Maintenance code violations
1804 St Johns Place, Brooklyn • Block 01474 • Lot 0033
97 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Dec 24, 2025 | B | NOV SENT OUT | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 2,... | 2 | Jan 28, 2026 |
| Dec 24, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 2 | Jan 7, 2026 |
| Dec 24, 2025 | B | NOV CERTIFIED LATE | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE ... | 2 | Jan 28, 2026 |
| Nov 26, 2025 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1... | 2 | Nov 26, 2025 |
| Nov 26, 2025 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT CELLER AT BOILER ROOM | — | Dec 2, 2025 |
| Sep 10, 2025 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCKING DEVICE ON DOOR IN THE ENTRANCE LOCA... | 3 | Oct 15, 2025 |
| Sep 10, 2025 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd S... | 3 | Oct 6, 2025 |
| Sep 10, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 3 | Oct 15, 2025 |
| Sep 10, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 3 | Oct 15, 2025 |
| Sep 10, 2025 | C | NOV SENT OUT | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 3 | Sep 24, 2025 |
| Sep 16, 2024 | C | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT ALL HOT WATER FIXTURES IN THE ENTIRE APAR... | 2 | Sep 22, 2024 |
| Sep 16, 2024 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2 | Oct 12, 2024 |
| Apr 11, 2024 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 15, 2024 |
| Aug 11, 2022 | A | VIOLATION DISMISSED | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CERAMIC TILES SURFACE WITH GROUTED JOINTS/CAULK... | 2 | Nov 14, 2022 |
| Aug 11, 2022 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2 | Sep 15, 2022 |
| Aug 11, 2022 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY... | 2 | Sep 15, 2022 |
| Aug 11, 2022 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Sep 6, 2022 |
| Aug 11, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED ON ENTRANCE DOOR AT ROO... | 2 | Sep 15, 2022 |
| Mar 2, 2022 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jun 5, 2022 |
| Feb 15, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE 2nd ROOM FROM ... | APT2 | Mar 22, 2022 |
| Feb 9, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 2 SQ FT MOLD AT CEILING IN... | 2 | Mar 16, 2022 |
| Oct 18, 2021 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WAL... | APT2 | Nov 22, 2021 |
| Oct 18, 2021 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | APT2 | Nov 22, 2021 |
| Oct 18, 2021 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE 2nd ROOM FROM ... | APT2 | Jan 21, 2022 |
| Oct 18, 2021 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT APT2, 2nd STOR... | APT2 | Nov 22, 2021 |
| Oct 12, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EXTRACT CEILING FAN IN THE KITCHEN LOCATED AT APT 2, 2nd S... | 2 | Nov 16, 2021 |
| Oct 12, 2021 | A | VIOLATION DISMISSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Jan 15, 2022 |
| Oct 12, 2021 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE 3rd ROOM ... | 2 | Nov 16, 2021 |
| Oct 12, 2021 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Nov 7, 2021 |
| Oct 12, 2021 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Nov 7, 2021 |
| Oct 12, 2021 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2 | Nov 16, 2021 |
| Oct 12, 2021 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY... | 2 | Nov 16, 2021 |
| Oct 12, 2021 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 2 SQ FT MOLD AT CEILING IN... | 2 | Jan 15, 2022 |
| Oct 12, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH AND EAST W... | 2 | Nov 16, 2021 |
| Feb 18, 2021 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | May 24, 2021 |
| Feb 16, 2021 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1... | 2 | Feb 15, 2021 |
| Feb 16, 2021 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd... | 2 | Feb 15, 2021 |
| Oct 13, 2020 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Nov 8, 2020 |
| Oct 13, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK IN THE ENTRANCE LOCATED AT APT 2, 2nd STORY, 1st... | 2 | Nov 17, 2020 |
| Oct 13, 2020 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2 | Nov 17, 2020 |
| Oct 13, 2020 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, ... | 2 | Nov 17, 2020 |
| Oct 13, 2020 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Nov 8, 2020 |
| Oct 13, 2020 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Nov 17, 2020 |
| Oct 13, 2020 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2 | Nov 8, 2020 |
| Jun 22, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4... | 3 | Jul 27, 2020 |
| Jun 22, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 4th ROOM FROM NORTH AT WEST LOCATED A... | 3 | Jul 27, 2020 |
| Jun 12, 2020 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 3, 3rd STORY, AP... | 3 | Jul 17, 2020 |
| Jun 12, 2020 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Sep 15, 2020 |
| Jun 12, 2020 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 3, 3rd STORY, APARTMENT AT EAST | 3 | Jul 17, 2020 |
| Jun 1, 2020 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT ... | — | Jul 6, 2020 |