ECB violations
75-77 Clifton Place, Brooklyn • Block 01948 • Lot 0042
40 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 19, 2025 | 39148388J | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE PERMIT# B00865540-I1-PL EXPIRES ON 1/23/2026 ARE NOT POSTED AT THE BUILDING FRO... | $300 | $0 | Jul 23, 2025 |
| Jun 12, 2024 | 39116694L | RESOLVE | CLASS - 1 | UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER AS STATED IN ECB 35666938J ISSUED ON 07/03/2023 AND FI... | $2,500 | $2,500 | Apr 21, 2025 |
| Aug 25, 2023 | 35677231J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED: AT TIME OF INSPECTION AT ABOVE PREMISES OBS... | $1,250 | $0 | Aug 19, 2024 |
| Aug 15, 2023 | 35656186R | RESOLVE | CLASS - 1 | BC 3303.10.1 28-120 FAILURE TO COMPLY WITH TENANT PROTECTION REQUIREMENTS. AT TIME OF INSPECTION, OBSERVED CONSTRUCTI... | $6,250 | $6,250 | Jun 3, 2024 |
| Jul 28, 2023 | 39091265P | RESOLVE | CLASS - 2 | I OBSERVED IN BUILDING SPRINKLER SYSTEM LEAKED AND SEVERAL SPRINKLER HEADS WERE REPLACED ON MAIN SPRINKLER LINE AND N... | $1,250 | $0 | Oct 4, 2023 |
| Jul 3, 2023 | 35666949P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING INADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT. NOTE: AT TIME ON INSPECTION OBSERVED ST... | $2,500 | $0 | Sep 6, 2023 |
| Jul 3, 2023 | 35666941K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSON AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION. NOTE: AT TIME OF INSPECTION OBSERVED... | $10,000 | $0 | Jul 1, 2024 |
| Jul 3, 2023 | 35666945H | RESOLVE | CLASS - 1 | BC 3303.10 TENANT PROTECTION PLAN NOT BEING COMPLIED WITH. NOTE: AT TIME OF INSPECTION, OBSERVED WORK UNDER THE AFORE... | $2,500 | $0 | Sep 6, 2023 |
| Jul 3, 2023 | 35666942M | RESOLVE | CLASS - 1 | 28-201.1 TENANT PROTECTION PLANS INADEQUATE FOR SCOPE OF WORK. NOTE:AT TIME OF INSPECTION, OBSERVED WORK UNDER THE AF... | $2,500 | $0 | Jul 1, 2024 |
| Jul 3, 2023 | 35666943Y | RESOLVE | CLASS - 1 | B 3303.10 TENANT PROTECTION PLAN NOT BEING COMPLIED WITH. NOTE AT TIME OF INSPECTION, OBSERVED WORK UNDER THE AFOREME... | $2,500 | $0 | Jul 1, 2024 |
| Jul 3, 2023 | 35666939L | RESOLVE | CLASS - 1 | CONSTRUCTION WORK WITHOUT PERMIT. NOTE: AT TIME OF INSPECTION OBSERVED NEWLY INSTALLED DROP CEILING THAT WAS INSTALLE... | $2,500 | $0 | Sep 6, 2023 |
| Jul 3, 2023 | 35667000N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING FOR SECTION REQUIREMENTS. NOTE: AT TIME OF INSPECTION, OBSERVED WORK UNDER ... | $0 | $0 | Jul 1, 2024 |
| Jul 3, 2023 | 35666938J | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT. NOTE: AT TIME OF INSPECTION OBSERVED ELECTRICAL WORK IN APT 4 PHE BEING PERFORMED, ... | $1,600 | $0 | Sep 6, 2023 |
| Jul 3, 2023 | 35666944X | RESOLVE | CLASS - 1 | 28-201.1 TENANT PROTECTION PLAN INADEQUATE FOR SCOPE OF WORK. NOTE: ATTIME OF INSPECTION, WORK UNDER AFOREMENTIONED J... | $2,500 | $0 | Sep 6, 2023 |
| Jun 12, 2023 | 39088294R | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED AT STAIRCASE B EXPOSED WOOD ON CEILING. ALSO WOOD EXPOSED AT STAIRCASE A AND CORRIDORS... | $1,250 | $0 | Aug 16, 2023 |
| Sep 17, 2022 | 39070273M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED BUILT ROOF DECKING ILLEGALLY ON ROOFTOP WHICH IS CONTRARY TO EXISTING C OF O # 3007295... | $2,500 | $0 | Aug 7, 2023 |
| Sep 17, 2022 | 39070274Y | RESOLVE | CLASS - 1 | OBSERVED CONSTRUCTION DEBRIS FELL TO APT # 6C FROM ROOFTOP CONSTRUCTION. ROOFTOP AND FACADE ACTIVE PERMIT # B00724983... | $10,000 | $0 | Feb 15, 2023 |
| Aug 24, 2022 | 39068783J | RESOLVE | CLASS - 1 | DEFECTIVE DOOR LOCK MONITORING ON THE CONTROLLER. AFTER DISENGAGING THE HALL DOOR IN THE CLOSE POSITION. THE CAR DOOR... | $1,250 | $1,250 | Jan 25, 2023 |
| Mar 24, 2022 | 39058850L | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SELF-CLOSING DOOR: AT 2ND FLOOR STAIRWELL A - DOOR WITH SELF CLOSING HINGES NOT PROPERLY CHARGED /... | $625 | $0 | Jul 27, 2022 |
| Jun 2, 2021 | 35555014H | ACTIVE | CLASS - 2 | SEC. 28-116.4 FAILURE TO COMPLY W/DOB'S REQUIREMENT FOR PERMIT SIGN OFF;NOTED: RESPONDENT OBTAINED PERMIT#'S 32083465... | $1,250 | $0 | Oct 13, 2021 |
| Jun 2, 2021 | 35555011M | ACTIVE | CLASS - 2 | SEC. 28-116.4 FAILURE TO COMPLY W/DEPT OF BLDG'S REQUIREMENT FOR PERMIT SIGN OFF; NOTED: RESPONDENT OBTAINED PERMIT#'... | $1,250 | $0 | Oct 13, 2021 |
| Jun 2, 2021 | 35555012Y | ACTIVE | CLASS - 2 | SEC. 28-116.4 FAILURE TO COMPLY W/DOB'S REQUIREMENT FOR SIGN OFF; NOTED: RESPONDENT OBTAINED PERMIT#'S 340283482 & 32... | $1,250 | $0 | Oct 13, 2021 |
| Jun 2, 2021 | 35555013X | ACTIVE | CLASS - 2 | SEC. 28-116.4 FAILURE TO COMPLY W/DOB'S REQUIREMENT FOR SIGN OFF; NOTED: RESPONDENT OBTAINED PERMIT#'S 321043438 & 32... | $1,250 | $0 | Oct 13, 2021 |
| Jul 31, 2020 | 39026194X | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL... | $1,250 | $0 | Dec 2, 2020 |
| Nov 19, 2019 | 38271504P | RESOLVE | CLASS - 2 | 59-BB-15: BRAKE TAG EXPIRED. 77-B-01: PROVIDE PLATFORM AND LADDER AS PER CODE (2.2.8). (PROVIDE PLATFORM IF THE SPRIN... | $625 | $0 | Jul 16, 2020 |
| Apr 14, 2017 | 38253905R | RESOLVE | CLASS - 2 | 12Q03,16H11,42R11,52H10,56J01,59U15,68B07,72B07,77B07,80B07. 12Q03- LIGHTS NOT GUARDED; 16H11-1ST FLR HANDLER ROLLER ... | $2,500 | $0 | Jun 5, 2017 |
| Feb 13, 2017 | 38253721M | RESOLVE | CLASS - 2 | 80B14,40M7/80B14-HOIST CABLES NEED TO BE SHORTEN;40M7-LABEL ROOF DOOR TO SHOW WHERE ELEVATOR MACHINE ROOM IS LOCATED. | $500 | $0 | Jun 26, 2017 |
| Feb 3, 2017 | 38253129N | RESOLVE | CLASS - 1 | 97X17 THE ONLY ELEVATOR IN BLDG ON SECTION OF BLDGS OUT OF SERVICE UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF S... | $1,000 | $0 | Mar 20, 2017 |
| Sep 21, 2016 | 38246251L | RESOLVE | CLASS - 1 | *05L10,12Q03,16B11,08V01,14J01,17M11,10H11,29Q03,68M07,26T15,60Q03,70P07,100#07. *CLASS 1 ITEM; 05L-DISABLED ZONE LOC... | $5,000 | $0 | Feb 6, 2017 |
| Aug 19, 2016 | 38244872P | RESOLVE | CLASS - 1 | 05A10 ZONE RESTRICTOR ALTERED/INOPERATIVE. | $1,000 | $0 | Dec 28, 2016 |
| Aug 19, 2016 | 38244861J | RESOLVE | CLASS - 1 | CLASS1-05A10,12Q03,98M07,60Q03,05B01. CLASS 1 FOR FIRST ITEM; 05A-ELEVATOR COMPANY ALTERED CAB DOOR ZONE RESTRICTOR/I... | $1,030 | $0 | May 3, 2017 |
| Sep 21, 2015 | 35137584H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY IN THAT THERE IS A LARGE ACCUMULATION OF RUBBISH & DEBRIS BEING STORE... | $1,000 | $0 | Nov 9, 2015 |
| Dec 1, 2014 | 35112661L | RESOLVE | CLASS - 1 | WORK W/O A PERMIT.NOTED: APTS 5C,2B, 4E. NEW ELECTRICAL LINES,SWITCHESLIGTING OUTLETS,INSTALLED AND BEING INSTALLED. ... | $1,630 | $0 | Jun 22, 2015 |
| Oct 18, 2010 | 38212868X | RESOLVE | CLASS - 3 | 12Q03,67X10,70O02,100M07,41M07,69M70,68B07,81M07. 12Q- CAR LIGHTING CEILING PANELS MISSING. 67X- CAR EMERGENCY PHONE ... | $0 | $0 | Apr 6, 2011 |
| Sep 20, 2010 | 38212419K | RESOLVE | CLASS - 3 | 70/O/02,12/O/06,67/X/07,14/M/07,99/M/05/12D-LIGHTS IN CAR TO BE COVERED/99M-1 YR GOV TAG MISSING | $0 | $0 | Apr 6, 2011 |
| Jan 24, 2007 | 38163641N | RESOLVE | Non-Hazardous | 83M05.83M-FILE FOR REMOVAL OF DEVICE. | $2,500 | $0 | Mar 19, 2007 |
| Jan 2, 2002 | 34312579M | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED W/O A VALID CERTIFICATE OF OCCUAPCNY NOTE ; TEMPORARY C OF O # 300729507 INDICATE OCCUPANCY... | $350 | $0 | Apr 21, 2003 |
| Dec 9, 2000 | 34265437H | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. ALTERATION NUMBER:300729567 REMEDY:OBTAIN A VALID... | $350 | $0 | Jan 29, 2001 |
| Nov 30, 2000 | 38109623M | RESOLVE | Non-Hazardous | 73## 73-#-#-DEVICE 3F2080 WAS REMOVED, FILE FOR REMOVAL. | $1,000 | $0 | Jan 22, 2001 |
| Dec 10, 1998 | 34186855P | RESOLVE | Hazardous | FAILURE TO PROVIDE ADEQUATE PROTECTION FOR SIDEWALKS & WALKWAYS DURINGCONSTRUCTION OPERATIONS. FACADE WORK BEING DONE... | $2,500 | $0 | Aug 2, 1999 |