158-160 Marcus Garvey Boulevard, Brooklyn
Brooklyn • Block 01777 • Lot 0039 • Zip: 11206
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Downtown Brooklyn 31 min 13 walking, 18 riding
- Fulton Street 36 min 13 walking, 23 riding
- Union Square 37 min 13 walking, 24 riding
- Grand Central 44 min 13 walking, 31 riding
- Times Square 47 min 13 walking, 34 riding
- Penn Station 48 min 13 walking, 35 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Railroad
Ferry
Bus
Citi Bike
Places nearby
Macosa Trattoria
Neighborhood option with outdoor seating, serving classic Italian comfort foods, desserts & wine.
Sal & Cookie’s Ultra Fine Diner
No description yet
Mao Mao
No description yet
Boyfriend Co-Op
No description yet
Petisco Brazuca
No description yet
Indika House
No description yet
Greedi Vegan
Laid-back restaurant whipping up plant-based versions of classic comfort foods, plus mocktails.
Sonbul - Korean Cafe and Kitchen
Sonbul - Korean Cafe and Kitchen is a cozy and inviting restaurant in Brooklyn, NY, serving up authentic Korean dishe...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2024
-
HPD violation Nov 27, 2024
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
DOB violation Sep 23, 2024
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Sep 23, 2024
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 INTERNAL HGH PRESSURE INSPECTION
2023
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
-
HPD violation Mar 22, 2023
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2022
-
HPD violation Feb 24, 2022
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2021
-
HPD violation Apr 8, 2021
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2019
-
HPD violation Oct 9, 2019
Class B
§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP...
2016
-
HPD violation Nov 4, 2016
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
Alteration Type II
SPLIT AC UNIT FOR "PAY-O-MATIC" RETAIL STORE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2006
-
Hazardous
50. HURST V-T BOILER, 10HP, NB 9444, GAS 2001 50 STEAM PRESSURE GAUGE HAS A DIAL RANGE OF 0-160 PSI. MAWP & SAFETY VA...
2005
-
Non-Hazardous
6A) HURST V.T. BOILER, 10HP, NB 9444, GAS, 2002 6A) LEAKING SAFETY VALVE ON BOILER. REPLACE.
2003
-
Alteration Type I
TO OBTAIN NEW C OF O FOR EXISITNG 4 STOR IES COMMERCIAL AND RESIDENTIAL UILDING WORK INCLUDES INSTALLATION OF NE W ST...
-
Alteration Type II
New sprinkler heads installation. No change of egress, use, and occupancy.
-
Alteration Type II
REPLACEMENT OF D.C.M. IN EXIST'G DRY CLEANERS AND EXIST'G OIL BOILER IN CELLAR TO BE REPLACED WITH GAS BOILER ( BOILE...
-
Alteration Type II
Renovation of existing building. Work includes roof replacement, new floor covering , ceiling and partition removal. ...
2002
1993
-
Hazardous
3A,FLUE PIPE SECTION DISLOCATED FROM JOINTS, NOT SECURED PROPERLY AND SEALED GAS TIGHT.
1991
-
Non-Hazardous
17(A),17(B),32,NIPPLE IN WATER COLUMN CORREDED TO REPLACE BY NEW ONE. (
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records