Issued Violation Status Severity Description Penalty Balance due Hearing
Sep 27, 2024 37029206P ACTIVE CLASS - 2 FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000074516Y0001 IN ACCORDANCE WITH... $3,125 $3,125 Jan 8, 2025
May 21, 2019 35398948P RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35362980K ISSUED ON 2-13-19 AND TO FILE... $0 $0 Sep 9, 2019
Apr 24, 2019 35416322J RESOLVE CLASS - 3 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.OBSERVED ON 1ST FLOOR IN APARTMEN... $0 $0 Aug 5, 2019
Apr 24, 2019 35416321H RESOLVE CLASS - 3 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCS.AND/OR APPROVED AMENDMENTS.OBSERVED ON 3RD FL.IN APARTMENT 3R IN ... $0 $0 Aug 5, 2019
Feb 13, 2019 35362980K RESOLVE CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP OWORK ORDER. REF TO DOB RECORDS SWO (PARTIAL) ISSUED ON 09/10/2018 ... $0 $0 Aug 21, 2019
Feb 13, 2019 35362981M RESOLVE CLASS - 1 28-104.8.4 TENANT PROTECTION PLAN NOT FILED OR INADEQUATE. REF TO DOBRECORDS NO TENANT PROTECTION PLAN ISSUED FOR APT... $625 $0 May 20, 2019
Sep 10, 2018 35362289X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED IN APT #2R IN LIVINGROOM WALL AND BATHROOM WALL (2) B... $310 $0 Dec 3, 2018
Sep 10, 2018 35362288Y RESOLVE CLASS - 1 WORK WITHOUT A PERMIT. REF TO DOB RECORDS FILE #321705151 ISSUED 02/06/18 TYPE (ALT 2) APT 1R & 3L. HOWEVER, OBSERVED... $1,600 $0 Dec 3, 2018
Aug 29, 2018 35307080N RESOLVE CLASS - 2 BC27-2009.2/FAILURE TO DISTRIBUTE OR POST SAFE CONSTRUCTION BILL OF RIGHTS.NOTED:FAILURE TO POST SAFE CONSTUCTION BIL... $0 $0 Dec 3, 2018
Aug 29, 2018 35346151N RESOLVE CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEMS.FROM THE MAIN ELECTRICAL SERVICE THERE IS NO GROUNDING ELECTRODE TO THE WATER MA... $4,800 $0 Nov 19, 2018
Aug 29, 2018 35307079X RESOLVE CLASS - 2 BC28-104.8.4.3/FAILURE TO DISTRIBUTE OR POST NOTICE OF TENANT PROTECTION PLAN.NOTED:FAILURE TO POST TENANT PROTECTION... $0 $0 Dec 3, 2018
Aug 29, 2018 35346152P RESOLVE CLASS - 2 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS MATERIALS,DEVICES, APPLIANCES OR WIRING INUSE.THROUGHOUT ... $800 $0 Nov 19, 2018
Aug 29, 2018 35316468Y RESOLVE CLASS - 2 WORK W/O A PERMIT. I OBSERVED IN THE CELLAR AREA, THE ENTIRE CELLAR UNDERGROUND STORM PIPING AND SANITARY PIPING BEIN... $1,250 $0 Nov 19, 2018
Aug 29, 2018 35307078Y RESOLVE CLASS - 1 BC3303.10/TENANT PROTECTION PLAN NOT BEING COMPLIED WITH.NOTED;AT TIMEOF INSPECTION EXCESSIVE DUST ON ALL FLOORS,INAD... $2,500 $0 Dec 7, 2018
Aug 29, 2018 35307077M RESOLVE CLASS - 1 FAILUR TO MANTAIN BUILDING IN CODE COMPLIANT MANNER"NO FIRE STOPPING"OTED:APT#1R MISSING FIRE RATING AT CEILINGS AND ... $2,500 $0 Dec 7, 2018
Jul 12, 2018 35333633N RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. NOTE: OBSERVED DURING INSPECITON WO... $620 $0 Sep 17, 2018
Jun 21, 2004 34440622P ACTIVE Hazardous 1)FAILURE TO MAINTAIN NOTED:IMPROPERLY CONSTRUCTED WOOD STAIRCASE (EXTERIOR) AT 1ST STORY FRONT TO CELLAR ROTTED,FALL... $800 $0 Mar 28, 2005