ECB violations
65-67 Clermont Avenue, Brooklyn • Block 02046 • Lot 0037
45 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 12, 2024 | 39116660N | RESOLVE | CLASS - 1 | I OBSERVED IN THE ROOFTOP ELEVATOR DISCONNECT THE IMPROPER TAP OF THE LINE SIDE CONDUCTORS TO SUPPLY POWER TO A 2-CIR... | $2,400 | -$7,400 | Aug 15, 2025 |
| Jun 12, 2024 | 39116661P | ACTIVE | CLASS - 1 | UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39109751N 1SSUED ON 03/25/2024 AND FILE ... | $2,500 | $0 | Jul 21, 2025 |
| Mar 25, 2024 | 39109752P | RESOLVE | CLASS - 2 | I OBSERVED IN THE ELEVATOR MACHINE ROOM THE INSTALLATION OF A CIRCUIT BREAKER ENCLOSURE SUPPLYING POWER TO THE CAB LI... | $400 | $0 | Oct 10, 2024 |
| Mar 25, 2024 | 39109751N | ACTIVE | CLASS - 1 | I OBSERVED THE CONDUCTORS SUPPLYING POWER TO A TWO CIRCUIT ENCLOSURE TAPPED ON THE LINE SIDE OF THE ELEVATOR DISCONNE... | $4,800 | $0 | Oct 10, 2024 |
| Mar 25, 2024 | 39109750L | RESOLVE | CLASS - 2 | I OBSERVED IN THE CAFETERIA AND IN THE LOBBY ENTRANCE THE UNPERMITTED USE OF FLEXIBLE CORDS PASSING THROUGH THE WALL ... | $400 | $0 | Jun 5, 2024 |
| Jan 30, 2024 | 39104737Y | RESOLVE | CLASS - 2 | HOLE PENETRATION IN CEILING OF ELECTRICAL MECHANICAL ROOM, AND SEVERAL PLASTIC ACCESS PANALS IN THE CEILING OF THE LA... | $1,250 | $0 | Aug 23, 2024 |
| Jan 30, 2024 | 39104738X | RESOLVE | CLASS - 2 | RESIDENTIAL GAS FLEX HOSE PIPING INSTALLED AND UTILIZED FOR GAS CONNECTION FOR 3 DRYERS, BEYOND ALLOWED CAPACITY BY F... | $1,250 | $0 | Apr 10, 2024 |
| Mar 3, 2020 | 39018797P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER- OBSERVED AT THE ABOVE ADDRESS PEX TUBING IS BEING USED FOR DOM... | $312 | $0 | Jul 8, 2020 |
| Sep 9, 2019 | 35428565M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35415220Y ISSUED ON 04/17/19 & TO FILE A C OF C PURSUAN... | $2,500 | $0 | Jul 30, 2020 |
| Apr 19, 2019 | 35293810L | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BUILDING DEPT. RECORDS.NOTED AT CELLAR,ACCESSORY USE/RECREATIONAL... | $0 | $0 | Jan 13, 2020 |
| Apr 17, 2019 | 35415221X | RESOLVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.OBSERVED AT EXP#2 THE FIRE DEPT.CONNECTION RELOCATED FROM EXP#1... | $2,500 | $0 | Jan 16, 2020 |
| Apr 17, 2019 | 35415220Y | RESOLVE | CLASS - 1 | WORK W/O A PERMIT.OBSERVED AT EXP#2 ON PARK AVENUE THE FIRE DEPT.CONNECTION RELOCATED FROM EXP#1 ON CLERMONT AVENUE W... | $2,500 | $0 | Jan 16, 2020 |
| Nov 3, 2017 | 35274188R | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS # 352874... | $400 | $0 | Dec 18, 2017 |
| Sep 15, 2017 | 35277668J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUM/VIO#35272343Z ISSUED ON 08/01/17 & TO FILE A C OF C PURSUANT TO... | $400 | $0 | Oct 30, 2017 |
| Aug 7, 2017 | 35287432M | RESOLVE | CLASS - 2 | SEC. 358.30 EMT NOT PROPERLY SUPPORTED OBSERVED IN ELECTRICAL ROOM EMT CONDUIT FROM SERVICE END LINE (BODY)TO EQUIPME... | $400 | $0 | Sep 18, 2017 |
| Aug 1, 2017 | 35272344K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345. NOTED: OBSERVED AT CELLARS G... | $250 | $0 | Sep 18, 2017 |
| Aug 1, 2017 | 35272343Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANENR. USE OF PROHIBITED DOOR &/OR HARDWARE PER BC 1008.1.8;27-371(J). NO... | $1,000 | $0 | Sep 18, 2017 |
| Aug 1, 2017 | 35287256M | RESOLVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.OBSERVED FROM DOB RECORDS THAT TESTS HAVE NOT BEEN PERFORMED ON... | $0 | $0 | Nov 27, 2017 |
| Aug 1, 2017 | 35287255K | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED IN CELLAR TWO SPLIT SYSTEM AIR HANDLERS(HEATING/COOLING SYSTEMS)INSTALLED WITH GAS SUP... | $0 | $0 | Dec 13, 2017 |
| Aug 1, 2017 | 35287431K | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/OUT PERMIT. OBSERVED 2 HVAE HEATING/COOLING, UNITS IN DINING AREA W/ WALL, MOUNTED SERVICE DISCONNE... | $800 | $0 | Jan 22, 2018 |
| Aug 1, 2017 | 35287430Z | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS,DEVICE,APPLIANCE OR WIRING IN USE. OBSERVED SER... | $1,600 | $0 | Nov 27, 2017 |
| Aug 1, 2017 | 35287257Y | RESOLVE | CLASS - 1 | FGC403.10.4.MISC.VIOLATIONS HEXAGON BUSHING PROHIBITED ON GAS PIPING.OBSERVED HEXAGON BUSHING INSTALLED ON GAS PIPING... | $0 | $0 | Dec 13, 2017 |
| Mar 1, 2017 | 35234789X | RESOLVE | CLASS - 1 | RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT. OBSERVED ON 03/01/17 AT ABOVE ADDRESS RESIDENTIAL GAS FLEX INSTALL... | $1,600 | $0 | Jul 3, 2017 |
| Nov 18, 2016 | 35188165N | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV#35200979M ISSUED ON 09/13/16 AND TO FILE A CERTIFICATE OF C... | $2,400 | $0 | Jan 9, 2017 |
| Sep 13, 2016 | 35200973K | RESOLVE | CLASS - 3 | OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY.CO#301050494 INDICATES THE BUILDING TO BE OCCUPIED AS ... | $0 | $0 | Nov 22, 2016 |
| Sep 13, 2016 | 35200974M | RESOLVE | CLASS - 1 | WORK W/O A PERMIT.WORK NOED AT CELLAR LEVEL INSTALLED WATER AND WASTE LINES,GAS LINES, AND ELECTRICAL LINES/OUTLETS F... | $1,600 | $0 | Oct 31, 2016 |
| May 29, 2009 | 34780012Z | RESOLVE | CLASS - 1 | NEW BUILDING OCCUPIED W/O A VALID C OF O. NOTED: NB ERECTED AS PER #301050494 HAS EXPIRED & BUILDING OCCUPIED. REMEDY... | $800 | $0 | Jul 29, 2010 |
| Nov 19, 2008 | 34739753L | RESOLVE | CLASS - 1 | NEW BLDG OR OPEN LOT OCCUPIED W/O A VALID C OF O. NOTED: NEW BLDG CONST UNDER PERMIT WITH # 301050494 W/TEMPORARY C O... | $800 | $0 | Sep 24, 2009 |
| Apr 30, 2007 | 34564767K | RESOLVE | Non-Hazardous | NEW BLDG OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCY.NOTE:NEW BLDG ERECTED UNDER PERMIT#301050494.TEMPORARY C OF O ... | $700 | $0 | Jun 25, 2007 |
| Mar 3, 2006 | 34487567J | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLANS. NON-CONFORMING WORK NOTED: NB301050494 INDICATES PARKING AREA AT REAR TO BE ... | $2,500 | $0 | Nov 6, 2006 |
| May 27, 2004 | 34436674P | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY C OF O#30105049406 ISSUED 04/28/04 EXPIRES 07/28/0... | $800 | $0 | Sep 20, 2004 |
| Jan 15, 2004 | 34412709J | RESOLVE | Non-Hazardous | NEW BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. NOTED: TEMPORARY CERTIFICATE OF OCCUPANCY NUMBER 3010... | $2,500 | $0 | Mar 1, 2004 |
| Jul 23, 2003 | 34399729N | RESOLVE | Non-Hazardous | OUTDOOR AD CO HAVING AN IDENTIFICATION SING WITH AN AREA MORE THAN 12 SQ FT.REMEDY:REMOVE ILLEGAL SIGNAGE | $0 | $0 | Sep 9, 2004 |
| Jul 23, 2003 | 34399728L | RESOLVE | Non-Hazardous | OUTDOOR AD CO HAVING A PROHIBITED ADVERTISING SIGN IN R6 DISTRICT. REMEDY:REMOVE ILLEGAL SIGNAGE | $5,000 | $0 | Sep 9, 2004 |
| Jul 23, 2003 | 34399731M | RESOLVE | Non-Hazardous | OUTDOOR AD CO HAVING INSTALLED A SIGN WITHOUT A PERMIT. REMEDY:REMOVE ILLEGAL WORK | $5,000 | $0 | Sep 9, 2004 |
| Jul 23, 2003 | 34399730K | RESOLVE | Non-Hazardous | OUTDOOR AD CO HAVING A SIGN EXTENDING ABOVE THE AROUND FLOOR CEILING .REMEDY:REMOVE ILLEGAL SIGNAGE | $5,000 | $0 | Sep 9, 2004 |
| Oct 21, 2002 | 34368755P | RESOLVE | Hazardous | FAILURE TO DO ADEQUATE HOUSEKEEPING: NOTED REAR OF BUILDING CONCRETE BLOCKS, WOOD AND OTHER DEBRI THROUGHOUT. REMEDY:... | $500 | $0 | Jan 30, 2003 |
| Oct 8, 2002 | 34341113N | RESOLVE | Non-Hazardous | FAILURE TO COMPLY WITH EXTERIOR STAIRS CONSISTANT RISER HEIGHTS REQUIREMENTS NOTE : AT FRONT ENTRANCE LEVEL EXIST A F... | $400 | $0 | Feb 10, 2003 |
| Oct 3, 2002 | 34335063N | RESOLVE | Non-Hazardous | WORK W/O A PERMIT. EXPIRED PERMIT. NOTED : ACCORDING WITH D.O.B. RECORD WORK PERMIT NB- 301050494 EXPIRED : 07-15-02 ... | $500 | $0 | Feb 10, 2003 |
| Sep 25, 2002 | 34340787P | RESOLVE | Non-Hazardous | FAILURE TO COMPLY WITH LL 58/87. NOTED NEW BLDG PRIMARY ENTRANCE NOT ACCESSIBLE BY WHEEL CHAIR FROM SIDEWALK TO BLDG ... | $0 | $0 | Mar 24, 2003 |
| Aug 27, 2002 | 34322773P | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE APPROVED PLANS AT TIME OF INSPECTION. NO APPROVED PLANS ON SITE. REMEDY; STOP ALL WORK IMMEDIATELY... | $130 | $0 | Feb 10, 2003 |
| Aug 27, 2002 | 34322774R | RESOLVE | Hazardous | FAILURE TO PROPERLY STORE COMBUSTIBLE MATERIAL OR MATERIAL AND EQUIPMENT THROUHOUT 1ST FLOOR FURNITURE (EI, DRESSERS ... | $900 | $0 | Feb 10, 2003 |
| Nov 16, 2001 | 34301020H | RESOLVE | Hazardous | NO HAND RAILS ON STAIR WELL. VIOLATION NOTED: NO HANDRAILS FROM SECOND FL UP AT THE TIME OF INSPECTION WHILE WERE WOR... | $1,250 | $0 | Jan 28, 2002 |
| Nov 16, 2001 | 34301019K | RESOLVE | Hazardous | NO GUARD RAILS. VIOLATION NOTED NO GUARD RAILS AT THE ELEVATOR SHAFTS OPENINGS (PLUMBING WORN WAS IN PROGRESS) REMEDY... | $1,000 | $0 | Jan 28, 2002 |
| Jan 9, 2001 | 34273433K | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT.WORK NOTED:EXCAVATION AT VACANT LOT APPROX 9FT DEEP 45FT LONG AND 30FT WIDE.ADJACENT TO BLDG#69... | $2,500 | $0 | Feb 26, 2001 |