ECB violations
1209 Fulton Street, Brooklyn • Block 01842 • Lot 0066
32 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 19, 2026 | 39549284M | RESOLVE | CLASS - 1 | B.C 3301.13.5 OBSERVED AN ACTIVE SITE COMPETENT PERSON ON SITE. UPON CHECKING CONSTRUCTION SUPER LOG BOOKS, SUPER FAI... | $5,000 | $5,000 | Feb 9, 2027 |
| Dec 2, 2025 | 39547531L | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED WORK AT THE BULKHEAD COMPLETED WHILE UNDER STOP WORK ORDER. GC FAIL TO COMPLY WITH THE... | $10,000 | $10,000 | Dec 8, 2026 |
| Nov 5, 2025 | 39546677J | RESOLVE | CLASS - 1 | ELEVATOR NOT AT READINESS AT THE TIME OF INSPECTION ON A ACTIVE JOB SITE OF A 9 STORY BUILDING CURRENTLY AT ROOF LEVE... | $5,000 | $5,000 | Sep 15, 2026 |
| Sep 25, 2025 | 39545355M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTING OBSERVED ACCESS TO THE BULKHEAD,OBSERVED APPROXIMATELY 16 INCHES OF MASONRY BRICK INSTALLED AT ... | $5,000 | $5,000 | Aug 17, 2026 |
| Aug 24, 2025 | 39544033P | RESOLVE | CLASS - 1 | I OBSERVED AN ACTIVE WORK SITE. WORKERS ON ALL FLOORS. NO ACTIVE AFTER HOUR VARIANCE PERMIT ACTIVE. VIOLATING SECTION... | $2,500 | $2,500 | Jan 25, 2027 |
| Aug 24, 2025 | 39544036K | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION I OBSERVED AN ACTIVE SITE WITHOUT AN AHV PERMIT TO WORK ON 08-24-25 PILES OF COMBUSTIBLE MATERI... | $2,500 | $2,500 | Jul 27, 2026 |
| Aug 24, 2025 | 39544037M | RESOLVE | CLASS - 2 | I OBSERVED AN ACTIVE SITE WITHOUT AN AHV PERMIT TO WORK ON 08-24-25 GENERATOR ON SIDEWALK PARTIALLY ENCLOSED WITH JER... | $2,500 | $2,500 | Jul 27, 2026 |
| Aug 24, 2025 | 39544059N | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION,I OBSERVED AN ACTIVE SITE WITH APPROXIMATELY 24 WORKERS. THERE WAS NO ACTIVE AFTER HOURS VARIAN... | $2,500 | $2,500 | Jan 25, 2027 |
| Aug 24, 2025 | 39544035Z | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, I ASKED FOR ALL LOGS. COMPETENT PERSON WAS NOT ABLE TO SHOW ME CONCRETE STRAP SAFETY DAILY LOG... | $1,250 | $1,250 | Jan 25, 2027 |
| Jul 2, 2025 | 39541929Y | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, I OBSERVED SOLDIER PILES ,WHALERS AND BRACE NOT PROVIDED AND MAINTAIN AS PER APPROVED DRAW... | $0 | $0 | Jun 25, 2026 |
| Jul 2, 2025 | 39541930L | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, I OBSERVED EXISTING FOUNDATION AT EXPOSURE#1 IN PROGRESS OF DEMOLITION AND REMOVAL UPON RE... | $0 | $0 | Jun 25, 2026 |
| Jul 2, 2025 | 39541931N | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION CONSTRUCTION OPERATION IN PROGRESS, I OBSERVED TRUCK PARKED OBSTRUCTING SIDEWALK SHARED BY P... | $0 | $0 | Jun 25, 2026 |
| Jul 2, 2025 | 39541932P | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION ACTIVE EXCAVATED JOBSITE I OBSERVED INSIDE THE SITE, LOCATED AT EXPOSURE#2 A HOLE APPROXIMA... | $0 | $0 | Jun 25, 2026 |
| Dec 21, 2023 | 35675492Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE MEANS AND METHOD BY P.E FOR CONCRETE REPAIR. AS NOTED: AT TIME OF MY INSPECTION AT AN ACTIVE JOBSI... | $0 | $0 | Feb 28, 2024 |
| Jan 30, 2023 | 39512250P | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ERECTED WITH PIPE SCAFFOLD ERECTED ON TOP BOTH WITH VALID PERMIT. I OB... | $0 | $0 | Feb 4, 2025 |
| Jan 30, 2023 | 39512249H | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OF A 4 STOREY BUILDING I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1 WITH INOPERABLE LIGHT ... | $0 | $0 | Feb 4, 2025 |
| Jul 13, 2022 | 39503465H | RESOLVE | CLASS - 1 | SUPPORTED SCAFFOLD NOT TO CODES.OBSERVE SUPPORTED SCAFFOLD IN PLACE TOP OF SHED UP TO ROOF LEVEL JOB#B00318701-I1-SF ... | $1,250 | $0 | Feb 27, 2023 |
| Jul 13, 2022 | 39503466J | RESOLVE | CLASS - 2 | SIDEWALK SHED BC 3307.6.OBSERVE SIDEWALK SHED JOB#B00317825 IN PLACE FOR 4 STORY BUILDING WITH SUPPORTED SCAFFOLD ON ... | $2,400 | $0 | Feb 27, 2023 |
| Jul 13, 2022 | 39503476N | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN SIDEWALK SHED.TO COMPLAINT OBSERVE SIDEWALK SHED IN PLACE WITH SCAFFOLD ON TOP FOR 4 STORY BUILDING ... | $0 | $0 | Nov 15, 2022 |
| Jul 13, 2022 | 39503477P | RESOLVE | CLASS - 2 | OBSERVE SIDEWALK SHED IN PLACE MISSING PARAPET PANEL AS REQUIRED TO CODES BC3301.9.2-3301.9.2.1.1,3301.9.2.2-3301.9.2... | $0 | $0 | Nov 15, 2022 |
| May 3, 2022 | 39501112N | RESOLVE | CLASS - 1 | AT 4 STORIES BUILDING NO WORK, OBSERVED SUPPORTED SCAFFOLD AT EXPOSURE 1 WITH LOSE NETTING UNSAFE NOT FULLY ENCLOSED,... | $0 | $0 | Jan 8, 2026 |
| May 3, 2022 | 39501113P | RESOLVE | CLASS - 2 | AT 4 STORIES BUILDING NO WORK, OBSERVED SIDEWALK SHED AT EXPO 1, SHARP EDGES WERE EXISTING AROUND SEATING AREA UNDER ... | $1,562 | $0 | Aug 17, 2026 |
| Apr 6, 2022 | 39500342Y | RESOLVE | CLASS - 2 | DEBRIS NETTING. OBSERVED SUPPORTED PIPE SCAFFOLD INSTALLED AT EXP#1 NOT AS PER CODE, OBSERVED MISSING, LOOSE AND DAMA... | $1,250 | $0 | Aug 10, 2022 |
| Nov 18, 2021 | 35632562P | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS-SIDEWALK SHED NOT MAINTAIN.NOTE:AT THE TIME OF MY INSPECTION ... | $5,000 | $0 | Mar 30, 2022 |
| Nov 18, 2021 | 35632563R | RESOLVE | CLASS - 1 | BC33141-FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFOLD AS REQUIRED.NOTE:AT THE TIME OF MY INSPECTION OBSERVED SUPPORTED ... | $6,250 | -$6,250 | Mar 30, 2022 |
| Nov 10, 2021 | 35504776Y | RESOLVE | CLASS - 2 | BC3301.9.2 SWS PARAPET PANEL NOTE:ATOI,I OBSERVED SWS ERECTED@EXP1.I ALSO OBSERVED THAT THERE WERE NO SWS PARAPET PAN... | $3,125 | $0 | Mar 23, 2022 |
| Nov 10, 2021 | 35632549K | RESOLVE | CLASS - 2 | PEDESTRIANS PROTECTION DOESNT MEET SPECS3307.6.4.8 NOTE:ATOI,I OBSERVED SWS ERECTED@EXP1.I ALSO OBSERVED THAT UNDERSI... | $5,000 | $0 | Mar 23, 2022 |
| Jul 30, 2021 | 35585429R | RESOLVE | CLASS - 2 | PROJECT INFORMATION PANEL ON THE SIDEWALK SHED PARAPET PANEL IS NOT PROVIDED. NOTE: AT THE TIME OF MY INSPECTION OF A... | $3,125 | $0 | Dec 8, 2021 |
| Jul 30, 2021 | 35585427N | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPEFICIATIONS. NOTE: AT THE TIME OF MY INSPECTION OF AN UNOCCUPIED 4 STY BLD... | $5,000 | $0 | Dec 8, 2021 |
| Jul 30, 2021 | 35585428P | RESOLVE | CLASS - 2 | SEC. BC3314.4.8 SCAFFOLDS ALL COMPONENTS OF & ATTACHMENTS TO THE SUPPORTED SCAFFOLDS SHALL BE MAINTAINED IN GOOD COND... | $3,125 | $0 | Dec 8, 2021 |
| Mar 9, 2021 | 35551103L | RESOLVE | CLASS - 2 | SEC. 3307.6.4.8 SIDEAWLK SHED LIGHTING. NOTE: AT TIME OF MY INSPECTIONOF A 4 STY BLDG I OBSERVED AT 5:50AM THAT THE L... | $5,000 | $0 | Jul 21, 2021 |
| Jul 9, 2020 | 35481409N | RESOLVE | CLASS - 2 | SIDEWALK SHED/PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT THE TIME OF INSPECTION I OBSERVED SIDEWALK ... | $5,000 | $0 | Nov 18, 2020 |