ECB violations
152 Sackman Street, Brooklyn • Block 01443 • Lot 0139
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 16, 2019 | 35448622H | RESOLVE | CLASS - 2 | 3301.2=UNSAFE EQUIPMENT AND MATEIRLA AT THE TIME OF INSPECTION IOBSEVRED AT EXPOSURE 2 (DEAN STREET ) A PARTIAL UNPOR... | $625 | $0 | Jul 2, 2021 |
| Apr 8, 2019 | 35404650K | RESOLVE | CLASS - 1 | 3307.1 PEDESTRIANS SHALL BE PROTECTED DURING CONSTRUCTION AS REQUIRED BY THIS SECTION DEPT OF TRANSPORTATION. NOTES:A... | $6,250 | $6,250 | Jul 22, 2019 |
| Mar 31, 2017 | 35237645K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN SIDWALK SHED LIGHTING IN CODE COMPLIANT MANNER.NOTE:AT TIME OF INSPECTION I OBSERVED SIDEWALK SHE... | $800 | $0 | Aug 21, 2017 |
| Mar 8, 2017 | 35201486H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. AS NOTED AT TIME OF INSPECTION ON ACTIV... | $500 | $0 | Jun 26, 2017 |
| Mar 8, 2017 | 35201487J | RESOLVE | CLASS - 2 | BC3301.7 FAILURE TO PROVIDE P.E. APPROVED DESIGN DRAWNINGS.AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION ... | $500 | $0 | Nov 1, 2017 |
| Dec 27, 2016 | 35201267H | RESOLVE | CLASS - 1 | BC3301.7/FAILURE TO PROVIDE P.E. APPROVED DESIGN DRAWINGS AS NOTED:AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SI... | $1,000 | $0 | Aug 16, 2017 |
| Dec 27, 2016 | 35201265Y | RESOLVE | CLASS - 2 | FORMS FILED WITH DEPT OF BLDG DO NOT HAVE REQUIRED SIGNATURES AS NOTEDAT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION... | $800 | $0 | Aug 2, 2017 |
| Dec 27, 2016 | 35201266X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.AS NOTED;AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE OBSERVE... | $4,800 | $0 | Aug 16, 2017 |
| Mar 1, 2016 | 35157091H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION. OBSERVED OPEN & UNSECURED JOBSITE. THERE WERE O... | $1,200 | $0 | Aug 15, 2016 |
| Mar 1, 2016 | 35157093L | RESOLVE | CLASS - 2 | SEC. 3304.4.4 FAILURE TO 3 FOOT 6IN GUARDRAIL OR SOLID ENCLOSURE AROUND OPEN & ACCESSIBLE SIDES OF EXCAVATION. FAILUR... | $800 | $0 | Aug 19, 2016 |
| Mar 1, 2016 | 35157094N | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DOB W/I 24-48HRS OF THE START OF EXCAVATION. EXCAVATION WAS DONE FOR CONSTRUCTION OF ONE BLDG F... | $1,200 | $0 | Aug 19, 2016 |
| Jul 22, 2005 | 34482745K | RESOLVE | Hazardous | FAILURE TO MAINTAINS DEFECTIVE LOOSE BRICKS AT FACADES SIDE & REAR BROKEN WINDOWS & SECTION OF ROOF MISSING REMEDY:MA... | $10,000 | $0 | Sep 12, 2005 |
| Mar 30, 2005 | 34473550X | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING. DEFECT ARE: BRICKS ARE CRUMBLING AT BLDGREAR EXTENSION AT PARAPET LOCATION. (2) SECTION... | $2,500 | $0 | May 16, 2005 |
| Jun 22, 2001 | 34298959X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT IS: BROKEN LOOSE AND NOT CONECT TO STORM RAIN DOLLEN SPOUT AT EAST CENTER. SUGGESTED REMED... | $2,500 | $0 | Aug 6, 2001 |