| Dec 6, 2019 | 39014004H | RESOLVE | CLASS - 2 | FRONT FLAME SIGHT GLASS DEFECTIVE-SPILL SWITCH DEFECTIVE-GAS PIOLIT IS NOT HARD PIPED TO REGULATOR-BOILER ROOM LIGHTS... | $655 | $0 | Aug 20, 2020 |
| Nov 19, 2019 | 35461310P | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. IN APT#21,CREATED FULL HEIGHT PARTITION W/DOOR SEPERATING A ROOM & DIMISHING ACCESS TO THE FIRE ES... | $0 | $0 | Nov 19, 2020 |
| May 17, 2018 | 37009809X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION# 35236856X ISSUED ON 8/31/17 & TO FILE A C O... | $625 | $0 | Oct 15, 2018 |
| Aug 31, 2017 | 35236856X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES/RETAINING WALL FOUND @ EXPOSURE#3/REAR YARD CONCRETE RETAINING WA... | $500 | $0 | Oct 23, 2017 |
| Jul 19, 2016 | 32076940J | RESOLVE | CLASS - 2 | B254,50,51. 50-WRONG FLUE MATERIAL FROM BOILER TO CHIMNEY. NEEDS PROPER FLUE MATERIAL. | $2,500 | $0 | Sep 12, 2016 |
| Dec 14, 2015 | 35142108N | RESOLVE | CLASS - 1 | WORK WITHOUT PERMIT.WORK NOTED:OBSERVED AT 1:15PM IN APT. #1 BEHIND GAS STOVE A NEW GAS LINE RAN TO A GAS STOVE,WITH ... | $8,000 | $0 | Feb 1, 2016 |
| Dec 8, 2015 | 35164184M | RESOLVE | CLASS - 3 | WORK W/O PERMIT.APT 21 SUBDIVIDED LIVING RM W/ FULL HEIGHT PARITION & A DOOR CREATING ADDITIONAL BEDRM.REM:COMPLY W/ ... | $500 | $0 | Feb 1, 2016 |
| Mar 18, 2011 | 32070348N | RESOLVE | CLASS - 2 | B254 3A 15 16 32A 38 40 48A 50A 50B 50C 50D. 50A-SOOT ON BOILER. 50B-DEBRIS AROUND BOILER. 50C-MUST BRACE DISCHARGE O... | $500 | $0 | Aug 15, 2011 |
| Feb 19, 2011 | 32070360X | RESOLVE | CLASS - 2 | 32A,32B,50ABCDEFGH 50A-FLUE PIPE NOT PROPERLY SEALED TO CHIMNEY 50B-FLUE PIPE NEED SUPPORT 50C-BOILER ROOM DOOR DEFEC... | $500 | $0 | Aug 15, 2011 |
| Feb 19, 2011 | 32070361H | RESOLVE | CLASS - 2 | 50A,50B 50A-WORK W/O A PERMIT 28-105.1 50B-NO WORK PERMIT FILED WITH DOB FOR THE NEW GAS LINE AND THE GAS FIRED BOILER. | $800 | $0 | Aug 15, 2011 |
| Feb 23, 2009 | 34738319Y | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN WITNESSED BREECHING OF BOILER NOT SUPPORTED. EXPOSED WIRING MISSING ANTISPHON VALVE AND FIREOMATI... | $200 | $0 | Apr 20, 2009 |
| Aug 7, 2000 | 32020026P | RESOLVE | Non-Hazardous | 49/ A DEFECTIVE BACKFLOW PREVENTOR | $0 | $0 | Sep 25, 2000 |
| Aug 5, 2000 | 32019174Z | RESOLVE | Hazardous | 32A 49 51 (9) BOILER IN OPERATION WITHOUT SAFETY RELIEF VALVE (B)BACKFLOW PREVENTOR IS DEFECTIVE REPORTED TO HPD COMP... | $800 | $0 | Dec 11, 2000 |