Issued Class Status Violation Apartment Correct by
Jun 19, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOODEN FLOORS ALL ROOMS, 2ND STORY APARTMENT. Jul 24, 2008
Jun 19, 2008 B NOT COMPLIED WITH § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING -CAST IRON HANDRAIL AT CAST OF FRONT ENTRANCE STOOP TO 1ST STY APT. Jul 24, 2008
Jun 19, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING WASTE PIPE TO KITCHEN SINK, 2ND STORY APARTMENT. Jul 24, 2008
Jun 19, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WALL OUTLETS ALL ROOMS, 2ND STORY APARTMENT. Jul 24, 2008
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB BASEMENT IN THE BATHROOM LOCATED AT APT 1 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING AND WALLS BASE... 1 Aug 19, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR BASEMENT IN THE KITCH... 1 Jul 21, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PANEL WALLS BASEMENT LEVEL ... 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING BASEMENT IN TH... 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PANEL WALLS IN THE 1st ROOM... 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING AND WALLS IN T... 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING AND WALLS IN T... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM ... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING AND WALLS IN T... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING AND WALLS IN T... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK WALLS AND CEILING IN T... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATE... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSE WIRE AT CEILING THROUGHOUT , CELLAR Aug 19, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2010,2011,2012 ADMIN. CODE: CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE THE ... Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF WATER LEAK AT MAIN SEWER LINE AT NORTH WEST , CELLAR Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT. THE BROKEN MAIN BEAM AND SIX BROKEN JOI... Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTERS AT HAND RAIL ON STAIRS THROUGHOUT AT PUBLIC HALL Jul 21, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER ALL WALLS AND CEILINGS T... Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR JOINTS AT CHIMN... Aug 19, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF GLASS AT SKYLIGHT, ROOF Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT. WOOD STRINGERS ,TREADS AND RISERS , BAL... Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT. STRINGERS , TREADS AND RISERS AT STAIRS... Jul 21, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING AND WALLS... BSM Aug 19, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATE... BSM Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE 2n... BSM Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILI... Jul 21, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 2nd STORY Jul 21, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR FIRE RETARDANT MA... Aug 19, 2006
Jul 3, 2006 A FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS I... 1 Oct 18, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILINGS AND WALL... BSMT Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILINGS AND WALL... 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR THROUGHOUT IN THE ENT... 2 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILINGS AND WALL... 2 Aug 19, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROVIDE TEMPORARY SEAL-UP OFAPT/ ROOMS OF 1st AND 2nd STORIES AT PUBLIC HALL Jul 21, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR THROUGHOUT IN THE ENT... BSMT Aug 19, 2006
Jul 3, 2006 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR BASEMENT IN THE B... 1 Jul 21, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK WALLS AND CEILING BASE... 1 Aug 19, 2006
Jul 3, 2006 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC TILES AT EAST,WEST, AND SOUTH WALLS BASEMENT IN THE BATHR... 1 Aug 19, 2006
Jun 26, 2003 I NOT COMPLIED WITH § 27-2142 ADM CODE - THE PREMISES OR APTS. HAVE BEEN VACATED BY THE DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDE... Oct 4, 2003