ECB violations
95 Waverly Avenue, Brooklyn • Block 01889 • Lot 0022
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 17, 2021 | 35590093Z | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARDRAILS,HANDRAILS.AT TIME OF ... | $2,500 | $0 | Apr 27, 2022 |
| Dec 17, 2021 | 35590094K | RESOLVE | CLASS - 2 | BC3301.6.1 TEMPORARY SHORING IN PLACE WITH NO DESIGN DRAWING.AT TIME OF INSPECTION OBSERVED TEMPORARY SHORING USED AS... | $620 | $0 | Apr 27, 2022 |
| Oct 8, 2020 | 35499507M | RESOLVE | CLASS - 2 | SEC. 3307.6.4.8 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS: NOTE: AT TIME OF MY INSPECTION OF A 3 STY BL... | $5,000 | $0 | Mar 11, 2021 |
| Oct 8, 2020 | 35499508Y | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE. EXP PERMIT-SIDEWALK SHED. NOTE: AT TIME OF MY INSPECTION OF A 3 STY BLDG I ... | $3,125 | $0 | Mar 11, 2021 |
| Oct 8, 2020 | 35499509X | RESOLVE | CLASS - 2 | PROJECT INFORMATION/SIDEWALK SHED PARAPET PANEL NOT PROVIDED. NOTE:AT TIME OF MY INSPECTION OF A 3 STORY BUILDING,I O... | $1,250 | $0 | Feb 24, 2021 |
| Jul 13, 2020 | 35481414H | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT THE TIME OF INSPECTION I OBSERVED SIDEWALK SHED AT EXP#1 ... | $2,400 | $0 | Nov 25, 2020 |
| Jul 13, 2020 | 35481415J | RESOLVE | CLASS - 2 | SIDEWALK SHED/PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. AT THE TIME OF INSPECTION,I OBSERVED SIDEWALK S... | $2,400 | $0 | Nov 25, 2020 |
| Jul 11, 2016 | 35195547Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS AND APPURTENANCES. NOTE: AT EXP#1 FROM GRADE LEVEL TO PARAPET, VERTICAL AND HORIZONTAL... | $0 | $0 | Sep 12, 2016 |
| Jun 25, 2016 | 35158588H | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE:OBSERVED SIDEWALK SHED ERECTED AT EXP#1.SIDEWALK SHED LI... | $5,000 | $0 | Aug 15, 2016 |
| Apr 17, 2016 | 35177783R | RESOLVE | CLASS - 1 | RE-ISSUE: ECB#35154734Z. FAILURE TO MAINTAIN BDG WALL(S) OR APPURTENANCES. NOTED: @ EXP#1 FROM GRADE TO PARAPET VERTI... | $0 | $0 | Jul 18, 2016 |
| Nov 8, 2015 | 35154734Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES.NOTE: AT EXP1 FROM GRADE TO PARAPET ARE VERTICAL AND HORIZONTAL CRACKS... | $0 | $0 | Dec 28, 2015 |
| Apr 26, 2010 | 34832543J | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTE : NO LIGHTS ON SIDEWALK SHED AT TIME OF INSP. THE UNDERSIDE OF ... | $10,000 | $0 | Oct 26, 2011 |
| Mar 27, 2010 | 34803949R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE INFORMATION OF SIDEWALK SHED SIGN NOTED: THREE AVE EXP DATE ON SIGN 09.17.2009 INSTEAD OF 3-16-10.... | $4,000 | $0 | Dec 13, 2010 |
| May 1, 2009 | 34765035X | RESOLVE | CLASS - 2 | FOLLOWING THE RECEIPT OF A PERMIT TO ERECT A SIDEWALK SHED, THE PERMITHOLDER SHALL POST A READILY VISIBLE SIGN ON THE... | $0 | $0 | Jun 22, 2009 |
| Nov 14, 2008 | 34702216R | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONSNOTE LIGHTING FOR UNDE RSIDE OF SIDEWALK SHED NOT OPERATING AT INSP TI... | $10,000 | $0 | Jan 5, 2009 |