ECB violations
1318 St Marks Avenue, Brooklyn • Block 01363 • Lot 0009
18 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 15, 2019 | 35415665R | RESOLVE | CLASS - 1 | ERECTED/MECHANICAL WORK W/O A PERMIT. AT TIME OF INSPECTOIN IN RESPONSE TO THE AFOREMENTIONED COMPLAINT # IT WAS OBSE... | $0 | $0 | Dec 18, 2019 |
| Jun 23, 2016 | 35125456P | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF MATERIALS DURING CONSTRUCTION OR DEMOLITION.NOTED:@EXP#2 EXCESSIVE DEBRIS,BAGS,BRICKS ON SCAFFOLD&S... | $0 | $0 | Nov 22, 2016 |
| Jun 23, 2016 | 35125473R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED:@TIME OF INSPECTION DUST THROUGHOUT ALL LEVE... | $0 | $0 | Aug 8, 2016 |
| Jun 23, 2016 | 35125470L | RESOLVE | CLASS - 1 | 3314.6.3/3314.10.9 TIEBACKS/LIFELINE.NOTED:@ROOF TIEBACKS TIED OFF TO FIRE ESCAPE GOOSENECK.APP#34035667.REM:COMPLY W... | $0 | $0 | Aug 16, 2016 |
| Jun 23, 2016 | 35181431P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:OBSERVATION HAS BEEN MADE DURING A SAFETY SWEEP DURING A RENOVA... | $0 | $0 | Oct 3, 2016 |
| Jun 23, 2016 | 35202190N | RESOLVE | CLASS - 1 | NON CURRENT CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED. SIDEWALK SHED IS METAL AND COULD BE ENERGIZED. R... | $1,600 | $0 | Dec 19, 2016 |
| Jun 23, 2016 | 35202191P | RESOLVE | CLASS - 2 | FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. NO GFCI PROVIDED FOR SIDEWALK SHED... | $1,200 | $0 | Jan 6, 2017 |
| Jun 23, 2016 | 35202192R | RESOLVE | CLASS - 2 | PVC USED IN SIDEWALK SHED. ALL LIGHTING SHALL BE INSTALLED IN A METAL RACEWAY APPROVED FOR OUTSIDE USE. RMDY: COMPLY ... | $400 | $0 | Jan 6, 2017 |
| Jun 23, 2016 | 35181430N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVATION HAS BEEN MADE DURING A SAFETY SWEEP. IN APT C2 OF AN O... | $1,000 | $0 | Dec 28, 2016 |
| Jun 23, 2016 | 35202193Z | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT.OBSERVED @8AM 6/3 FEEDERS FROM BASEMENT TO ALL APTS.APPLICATION B409086 DOES NOT COVER R... | $800 | $0 | Dec 19, 2016 |
| Jun 23, 2016 | 35125474Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL(S)OR APPURTENANCES.NOTED:WALL @EXP#4 BETWN 1ST&2ND FLRS W.A 4'(APPROX)LONG VERTICAL CRA... | $1,000 | $0 | Dec 5, 2016 |
| Jun 23, 2016 | 35202194K | RESOLVE | CLASS - 2 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS APPLIANCESDEVICES MATERIALS OR WIRING IN USE.8FT FLORESCE... | $0 | $0 | Aug 15, 2016 |
| Jun 23, 2016 | 35125576J | RESOLVE | CLASS - 1 | SMOKING @CONSTRUCTION/DEMOLITION SITE.NOTED:JOB UNDER APPL#321316045,CONSTRUCTION WORKERD OBSERVED SMOKING,AN ACTIVE ... | $2,400 | $0 | Mar 20, 2017 |
| Jun 23, 2016 | 35125469Y | RESOLVE | CLASS - 2 | NO STORAGE ON SHED.NOTED:@EXP#4 DEMOLITION DEBRIS &MATERIALS WERE OBSERVED BEING STORED ON SHED.MULTIPLE BAGS(WHITE)F... | $0 | $0 | Aug 8, 2016 |
| Jun 23, 2016 | 35125472P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTED:MULTIPLE CABLES,EXTENSION CORDS,T... | $0 | $0 | Dec 5, 2016 |
| Jun 23, 2016 | 35125471N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:NO FIRE STOPPING PERBC712.3,27-345.NOTED:EXPOSED CEILINGS,WOOD JOIS... | $1,000 | $0 | Dec 28, 2016 |
| May 27, 2016 | 35125303Y | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W. TENANT PROTECTION PLAN.NOTED:CONTRACTOR IS CURRENTLY WORKING ON ALTERATION TYPE 2 APPLICATION#32... | $1,600 | $0 | Jul 18, 2016 |
| Jan 13, 2016 | 35170747H | RESOLVE | CLASS - 2 | SEC. 3307.6.5 FAILURE TO MAINTAIN SIDEWALK SHED AS REQUIRED BY CODE. AT TIME OF INSPECTION SIDEWALK SHED ERECTED UNDE... | $0 | $0 | Feb 29, 2016 |