Maintenance code violations
8 Herkimer Court, Brooklyn • Block 01868 • Lot 0025
17 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2010,2011,2012 ADMIN. CODE: CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING TH... | — | Feb 18, 2009 |
| Feb 12, 2009 | B | NOT COMPLIED WITH | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE BALUSTRADE 1ST-2ND STORY PUBLIC HALL. | — | Mar 19, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES 2ND STORY APT 2, BATHROOM AND KITC... | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES 2ND STORY APT 2, BATHROOM AND KIT... | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING OVER ENTIRE APT. 2ND STORY APT #2. | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASH BASIN AND BATHTUB BATHROOM, 2ND S... | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING BAT... | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2010,2011,2012 ADMIN. CODE: CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING TH... | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT BOILER, CELLAR REAR. | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM, 1ST STORY APT -1 | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM, 2ND STORY APT #2. | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM., 2ND STORY APT #2. | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF NO ELECTRIC SERVICE PROVIDED AT LIGHT FIXTURE. ALL STOR... | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF NO ELECTRIC SERVICE PROVIDED AT 2ND STORY APT #2. | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS TOP SASH IN WINDOW BATHROOM 2ND. STY. APT. 2. | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2ND STY APT #2 | — | Feb 18, 2009 |
| Feb 12, 2009 | C | NOV SENT OUT | SECTION 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES KITCHEN GAS RANGE 2ND STY APT. #2 | — | Feb 18, 2009 |