Skip to content

ECB violations

39 Vernon Avenue, Brooklyn • Block 01754 • Lot 0069

14 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 2, 2006 34501936Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN. DEFECT IS: WOODEN BEAM (4" X 6") RUNNING DOWN CENTER OF CELLAR IS ROTTED OUT AT VARIOUS LOCATION... $0 $0 Jun 19, 2006
Nov 4, 2005 34502049M ACTIVE Hazardous RESIDENCE ALTERED FOR THE LEGALLY APPROVED # OF FAMILIES BLDG. DEPT RECORDS INDICATE THAT RESIDENCE IS LEGALLY APPROV... $5,300 $0 Apr 3, 2006
Nov 4, 2005 34502048K ACTIVE Hazardous WORK W/O PERMIT. ON THE 1ST FL, THE 3PC BATHROOM HAS BEEN REMOVED FROMTHE EAST SIDE OF THE FL & REPLACED W/A KITCHEN.... $800 $0 Apr 3, 2006
Nov 4, 2005 34502047Z RESOLVE Hazardous FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER TO CORRECT THE VIOLATING CONDITION OF ECB#34480608P. ERECTED NEW BAT... $0 $0 Apr 3, 2006
Aug 24, 2005 34485943P ACTIVE Non-Hazardous WORK W/O A PERMIT: WORK NOTED: RENOVATION AT BASEMENT LEVEL IN KITCHENAS FOLLOW: 1)2"X 3" WOOD STUDS BEING USED FOR C... $500 $0 Nov 29, 2005
Aug 24, 2005 34485942N RESOLVE Hazardous FAILURE TO MAINTAIN: NOTED: THE REAR YARD CONSIST OF DEBRIS, OLD STOVE, CONSTRUCTION MATERIAL ETC. STACK APPROXIMATE ... $800 $0 Nov 29, 2005
Jun 17, 2005 34480608P RESOLVE Non-Hazardous WORK WITHOUT A PERMIT.WORK NOTED:2ND AND 3RD FLOORS ERECTED NEW BATHROOM 3 PC NEW KITCHEN INTERIOR WALL PARTITIONS CR... $0 $0 Sep 12, 2005
Apr 20, 2005 34473007Y RESOLVE Non-Hazardous WORK W/O PERMIT(S);NOTE:CONVERTED THE 1ST FLR TO A "CLASS A"APT.BY INSTALLING A KITCHEN W/GAS STOVE ON SAID FLR.WATER... $0 $0 Jul 25, 2005
Apr 20, 2005 34473008X RESOLVE Hazardous RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FORM ORE THAN THE LEGALLY APPROVED # OF FAMILIES.BLDG DEPT. RECORDS IND... $0 $0 Jul 25, 2005
Apr 20, 2005 34473006M RESOLVE Hazardous FAILURE TO MAINTAIN.NOTE:THE FLR BEAMS/JOISTS LOCATED UNDER THE BATHROOM OF THE BASEMENT ARE SAGGING & ARE NOW BEING ... $0 $0 Jul 25, 2005
Dec 10, 2004 34455883P RESOLVE Non-Hazardous FAILURE TO MAINTAIN.NOTED:THE FLOOR BEAMS AT BASEMENT WHERE BATHROOM IS LOCATED IS SAGGING AND NOW SUPPORTED BY TEMPO... $800 $0 Jul 25, 2005
Jul 14, 2004 34438545H RESOLVE Hazardous FAILURE TO MAINTAIN BLDG NOTE (1) ELECTRICAL POWER CORDS RUN THROUGH STAIRWAYS ARE CREATING A RISK OF FIRE (NON SHIEL... $2,000 $0 Dec 12, 2005
Feb 11, 2004 34427526Z RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING HAZARDOUS NOTED 2ND FLOOR NO ELETRICAL POWER ELECTRICAL CORDS RUN FROM 1ST FLOOR THROUGH... $800 $0 Dec 12, 2005
Feb 11, 2004 34427527K RESOLVE Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS WHICH INDICATE A 3 WALK UP AT INSPECTION ON 2ND FLO... $800 $0 Dec 12, 2005