ECB violations

519 Marcy Avenue, Brooklyn • Block 01739 • Lot 0006

72 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 2, 2026 39191275R ACTIVE CLASS - 2 APT#2H CO DETECTOR REMOVED+APT#2E SAFETY VALVE LEAKING+NOT PIPED DOWN+APT#1B BOTH SAFETY VALVES+BACKFLOW NOT PIPED DO... $1,250 $1,250 Aug 19, 2026
Jun 2, 2026 39190730P ACTIVE CLASS - 1 CLASS 1: DOOR LOCK MONITORING FEATURE MALFUNCTIONING - CAR SIDE/DOOR CONTACT NOT OPERATING AS REQUIRED AS PER ASME A1... $1,250 $1,250 Aug 12, 2026
Jun 2, 2026 39191268Z ACTIVE CLASS - 2 APT#3A RELIEF VALVE+BACKFLOW NOT PIPED DOWN+APT#3B CO DETECTOR DEFECTIVE+SAFETY VALVE NOT PIPED DOWN+APT#3E NO NEUTRA... $1,250 $1,250 Aug 19, 2026
Jun 2, 2026 39191237X ACTIVE CLASS - 2 APT#9D BOSH BOILER HAS NO CONDENSATE NEUTRALIZER+APT#8B BOILER SAFETY IS NOT PIPED DOWN+APT#7E BOILER RELIEF VALVE NO... $1,250 $1,250 Aug 19, 2026
Jun 2, 2026 39191243M ACTIVE CLASS - 3 APT#5B NO NEUTRALIZER+RELIEF VALVE NOT PIPED DOWN+APT#5D NO SAFETY DISCHARGE PIPE+APT#5C BACKFLOW NOT PIPED DOWN+APT#... $500 $500 Aug 19, 2026
Jul 3, 2025 39152773H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... $2,530 $2,530 Feb 25, 2027
Jul 3, 2025 39152772X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8 (2014 C... $2,530 $2,530 Feb 25, 2027
Apr 19, 2024 38274661M RESOLVE CLASS - 1 6-X-17, 59-B-5. DOOR LOCK MONITORING NOT WORKING TAMPERED WITH DISABLED. THIS IS A SAFETY FEATURE TO SENSURE PASSENGE... $1,250 $0 Jun 26, 2024
Apr 18, 2024 39112039R RESOLVE CLASS - 2 OBSERVED ON THE 2ND FL IN THE MECH ROOM OBSTRUCTED SPRINKLER HEAD. ALSO IN THE SPRINKLER CONTROL ROOM LOCATED ON THE ... $0 $0 Jun 26, 2024
Apr 18, 2024 39112038P RESOLVE CLASS - 2 OBSERVED IN THE GAS METER ROOM LOCATED IN THE BASEMENT/CELLAR EXCESSIVE AMOUNTS OF COMBUSTIBLE STORAGE( FILES,CLEANIN... $0 $0 Jun 26, 2024
Jan 10, 2024 39103181N RESOLVE CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39078080M ISSUED ON 01/... $2,500 $2,500 Jan 13, 2025
Jan 20, 2023 39078070Z RESOLVE CLASS - 2 OBSERVED: FROM FIRST FL TO 9TH FLOOR, CORRIDORS, MECHANICAL ROOMS, VARIOUS DAMAGES DUE TO WATER LEAKS, CONDENSATION C... $625 $0 Jan 2, 2024
Jan 20, 2023 39078071K RESOLVE CLASS - 2 OBSERVED: OM FIRST FL TO 9TH FLOOR, STAIR CASE A& B, EXIT DOORS, MAIN ENTRANCE DOORS, EXIT DOOR MARCY AV, DO NOT CLOS... $312 $0 Jan 2, 2024
Jan 20, 2023 39078069L RESOLVE CLASS - 2 OBSERVED: THROUGHOUT THE BUILDING, MECHANICAL ROOMS FROM FIRST FL TO 9TH FL, CELLAR LEVEL, ELECTRICAL/GAS METER ROOM ... $1,250 $0 Jan 2, 2024
Jan 20, 2023 39078068J RESOLVE CLASS - 2 OBSERVED: AT CELLAR LEVEL, TWO ROOMS WERE CREATED AND DO NOT MEET TECHNICAL AND FIRE RATED SPECIFICATIONS. ALSO. WALL... $625 $0 Jan 2, 2024
Jan 20, 2023 39078062Z ACTIVE CLASS - 2 OBSERVED THROUGHOUT BUILDING NO VENTILATION OR GAS DETECTION SYSTEM FOR THE MECHANICAL ROOMS IN THE PUBLIC CORRIDORS.... $625 $625 Jun 6, 2024
Jan 20, 2023 39078080M RESOLVE CLASS - 1 I OBSERVED IN THE BASEMENT AREA UNDER THE STAIRS IN THE ELECTRICAL AREA. THE INSTALLATION OF THE POWER CORDS FOR THE ... $1,600 $0 Nov 14, 2024
Jan 20, 2023 39078072M RESOLVE CLASS - 2 OBSERVED: THROUGHOUT THE BUILDING, MECHANICAL ROOMS FROM FIRST FL TO 9TH FL, CELLING DAMAGES, SEVERAL OPENING AND MIS... $625 $0 Jan 2, 2024
Jan 20, 2023 39078079P RESOLVE CLASS - 2 I OBSERVED ON ALL FLOORS THE DISCONNECTION AND REINSTALLATION OF ELECTRICAL WIRING FOR NEWLY INSTALLED BOILER/WATER H... $800 $0 Jan 2, 2024
Jan 20, 2023 39078081Y RESOLVE CLASS - 2 I OBSERVED IN THE MECHANICAL ROOMS ON ALL FLOORS, THE FAILURE TO SUPPORT/ SECURE THE BX CABLING SUPPLYING POWER TO TH... $800 $0 Jan 2, 2024
Jan 20, 2023 39078063K RESOLVE CLASS - 2 OBSERVED ON THE 5TH FLOOR SPRINKLER HEADS ARE OBSTRUCTED IN THE PUBLIC CORRIDOR., REPAIR AND/OR REPLACE $312 $0 Jan 2, 2024
Jan 20, 2023 39078078N RESOLVE CLASS - 2 I OBSERVED IN THE WATER HEATER/ BOILER ROOM, THE UNPERMITTED USE OF FLEXIBLE CORDS AS PER EC 400.8 PERMANENT WIRING S... $800 $0 Jan 2, 2024
Jan 20, 2023 39078064M RESOLVE CLASS - 2 OBSERVED IN BASEMENT/CELLAR LEVEL EXTREMELY RUSTED AND CORRODED GAS PIPING. AS PER FGC 403.8 PROTECTIVE COATING. WHER... $625 $0 Jan 2, 2024
Jan 20, 2023 39078067H RESOLVE CLASS - 2 OBSERVED: AT ROOF LEVEL, PARAPET WALLS CRACKED IN DIFFERENT LOCATIONS, MAINTAIN EXTERIOR BUILDING WALL $625 $0 Jan 2, 2024
Mar 5, 2020 39018993M RESOLVE CLASS - 3 NOTED: OBSERVED AT STAIR "A" BULKHEAD, A HOLE, SPALLING AND MISSING PLASTER AROUND THE INTERIOR OF THE ROOF'S SKYLIGH... $250 $0 Sep 21, 2020
Mar 5, 2020 39019006Y RESOLVE CLASS - 2 I OBSERVED THE VIOLATING CONDITIONS AS STATED IN ECB # 39007721P ISSUED ON 08/14/2019 STILL IN EFFECT. NO C OF C FILE... $1,250 $0 Sep 21, 2020
Mar 5, 2020 39019005M RESOLVE CLASS - 2 I OBSERVED THE VIOLATING CONDITIONS AS STATED IN ECB #39007719X ISSUED ON 08/14/2019 STILL IN EFFECT AND NO C OF C SU... $1,250 $0 Sep 21, 2020
Mar 5, 2020 39018995X RESOLVE CLASS - 1 NOTED: OBSERVED AT CELLAR LEVEL STAIR "B", FIRE RATED PARTITIONS HAVE BEEN REMOVED FROM AROUND THE STAIRWELL AND ADJO... $1,250 $0 Sep 21, 2020
Mar 5, 2020 39018994Y RESOLVE CLASS - 2 NOTED: OBSERVED EXTERIOR STAIRS AT NORTHWEST ELEVATION NEXT TO THE RAMP, STEEL RISERS ARE CORRODED WITH HOLES AND CEM... $625 $0 Sep 21, 2020
Mar 5, 2020 39019003Z RESOLVE CLASS - 1 I OBSERVED THROUGHOUT THE BASEMENT OFFICES, RECREATION AREAS, MAINTENANCE ROOMS, AND MECHANICAL ROOMS THE IMPROPER TE... $4,000 $0 Feb 19, 2021
Mar 5, 2020 39019004K RESOLVE CLASS - 1 I OBSERVED IN THE WATER METER ROOM THE GROUNDING CONDUCTOR UNSUPPORTED AND LAYING ON THE FLOOR UNDER STEEL SUPPORTS A... $12,000 $0 Feb 19, 2021
Aug 14, 2019 39007721P RESOLVE CLASS - 1 I OBSERVED THE IMPROPER INSTALLATION OF THE GROUND ELECTRODE CONDUCTOR THE ECG WAS LAYING ON THE FLOOR OF THE SPRINKL... $4,800 $0 Jan 10, 2020
Aug 14, 2019 39007719X RESOLVE CLASS - 1 I OBSERVED THROUGHOUT THE ENTIRE BASEMENT OFFICE AREA THE IMPROPER TERMINATION OF FLEXIBLE CORD FOR WALL MOUNTED HEAT... $1,600 $0 Jan 10, 2020
Aug 14, 2019 39007720N RESOLVE CLASS - 2 I OBSERVED IN THE CELLAR ELECTRICAL EQUIPMENT AREA THE MAIN SERVICE DISCONNECTS NOT LABELED WITH A DESIGNATION. PHOTO... $500 $0 Jan 16, 2020
Aug 14, 2019 39007717M RESOLVE CLASS - 1 OBSERVED AT THE ABOVE ADDRESS AS GAS PIPING IS IN THE STAIRWAY LOCATED AT THE CELLAR LEVEL.( AS PER FGC 404.1); FGC 4... $1,250 $0 Jan 13, 2020
Aug 14, 2019 39007718Y RESOLVE CLASS - 2 OBSERVED AT CELLAR STAIR B, APPROX. 3FT. X 3FT. OPENING IN CEILING, MISSING DRYWALL WITH BLACK MOLD ON SURROUNDING AR... $1,563 $0 Jan 16, 2020
Feb 25, 2019 35386210K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 2-25-19 AT ABOVE ADDRESS EXCESSIVE STORAGE NEXT TO THE... $625 $0 Jul 8, 2019
Feb 25, 2019 35383801Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NOTED:OBSERVED AT CELLAR LEVEL STAIR "B",A SECTION OF THE CEILI... $0 $0 Nov 27, 2019
Feb 25, 2019 35386209N RESOLVE CLASS - 1 SEC. 404.1 GAS PIPING IN PROHIBITED LOCATION-EGRESS STAIRS. OBSERVED ON 2-25-19 AT ABOVE LOCATION GAS PIPE IN BASEMEN... $1,250 $0 Jul 9, 2019
Dec 17, 2018 37013926R RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35316901X ISSUED ON 02-16-18 & TO FILE A C OF C PURSUAN... $1,250 $0 Oct 7, 2019
Nov 21, 2018 35337024X RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35316904L ISSUED ON 02/16/18 & TO FILE A C OF C PURSUAN... $2,500 $0 Mar 18, 2019
Sep 15, 2018 35389103Z RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35316904L ISSUED ON 02/06/18 & TO FILE A C OF C PURSUAN... $6,250 $0 Dec 10, 2018
Aug 7, 2018 35347085Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERVED ON 8/7/18 @ ABOVE ADDRESS IN MECHANICAL ROOM FOR APT 3G S... $625 $0 Jan 16, 2019
Aug 7, 2018 35347079M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: IN BOILER ROOMS FROM THE 4TH STORY DOWN TO 1ST STORY, THE '... $625 -$30 Jan 14, 2019
Aug 7, 2018 35347084R RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERVED ON 8/7/18 @ ABOVE ADDRESS ACTIVE LEAK ON 1 INCH PIPE IN M... $312 $0 Jan 16, 2019
Aug 4, 2018 35387318R RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35316904L ISSUED ON 02/06/18 & TO FILE A C OF C PURSUAN... $2,500 $0 Oct 22, 2018
Jun 24, 2018 35340144H RESOLVE CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35316904L ISSUED ON 02/06/18 AND TO FI... $2,500 $0 Aug 27, 2018
May 18, 2018 37010718Z RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPUR... $625 $0 Nov 5, 2018
May 14, 2018 35338451P RESOLVE CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35316904L ISSUED ON 02/16/18 AND TO FIL... $2,500 $0 Aug 27, 2018
Apr 5, 2018 35328846K RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35316902H ISSUED ON 02/16/18 AND TO FIL... $0 $0 Jul 16, 2018