Willoughby Avenue, Brooklyn
Brooklyn • Block 01588 • Lot 0001 • Zip: 11206
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 5 days ago- Downtown Brooklyn 31 min 13 walking, 18 riding
- Fulton Street 36 min 13 walking, 23 riding
- Union Square 37 min 13 walking, 24 riding
- Grand Central 44 min 13 walking, 31 riding
- Times Square 47 min 13 walking, 34 riding
- Penn Station 48 min 13 walking, 35 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Sal & Cookie’s Ultra Fine Diner
No description yet
Mao Mao
No description yet
Formosa
No description yet
Boyfriend Co-Op
No description yet
Petisco Brazuca
No description yet
Indika House
No description yet
Sonbul - Korean Cafe and Kitchen
Sonbul - Korean Cafe and Kitchen is a cozy and inviting restaurant in Brooklyn, NY, serving up authentic Korean dishe...
BKLYN BLEND
Juices, shakes & elevated sandwiches are offered in a chill, rustic-chic space with Wi-Fi.
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
Alteration Type I
PROPOSED ALTERATION TYPE I (NO WORK) FOR THE EXISTING BUILDING (A&C)ON TAX LOT 1. THIS APPLICATION IS RELATED TO ...
-
HPD violation May 26, 2026
Class B
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQUARE FEET AT S...
-
HPD violation May 26, 2026
Class B
§ 27-2005 HMC: REFIT CLOSET DOOR AT EAST WALL. IN THE PRIVATE HALLWAY LOCATED AT APT 6R, 6th STORY, 3rd APARTMENT FR...
-
Alteration Type I
PROPOSED ALTERATION TYPE I (NO WORK) FOR THE EXISTING BUILDINGS B&D ON TAX LOT 1. THIS APPLICATION IS RELATED TO ...
-
Subdivision Improved
-
HPD violation May 6, 2026
Class C
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6R, 6th STO...
-
HPD violation May 6, 2026
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
-
HPD violation May 6, 2026
Class C
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6R, 6th ...
-
HPD violation May 5, 2026
Class B
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LEDD THAN 10 SQ FT AT CEILING IN...
2024
-
DOB violation Dec 1, 2024
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
DOB violation Sep 23, 2024
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Sep 23, 2024
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
2023
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL HGH PRESSURE INSPECTION
2022
-
CLASS - 2
WORK W/O PERMIT.ON 12/27/22 OBSERVED WORK BEING PERFORMED ON EXP #3(EAST ELEVATION)ON SUSPENDED SCAFFOLD WITH NO VISI...
-
CLASS - 1
FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SHED NETTING ETC WHERE REQUIRED TO PROTECT & SECURE PUBLIC SAFETY...
-
CLASS - 1
CEASE USE ITEM: ROPE GRIPPER DOES NOT ENGAGE WHEN UNINTENDED MOVEMENT IS TESTED. 125 %WEIGHTS REQUIRED FOR REINSPECTI...
-
CLASS - 1
CEASE USE ITEM: ROPE GRIPPER DOES NOT ENGAGE WHEN UNINTENDED MOVEMENT IS TESTED. 125 %WEIGHTS REQUIRED FOR REINSPECTI...
2021
-
CLASS - 2
DOMESTIC HW BOILER = POOR FLAME ÝNOISE AND VIBRATION¨/VALVE LEAKING ABOVE; CORRECT VIOLATION AND SUBMIT THE CERTIFICA...
-
CLASS - 2
DEBRIS LEFT IN BOILER ROOM; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION
2018
-
Alteration Type II
REPLACE (2) DIRECT VENTED GAS BOILERS AND (2) HOT WATER STORAGE TANKS.
2016
-
Alteration Type III
INSTALLATION OF TEMPORARY PIPE SCAFFOLD FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
Alteration Type III
INSTALLATION OF TEMPORARY PIPE SCAFFOLD FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2015
2014
2012
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records