DOB violations
225 Mac Donough Street, Brooklyn • Block 01669 • Lot 0070
31 records
Violations issued by the Department of Buildings.
| Issued | Violation | Type | Category | Description | Disposed |
|---|---|---|---|---|---|
| Apr 16, 2025 | SR0302RF | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION, I OBSERVED ON EXPOSURE #1 SOUTH ELEVATI... | — |
| Oct 29, 2024 | SR0301NS | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED SPALLED BROWN STONE AT 1 FLOOR.MISSING WINDOW AT 2ND A... | — |
| Jan 19, 2024 | SR0301RF | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | .FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT TIME OF INSPECTION OBSERVED ON EXPOSURE#4 EAST ELEVATION DA... | — |
| Mar 13, 2023 | SR0304DJ | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | B204 FTM BUILDING WALLS OR APPURTENANCES. OBSERRVED ON EXP1 BLDG NETTING IS LOOSE AND NOT SECURED PROPERLY. REMEDY: M... | — |
| Sep 14, 2022 | 00056 | COMPBLD-STRUCTURALLY COMPROMISED BUILDING NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISED BLDG. | — |
| Aug 8, 2022 | LL0306RF | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FTM BUILDING IN CODE COMPLIANT MANNER-BUILDING FACADE HAS HAZARDOUS CONDITION ON EXP1 SUCH AS: OPEN HORIZONTAL CRACK ... | — |
| May 31, 2022 | 16959 | EGNCY-EMERGENCY NONE | V-DOB VIOLATION - ACTIVE | REMOVE ENTIRE FRONT WALL DOWN TO 2ND FLOOR LEVEL & INSTALL TEMPORARY WEATHERPROOF WALL | — |
| May 27, 2022 | LL30302JC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FTM BLDG IN CODE COMPLIANT MANNER. BUILDING FACADE IS IN A STATE OF DISREPAIR. CONDITIONS INCLUDE OPEN WINDOW FRAMES,... | — |
| May 25, 2022 | 16952 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V-DOB VIOLATION - ACTIVE | INSTALL NEW APPROX 30 FT W X 15 FT D SIDEWALK SHED IN FRONT YARD OF 225 WITH APPROX.5FT OVERHANGS ONTO ADJACENT PROPE... | — |
| Sep 2, 2020 | 03600 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Sep 2, 2020 | 03604 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Sep 2, 2020 | 03603 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Sep 2, 2020 | 03602 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Sep 2, 2020 | 03601 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Nov 15, 2018 | 19-0181 | LANDMK-LANDMARK NONE | V-DOB VIOLATION - ACTIVE | — | — |
| Nov 13, 2018 | FEU31202BS | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | COMPLY WITH COMMISSIONER ORDER #333879 IMMEDIATELY | — |
| Nov 13, 2018 | FEU31201BS | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | COMPLY WITH COMMISSIONER ORDER #333878 IMMEDIATELY | — |
| Feb 21, 2018 | FEU30302BS | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FTM FRONT EXP1 WALL&EXP4 WALL.PREM IS 3ST+B,ATTACH,2 FAM FRAMED W/WOOD JOISTS&BRICK EXT WALLS.FRONT EXP1 WALL IN DISR... | — |
| Feb 21, 2018 | FEU30301BS | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FTM DUE TO 2 ALARM FIRE 2/13/18.PREM IS 3ST+B,ATTACH,2 FAM FRAMED W/ WOOD JOIST&BRICK EXT WALLS.MODERATE TO SEVERE FI... | — |
| Feb 16, 2018 | 11115 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V-DOB VIOLATION - ACTIVE | INSTALL INTERIOR SHORING & BRACING BY LIC P.E.AT REAR APPROX.20FT W BY 15FT D AREA OF 3RD FLOOR AND ROOF TO ALLOW FIR... | — |
| Feb 14, 2018 | 3386/18 | UB-UNSAFE BUILDINGS NONE | V-DOB VIOLATION - ACTIVE | — | — |
| Feb 13, 2018 | CNE01SC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | DUE TO FIRE | — |
| Oct 4, 2017 | 00213 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Aug 9, 2017 | 00337 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | Oct 20, 2017 |
| Aug 9, 2017 | 00336 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Mar 7, 2012 | 00171 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| Apr 6, 2011 | 00194 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V-DOB VIOLATION - ACTIVE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | — |
| May 10, 2001 | 03MC02 | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | HAZARDOUS | — |
| May 10, 2001 | 03MC05 | C-CONSTRUCTION OTHER OPTIONAL | VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE | WORK WITHOUT A PERMIT. WORK NOTED: SIDEWALK SHED ERECTED AT FRONT OF PREMISES REMEDY: OBTAIN A PERMIT | — |
| Mar 30, 1999 | 131/99 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V-DOB VIOLATION - ACTIVE | — | — |
| Feb 9, 1999 | 03T02 | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | HAZARDOUS | — |