Apr 23, 2012 | 32071941Z | ACTIVE | CLASS - 2 | B254,15,32A,34A,50A,B,C,D,E. 50A- MISSING PULLY GUARD @ TRANSFER PUMP,50B- IMPROPER SEAL @ BOILER CHAMBER DOOR, 50C- ... | $2,500 | $0 | Jun 11, 2012 |
| Jul 20, 2009 | 38203580M | RESOLVE | CLASS - 3 | 58F10.41I11.56Y13.70O2.40O2.58 REPAIR WORM AND GEAR 41 REPLACE DOOR TO MACHINE RM 56 SEAL OIL LEAK 32 ADJUST CAR GUID... | $200 | $0 | Sep 14, 2009 |
| Mar 27, 2006 | 34511911R | ACTIVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS: FROM; ORDINARY AND ACCESSORY USE IN CELLAR. TO: OR... | $800 | $0 | Jan 29, 2007 |
| Mar 27, 2006 | 34511912Z | ACTIVE | Hazardous | WORK W/O A PERMIT. WORK NOTED:CREATED TWO BEDROOMS IN CELLAR W/O WINDOWS, SPACE FOR KITCHEN WITH GAS STOVE, BATHROOM ... | $800 | $0 | Jan 29, 2007 |
| May 13, 2004 | 38147230Z | RESOLVE | Non-Hazardous | 08V01,15I11,03M07,71M07,10H11,66O02,38O02,28B10,28Q03,05M07,20Q03,16M07,21Q07,34R10,59I10,39I10,39Z10,16R09. CAPACITY... | $2,500 | $0 | Jul 25, 2011 |
| Jul 7, 1994 | 38044634N | RESOLVE | Non-Hazardous | 17L,37G,46K,53X,55X,57O,73O,74AM,74BM,74CM,75M,(74A) TOE GUARD (74B)CAPACITY PLATE (74C) NYC DESIGNATED ELEVATOR NO (... | $1,000 | $0 | Nov 14, 1994 |
| Jun 1, 1993 | 38033113Y | RESOLVE | Non-Hazardous | 14L, 17I, 73O. | $1,000 | $0 | Nov 15, 1993 |