ECB violations

10 Pulaski Street, Brooklyn • Block 01774 • Lot 0008

22 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jan 31, 2023 39078772N ACTIVE CLASS - 2 AT TIME OF INSPECTION, OBSERVED 4 STORY BUILDING WITH C1 WALK-UP APARTMENT AT THE CORNER OF EXPOSURE # 1&2 AT THE 4-F... $625 $625 May 8, 2023
Aug 3, 2021 35508074H RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING WALL OR APPURTENANDCES.AT REAR OF BUILDING VERTICAL CRACK FROM 4TH FLOOR WINDOW... $625 $0 Dec 15, 2021
Mar 21, 2012 34947178K ACTIVE CLASS - 2 NOTED C/O #B000136838 STATES THE 1 STORY STRUCTURE AS A GARAGE FOR ORDINARY USE WHEN GARAGE DOOR WAS REMOVED AND PREM... $800 $0 Jun 18, 2012
Mar 21, 2012 34947179M ACTIVE CLASS - 2 NOTED @ REAR GARAGE WAS CONVERTED TO A SOCIAL CLUB ELECTRIC SHEROCK WALLS METALS FRAME W/ GLASS STORE FRONT AND DOOR ... $800 $0 Jun 11, 2012
Apr 13, 2011 34906041Z RESOLVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY W/AN ORDER OF COMMISSIONER. RESPONDENT FAILED TO CORRECT VIOLATING CONDITIONS CITED ... $2,400 $0 Jun 20, 2011
Mar 14, 2011 34907097M RESOLVE CLASS - 2 WORK W/O PERMIT. NOTE: AT DETACHED GARAGE,DOOR AT FRONT REMOVED & INSTALLED GLASS STORE FRONT W/GLASS DOOR STORE FRON... $0 $0 Jun 20, 2011
Mar 14, 2011 34907098Y ACTIVE CLASS - 3 OCCUPANCY CONTRARY TO C OF O #B 000136838 NOTE: DETACHED GARAGE NOW OCCUPIED AS OFFICE/REC ROOM W/2PC BATH,DECK W/WOR... $200 $0 Jun 20, 2011
Feb 25, 2011 34881446Z RESOLVE CLASS - 1 FAILURE TO COMPLY W/ AN ORDER OF COMM RESPONDENT FAILED TO CORRECT VIOLATING CONDITIONS CITED IN THE PRIOR NOV#348615... $6,000 -$6,000 Apr 11, 2011
Jul 19, 2010 34861557N ACTIVE CLASS - 1 FAILURE TO MAINTAIN BLDG EXTERIOR WALL: DEFECT NOTED: AT EXPOSURE # 4 PARAPET WALL & BRICK FACADE @ 3 & 4 STORY MISSI... $5,000 $0 Sep 13, 2010
Nov 10, 2009 32067374J ACTIVE CLASS - 2 48A/48B/32A/46B/44B/25A/25B/50A/50B/50C/50D/50E/50F/50A-FRESH AIR INTAKE FAN NOT HOT WIRED IN/50B-FIRE CHAMBER WALLS ... $2,500 $0 Jan 4, 2010
Dec 31, 2008 34742668Y ACTIVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BLDG WALL. NOTED: AT REAR 8'HIGH BRICK WALL LEANING & WITH LARGE STOP CRACKS. REMEDY: MA... $5,000 $0 Apr 15, 2010
Jun 20, 2008 34657899P ACTIVE Hazardous FAILURE TO MAINTAIN BLDG. NOTED: OBSERVED CRACKS IN THE NORTH EASTERN UPPER BRICK MASONRY WALL. MASONRY WALL AT REAR ... $2,000 $0 Oct 29, 2009
Jun 7, 2008 34652125Z ACTIVE Hazardous FAILURE TO MAINTAIN BLDG. DEFECTS AS FOLLOWS: 1)LOOSE & BULGING MASONRY PLASTER @ SOUTH EXTERIOR FACADE @ CENTER SECT... $800 $0 Oct 29, 2009
Jan 14, 2008 32055040L RESOLVE Hazardous B4A,34B,50A,B,C,D,E.50-FRESH AIR FAN TO BE HAND WIRED INTO CIRCUIT INTERLOCKED W/BURNER.50A-SAFETY CONTROLS ON 1/4 PI... $0 $0 Mar 3, 2008
Jan 8, 2008 34627949R ACTIVE Hazardous FAILURE TO MAINTAIN BLDG. NOTED: ROOF TOP COVERING IS DEFECTIVE W/ CRACKS, MISSING FLASHING (@ CORNERS) EXPOSING BLDG... $2,000 $0 Oct 29, 2009
Dec 5, 2007 32055487H RESOLVE Non-Hazardous B4A,50A,B,C,D,E.50A-HOLES IN BOILER ROOM WALLS & CEILING.50B-SEPARATE CONTROL FROM 1/4" LINE.50C-STEAM LEVAGE PAINTED... $440 $0 Apr 15, 2010
Sep 14, 2007 34584038Z ACTIVE Hazardous FAILURE TO MAINTAIN BLDG - HAZARDOUS. DEFECT NOTED: ROOF TOP COVERING IS DEFECTIVE, CRACKED, W/MISSING (FLASHING) AT ... $800 $0 Apr 15, 2010
Mar 16, 2007 32053353N ACTIVE Non-Hazardous B4A,44C,50A,50B.50A-WOOD EXPOSED IN BOILER ROOM CEILING.50B-NO FUSABLELINK DAMPER ON FRESH AIR TO BOILER ROOM. $350 $0 Apr 15, 2010
Dec 5, 2006 32050407X ACTIVE Hazardous B4B,1,51 $800 $0 Apr 15, 2010
Dec 1, 2006 32050273J ACTIVE Hazardous B4B,51,3B,40,34B,25A,B,50A,B,C,D,E,F,G,H,I,J,K.50A BOILER ROOM FUMES.50B REMOVE MANUAL RESET PRESSURE TRULL FROM LOW ... $2,500 $0 Dec 3, 2007
Jul 13, 2005 32048192P ACTIVE Non-Hazardous B4A/25A/25B/25C/50A/50B (50A)HOLES IN BOILER ROOM WALLS AND CEILING (50B)FLUE PIPE NOT PROPERLY SEALED TO CHIMNEY $2,500 $0 Apr 17, 2006
May 31, 2005 32047945X RESOLVE Non-Hazardous B4A/50A 16/50B 25B/50C 40/50D 48A 50 50) DEBRIS IN BOILER ROOM. 50A) HOLES IN BOILER ROOM. 50B) FRESH AIR FAN NOT INT... $0 $0 Jul 18, 2005