| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 12, 2022 | 39500499M | RESOLVE | CLASS - 2 | OBSERVED PLASTIC JERSEY BARRIERS ON ROADWAY AT EXP#1 NOT AS PER MANUFACTURE SPECIFICATIONS, OBSERVED BARRIERS NOT LOC... | $0 | $0 | Aug 17, 2022 |
| Feb 24, 2022 | 35647568H | RESOLVE | CLASS - 1 | BC3301.1.2 FAILURE TO PROVIDE FIREGUARD FOR TORCH OPS AS NOTED:ATOI@ACTIVE CONST SITE,OBSERVED HOTWORK/WELDING BEING ... | $2,500 | $0 | Nov 21, 2022 |
| Feb 24, 2022 | 35647569J | RESOLVE | CLASS - 1 | BC2104.6 FAILURE TO PROVIDE MASONRY CMU WALL CONST BRACING ACCORDANCE W/TMS602/ACI530.1/ASCE6SEC3.3E.AS NOTED:ATOI@AC... | $2,500 | $0 | Nov 21, 2022 |
| Feb 24, 2022 | 35647570R | RESOLVE | CLASS - 1 | BC3301.7 FAILURE TO PROVIDE APPROVED DESIGN DETAILS AS NOTED:ATOI@ACTIVE CONST SITE,OBSERVED WORKER ON TOP OF UNBRACE... | $625 | $0 | Jul 13, 2022 |
| Feb 24, 2022 | 35647566Y | RESOLVE | CLASS - 2 | AC28-105.12 CONDITION OF NB PERMIT AS NOTED:ATOI@ACTIVE CONST SITE,OBSERVED ON BISSYSTEM NBPERMIT321592139-01-NB W/'L... | $0 | $0 | Jul 13, 2022 |
| Feb 24, 2022 | 35647567X | RESOLVE | CLASS - 2 | 28-407.1 FAILURE TO PROVIDE NYS LIC-WELDER AS NOTED:ATOI@ACTIVE CONST SITE,OBSERVED WORKER ON LADDER WELDING STEEL.UP... | $625 | $0 | Jul 13, 2022 |
| Mar 22, 2016 | 35183580H | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION. NO HAND RAILS. NOTE: AT THE TIME O... | $1,000 | $0 | May 10, 2016 |
| Mar 22, 2016 | 35183581J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION. NOTE: AT THE TIME OF MY INSPECTION OF... | $2,400 | $0 | May 10, 2016 |
| Mar 22, 2016 | 35183579K | RESOLVE | CLASS - 1 | PARTIAL STOP WORK ORDER. FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTYAFFECTED BY CONSTRUCTION OPERATION. NOTE: AT TH... | $2,400 | $0 | May 10, 2016 |
| Mar 22, 2016 | 35183582L | RESOLVE | CLASS - 1 | SEC. 48 FAILURE TO ADEQUATE SUPERVIDE WORK AT A CONSTRUCTION SITE,SO AS TO MAINTAIN A SAFE CONSTRUCTION SITE & ENSURE... | $1,600 | $0 | May 9, 2016 |
| Mar 22, 2016 | 35183578Z | RESOLVE | CLASS - 2 | BC 3307.7 FENCE.NOE: AT TIME OF MY INSPECTION OF A 5STORY BLDG AT BULKHEAD LEVEL, CONSTRUCTION WORK IN PROGRESS. I OB... | $0 | $0 | May 9, 2016 |
| Mar 22, 2016 | 35183575N | RESOLVE | CLASS - 1 | SEC. 3314.4.5.2. USE OF SUPPORTED SCAFFOLD W/O CERTIFICATION. NOTE: ATTHE TIME OF MY INSPECTION OF A 5 STY BLDG AT BU... | $400 | $0 | May 9, 2016 |
| Mar 22, 2016 | 35183577R | RESOLVE | CLASS - 1 | SEC. 3309.10 PROTECTION OF ROOF. NOTE: AT THE TIME OF MY INSPECTION OFA 5 STY BLDG AT BULKHEAD LEVEL,CONSTRUCTION WOR... | $1,600 | $0 | May 9, 2016 |
| Mar 22, 2016 | 35183576P | RESOLVE | CLASS - 1 | BC3314.4.3.5 INSPECTION FOR SUPPORTED SCAFFOLD NOTE: AT TIME OF MY INSPECTION OF A 5 STORY BUILDING AT BULKHEAD LEVEL... | $1,600 | $0 | May 9, 2016 |
| May 1, 2015 | 35129777Y | RESOLVE | CLASS - 1 | SEC. 3314.9.2 FOUNDATION. NOTE: AT THE TIME OF MY INSPECTION RESPONDING TO INCIDENT #19481 WHERE A WORKER GOT PIN IN ... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35103691H | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT. AS NOTED:AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION SIT... | $1,000 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129768M | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION.NOTE: AT TIME OF MY INSPECTION RESPONDING TO INCIDENT #19481 WHE... | $2,400 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129769Y | RESOLVE | CLASS - 1 | BC3301.2 HOLES/OPENING NOT COVERED.NOTE @THE TIME OF MY INSP RESPONDING TO INCIDENT #19481 WHERE A WORKER GOT PIN IN ... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129770L | RESOLVE | CLASS - 1 | BC3309.10 NO PROTECTION FOR ROOF,SKYLIGHT,CHIMNEY ETC.NOTE @THE TIME OF MY INSP RESPONDING TO INCIDENT #19481 WHERE A... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129771N | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. NOTE: AT THE TIME OF MY INSPECTION RESPONDING TO INCIDENT #19481 WHERE A WORKER GOT PIN... | $800 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129772P | RESOLVE | CLASS - 1 | SEC. 33017.2 FIRE EXTINGUISHER AS PER FIRE CODE. NOTE: AT THE TIME RESPONDING TO INCIDENT #19481 WHERE A WORKER GOT P... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129773R | RESOLVE | CLASS - 1 | SEC. 3304.4.5 PLACING OF EQUIPMENT & MATERIAL. NOTE: AT THE TIME OF INSPECTION RESPONDING TO INCIDENT #19481 WHERE A ... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129774Z | RESOLVE | CLASS - 1 | SEC. 3303.4.4 DEBRIS. NOTE: AT THE TIME OF MY INSPECTION RESPONDING TOINCIDENT #19481 WHERE A WORKER GOT PIN IN,BY TR... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129775K | RESOLVE | CLASS - 1 | SEC. 3303.14 DRAINAGE. NOTE: AT THE TIME OF MY INSPECTION RESPONDING TO INCIDENT #19481 WHERE A WORKER GOT PIN IN BY ... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129776M | RESOLVE | CLASS - 1 | SEC. 3303.11.1 REQUIRED LIGHTED STAIRWAY FOR SOFT OR 4 STY STRUCTURE UNDER CONSTRUCTION. NOTE: AT THE TIME OF MY INSP... | $1,600 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129778X | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTE: AT THE TIME OF MY INSPECTION R... | $2,400 | $0 | Feb 2, 2016 |
| May 1, 2015 | 35129779H | RESOLVE | CLASS - 1 | SEC. 3307.6.4.1 CONSTRUCTION OF SIDEWALK SHEDS. NOTE: AT THE TIME OF MY INSPECTION RESPONDING TO INCIDENT #19481 WHER... | $1,600 | $0 | Feb 2, 2016 |
| Mar 11, 2015 | 35121486H | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF INSPECTION NOTED MASONRY WORK... | $2,400 | $0 | Apr 27, 2015 |
| Mar 11, 2015 | 35121487J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. AT TIME OF INSPECTION NOTEDTHAT THERE WAS TRASH BAGS FULL OF GARBAGE @ EXP... | $2,400 | $0 | May 4, 2015 |
| Mar 11, 2015 | 35121488L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN SAFETY EQUIPMENT NO GUARDRAIL @ EXP#1 & #3 PARTIALLY & NO TOE BOARD ENTIRE SITE EXPO #1 & #3 HAS ... | $1,200 | $0 | May 4, 2015 |
| Oct 24, 2014 | 35109355X | RESOLVE | CLASS - 1 | SEC. 3307.3.2 FAILURE TO PROVIDE FENCE AS REQUIRED. NOTE: AT THE TIME OF MY INSPECTIOJ DEMOLITION WORK IN PROGRESS. I... | $1,600 | $0 | Mar 25, 2015 |
| Oct 24, 2014 | 35109354Y | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. NOTE: AT THE TIME OF MY INSPECTION CONSTRUCTION WORK IN PROGRESS. I OBSERVED THAT WORKERS WERE IN ... | $800 | $0 | Mar 23, 2015 |
| Aug 30, 2010 | 34854192Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN PROPERTY WALLS NOTED: REAR & SIDE WALLS AT PROPERTY LINE IN DANGER TO COLLAPSE REAR PART APPR 15F... | $1,000 | $0 | Mar 7, 2011 |