ECB violations
104 Pulaski Street, Brooklyn • Block 01775 • Lot 0023
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 2, 2025 | 39162176Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS/APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT 5TH FLOOR, MASONRY BALCONY MISSIN... | $10,000 | $10,000 | Apr 13, 2027 |
| Oct 1, 2024 | 37031603L | ACTIVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PE... | $2,500 | $0 | Mar 17, 2025 |
| Nov 30, 2020 | 35523596K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35453654Z ISSUED ON 01-19-20 AND TO FI... | $625 | $0 | Apr 14, 2021 |
| Aug 25, 2020 | 35519551P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35453654Z ISSUED ON 01/19/20 & TO FILE A CERT OF CORREC... | $1,250 | $0 | Mar 4, 2021 |
| Feb 11, 2020 | 35471818P | ACTIVE | CLASS - 2 | FAILURE TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATION OF TEMPORARY CONSTRUCTION EQUIPMENT. AT TIME ... | $625 | $0 | Jun 17, 2020 |
| Jan 30, 2020 | 35467423Z | ACTIVE | CLASS - 2 | SIDEWALK SHED/PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.AT TIME OF INSPECTION OF A 5 STY OCCUPIED BLDG ... | $2,400 | $0 | Oct 2, 2020 |
| Jan 19, 2020 | 35453654Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION IT WAS OBSERVED THAT BALCONY AT 4TH F... | $6,250 | $0 | Nov 13, 2020 |
| Jan 18, 2011 | 32069945N | RESOLVE | CLASS - 1 | B154. FAILURE TO RAISE CHIMNEY OF 108 PULASKI STREET OVER THE (PEAK) OF 104 PULASKI STREET. CHIMNEY AT 108 PULASKI HA... | $1,000 | $0 | Jun 13, 2011 |
| Sep 9, 2010 | 34858485X | RESOLVE | CLASS - 1 | BC3314.9)SUPPORTED SCAFFOLD DOESN'T MEET CODE SPECIFICATIONS.NOTED:SCAFFOLD ERECTED @ APPROX 18' IN HEIGHT IS MISSING... | $1,600 | $0 | May 2, 2011 |
| Sep 9, 2010 | 34858484Y | RESOLVE | CLASS - 1 | USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERTIFICATE.NOTED:WORKERS ON SUPPORTED SCAFFOLD DIDN'T HAVE 4HR USERS C... | $1,600 | $0 | May 2, 2011 |
| Feb 9, 2010 | 34835204Z | RESOLVE | CLASS - 2 | FAILURE TO FILE C/C W/DOB PURSUANT TO 28-204.2 FOR VIO 34813603Z. REMEDY: FILE C/C. | $0 | $0 | May 24, 2010 |
| Sep 29, 2009 | 34813603Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS NOTED ELEVATOR SHAFT OPEN AND UNPROT... | $12,000 | $0 | Jun 14, 2010 |
| Sep 29, 2009 | 34813602R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS CONSTRUCTION MATERIALS AND DEBRIS NOT PROPERLY STO... | $4,000 | $0 | Jun 14, 2010 |
| Apr 28, 2009 | 34776529J | RESOLVE | CLASS - 2 | WORK W/O A PERMIT: EXPIRED PERMIT. NOTED: PLYWOOD CONSTRUCTION EQUIPMENT FENCE INSTALLED UNDER JOB #302147479-01-EQ-F... | $0 | $0 | Jun 22, 2009 |
| Apr 25, 2008 | 34633478K | RESOLVE | Hazardous | VERTICAL SAFETY NETTING NOT PROVIDED THROUGHOUT -NOTE- AT THE TIME OF INPECTION VERTICAL SAFETY NETTING WAS NOT PROPE... | $5,000 | $0 | Jun 16, 2008 |
| Apr 25, 2008 | 34633479M | RESOLVE | Hazardous | PROVISION:27-1069 NO FDNY PERMIT FOR STORAGE AND USE OF OXYGEN AND ACETYLENE. NOTE: AT THE TIME OF THE INSPECTION OXY... | $2,500 | $0 | Jun 16, 2008 |
| Apr 25, 2008 | 34633477Z | RESOLVE | Hazardous | NO GUARD RAILS -NOTE AT THE TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE THERE WAS NO GUARD RAIL AROUND OPENING ON ... | $5,000 | $0 | Jun 16, 2008 |
| Apr 25, 2008 | 34633481L | RESOLVE | Hazardous | FAILURE TO PROVIDE HAND RAILS ON STAIRWELL AT THE TIME OF INSPECTION BUILDING UP TO 4TH FLR DECK AND THERE WERE NO HA... | $5,000 | $0 | Jun 16, 2008 |
| Apr 25, 2008 | 34633480J | RESOLVE | Hazardous | NO TOE BOARDS. -NOTE- AT THE TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE THER WAS NO TOE BOARD IN PLACE AROUND OPE... | $5,000 | $0 | Jun 16, 2008 |
| Jun 21, 2007 | 34582933X | RESOLVE | Hazardous | FAILURE TO PROVIDE ADEQUATE PROTECTION FOR SIDEWALK & WALKWAYS.UPON INSPECTION FOUND IN 6 SECTIONS LEANING IN 4 SECTI... | $5,000 | $0 | Aug 20, 2007 |