ECB violations
401 Schenectady Avenue, Brooklyn • Block 01424 • Lot 0001
19 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 1, 2026 | 39186825X | RESOLVE | CLASS - 2 | MISALINGED CAB MIRROR NYC BUILDING CODE 3001.6). UNGUARDED PLANK SWITCH (2.26). UNSECURE 3RD FLOOR HOISTWAY DOOR LOCK... | $625 | $0 | Jul 8, 2026 |
| Dec 23, 2025 | 39171284K | RESOLVE | CLASS - 2 | UNGUARDED PLANK SWITCH. MISALINGED CAB MIRROR. BOUNCE IN WORM AND GEAR. ADJUST FLOOR STOPS. PROVIDE KEYS TO ROOF/GOVE... | $0 | $0 | Mar 4, 2026 |
| Oct 27, 2025 | 39164873N | RESOLVE | CLASS - 1 | CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 2 ITEMS: MISALINGED CAB MIRROR. ADJUST SELECTOR TAPE SWITCH. ... | $1,250 | $0 | Jan 7, 2026 |
| Jul 25, 2025 | 39155001L | RESOLVE | CLASS - 1 | CLASS 1: CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. R... | $1,250 | $0 | Oct 1, 2025 |
| Nov 29, 2023 | 39100265R | RESOLVE | CLASS - 2 | CATEGORY 1 TEST PAT DUE (07/2022), PERFORM CATEGORY 1 TEST AND PROVIDEAN UPDATED CAT 1 TAG FOR THE CONTROLLER. UNAUTH... | $625 | $0 | Jul 8, 2024 |
| Sep 28, 2022 | 39070971J | RESOLVE | CLASS - 2 | CLASS 2: 2.X.10 PHONE INOPERATIVE REPAIR & PROGRAM TO 24 HR EMERGENCY OPERATOR. 8.V.1 ELEVATOR NOT LEVEL WITH LANDING... | $625 | $0 | Feb 1, 2023 |
| Jul 13, 2022 | 39065745P | RESOLVE | CLASS - 1 | CEASE USE ITEM; CAR FAILED TO GO ON SAFETY DURING CATEGORY 5 TEST. CLASS 1 ITEM; DLM IMPROPERLY INSTALLED ON THIS DEV... | $0 | $0 | Feb 6, 2023 |
| Mar 10, 2022 | 39057769J | ACTIVE | CLASS - 1 | DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS' SERVICE PRESENT IN CONTROLLER. INSTALL FIREMANS' SERVICE SO DLM... | $1,250 | $0 | Sep 14, 2022 |
| Jan 12, 2022 | 39054303Y | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Jun 22, 2022 |
| May 27, 2021 | 39041857N | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Mar 2, 2022 |
| Feb 26, 2020 | 39018322L | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $0 | $0 | Jul 9, 2021 |
| Jul 14, 2008 | 34687212R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. AT 1ST FLR LEVEL STORAGE AR... | $1,000 | $0 | Dec 8, 2008 |
| Nov 13, 2007 | 38179212L | RESOLVE | Hazardous | CEASE USE.21L10,21I11,16E10,14A11,15I11,71K10,41A01,38O02,71O02,34Q03,51H14,51A07,60I11,60T07,59L11.21-L SHAKING GF H... | $500 | $0 | Apr 28, 2008 |
| Aug 5, 2006 | 38160723N | RESOLVE | Non-Hazardous | 15M07/08V01/12Q07/66O02/38O02/16R09/59B07/84T07 15-PROVIDE CERT FRAME 08-ADJ FL STOPS DOWN DIRECTION& LOBBY UP DIRECT... | $0 | $0 | Sep 18, 2006 |
| Sep 27, 2000 | 34265620X | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG: EXTERIOR REAR RETAINING WALL APPROX 6' IN HEIGH AT REAR OF BLDG HAS DEFECTIVE CEMENT STUCCO... | $0 | $0 | Dec 18, 2000 |
| Feb 14, 2000 | 34242328R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING.DEFECTS ARE:SLATE TILES AT ORNAMENTAL ROOF FACADE ARE BROKEN AND HANGING,AT FRONT AND SI... | $800 | $0 | Apr 3, 2000 |
| Aug 14, 1998 | 32016173N | RESOLVE | Non-Hazardous | 49-OWNER AGENT REFUSED ACCESS TO INSPECT BOILER AS SCHEDULE. | $0 | $0 | Oct 26, 1998 |
| Mar 17, 1998 | 38071510P | RESOLVE | Non-Hazardous | 75U5,60J10,18B1,17I11,57O2,33Q3. 75-PERFORM 5 YEAR TEST & TAG. 60-CWTBUFFER. 17-CAR VIS PANEL. 33-INSTALL OVERHEAD DOOR. | $180 | $0 | Nov 23, 1998 |
| Apr 27, 1994 | 32012548M | RESOLVE | Non-Hazardous | 32A, 33A, 48B 32-BX- CABLE ON FLOOR, NOT PROPERLY HUNG AND SECURED. | $350 | $0 | Jul 11, 1994 |