ECB violations
166 Washington Avenue • Block 01889 • Lot 0088
7 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 14, 2023 | 35633033Y | RESOLVE | CLASS - 1 | MISCELLANEOUS VIOLATIONS. DEFICIENT UNDERPINNING/SUPPORT OF EXCAVATIONDRAWINGS. THE RESPONDENT FAILED TO MEET THE REQ... | $2,500 | $0 | Dec 13, 2024 |
| Jun 28, 2023 | 39518385J | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED MISSING SHORING AND/OR SOE AROUND EXCAVATED AREA AT EXPOSURE 3 AND 4. NO WORK ALL... | $0 | $0 | Sep 6, 2023 |
| Jun 28, 2023 | 39518386L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED REMAINING CONCRETE RESIDUE ON THE GROUND AT EXPOSURE 3. G.C FAILED TO COMPLY WITH... | $0 | $0 | Sep 6, 2023 |
| May 15, 2023 | 39516653H | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION ALT BUILDING I OBSERVED MECHANICAL EXCAVATOR KOMATSU NME3 REMOVING EXSISTING FOUNDATION CHE... | $0 | $0 | Jul 26, 2023 |
| May 15, 2023 | 39516654J | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION ALT I OBSERVED SOE WORK REAR WORKER STAND FRONT OF THE MACHINE BUCKET AND POWER CABLE ABOVE... | $0 | $0 | Jul 26, 2023 |
| May 15, 2023 | 39516651Y | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION ALT BUILDING I OBSERVED RAMP RUNNING UNDER TEMPORARY SHORING NO APPROVED DRAWING OR STRUCTU... | $0 | $0 | Jul 26, 2023 |
| May 15, 2023 | 39516658R | RESOLVE | CLASS - 2 | OBSERVED FLOOR OPENING 1ST FL MORE THAN 25% WITH TEMP SHORING SUP NO APPROVED DRAWING FOR WORK THAT DONE, NO PE STRUC... | $2,500 | $0 | Jul 26, 2023 |