Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 2, 2023 35674450X RESOLVE CLASS - 1 3304.8/3304.14.2 FAILURE TO DRAW CONSTRUCTION SITE OF STANDING WATER AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOB... $2,500 $0 Oct 11, 2023
Aug 2, 2023 35674199P RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO GUARDRAILS. AS NOTED: AT TIME ... $625 $0 Oct 11, 2023
Mar 28, 2023 39514734K RESOLVE CLASS - 2 ATOI I OBSERVED A PROPOSED 6 STORY NEW BUILDING WITH AN INSTALLED SIDEWALK SHED AT EXPOSURE 1. I OBSERVED THAT THE SW... $0 $0 Apr 15, 2024
Feb 24, 2023 39513524H RESOLVE CLASS - 1 INSPECTION OF AN 6 STORY BUILDING WITH WORK IN PRGRESS, OBSERVED AT ELEVATOR SHAFT A SUPPORT SCAFFOLD APPROXIMATELY 5... $0 $0 Jan 30, 2026
Feb 24, 2023 39513523X RESOLVE CLASS - 1 INSPECTION OF AN 6 STORY BUILDING AT 5 FLOOR LEVEL, OBSERVED AT EXPOSURE ONE WORKER HAVE DUGOUT OPEN BETWEEN SIDEWALK... $0 $0 Jan 30, 2026
Oct 19, 2022 39507883Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN SUPER LOG, FAIL TO ASSIGN COMPETE PERSON FOR EACH JOB SITE FOR NB 340771720 AND NB 340770473. FAI... $2,500 $0 Jun 12, 2023
Oct 19, 2022 39507875Z RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING AT 2ND FLOOR LEVEL, GENERAL CONTRACTOR LICENSE PERMIT #616452 HAS ... $2,500 $0 Jun 12, 2023
Oct 19, 2022 39507876K RESOLVE CLASS - 1 FAILURE TO PROVIDE BARRIERS FOR WORK OR STORAGE ZONE BC3303.4.7. @6 STORY BUILDING AT 2ND FLOOR LEVEL I OBSERVE CONST... $625 $0 Jun 12, 2023
Oct 19, 2022 39507879X RESOLVE CLASS - 2 AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING AT 2ND FLOOR LEVEL, I OBSERVED CONSTRUCTION OPERATION APPROXIMATEL... $625 $0 Jun 12, 2023
Jun 28, 2022 39502808X RESOLVE CLASS - 2 SLOPE OF EXCAVATION I OBSERVED ACTIVE SITE AT FOUNDATION PHASE. AT EXP1 NEAR EXP2, I OBSERVED OVER 5F DEEP EXCAVATED ... $0 $0 Nov 2, 2022
Jun 28, 2022 39502807Y RESOLVE CLASS - 1 INADEQUATE SSP I OBSERVED ACTIVE JOBSITE AT FOUNDATION PHASE. UPON REQUEST TO VIEW THE SITE SAFETY PLAN(SSP),I OBSERV... $625 $0 Jun 26, 2023
Jun 28, 2022 39502806M RESOLVE CLASS - 1 NO FENCE OR CCD1(3307.7) I OBSERVED ACTIVE JOBSITE AT FOUNDATION PHASE WITH NO FENCE AT EXP4. UPON REQUEST FOR PERMIS... $500 $0 Jun 26, 2023
Jun 14, 2022 35641192L RESOLVE CLASS - 2 FAILURE TO MAINTAIN(REBAR CAPS)NOTE:AT TIME OF INSPECTION OF ACTIVE 6-STORY NEW BUILDING JOBSITE OBSERVED WORKERS WOR... $0 $0 Nov 9, 2022
Jun 14, 2022 39502241Y RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED MISSING FENCE AT EXPO# 4 CREATING POTENTIAL SAFETY HAZZARD CONDITION FOR ADJOINING OCC... $0 $0 Oct 19, 2022