ECB violations
Fleet Walk, Brooklyn • Block 02050 • Lot 0001
81 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 27, 2025 | 35685730Y | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. AS NOTED: AT TIME OF INSPECTION, OBSERVED ALL UNITS INSTALLED AT ... | $2,500 | $0 | Oct 31, 2025 |
| Sep 25, 2025 | 39545324J | RESOLVE | CLASS - 2 | SIDEWALK SHED INSTALLED AT ALL EXPOSURE CONTRARY TO CODE SPECIFICATION, OBSERVED MULTIPLE HORIZONTAL MEMBERS UNDER SI... | $2,400 | $0 | Dec 3, 2025 |
| May 6, 2025 | 39539866N | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION I OBSERVED, TWO MISSING PARAPET PANELS ON SHED AT EXPOSURE#1 INSIDE GATED AREA. I ALSO OBSE... | $2,400 | $2,400 | Mar 2, 2026 |
| Oct 7, 2024 | 39533162H | ACTIVE | CLASS - 2 | BC3307.6.4.4 AT THE TIME OF INSPECTION OF 6-STORY OCCUPIED MULTI-FAMILY BUILDING FACADE REPAIR IN PROGRESS, OBSERVED ... | $2,400 | $2,400 | Jun 15, 2026 |
| Apr 26, 2024 | 35681791J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXPOSURE #... | $1,250 | $0 | May 13, 2024 |
| Apr 26, 2024 | 35681794P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXPOSURE #... | $1,250 | $0 | May 13, 2024 |
| Apr 26, 2024 | 35681793N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES.-NOTE: AT TIME OF INSPECTION, I OBSERVED EXPSOURE #2 E... | $2,500 | $0 | May 13, 2024 |
| Apr 26, 2024 | 35681795R | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED A HORIZONTAL ... | $1,250 | $0 | May 13, 2024 |
| Nov 3, 2023 | 39523159H | RESOLVE | CLASS - 2 | OBSERVED OVERHEAD PROTECTION (SIDEWALK SHED) ABOVE A WALKWAY AT EXP#2, WITH THE LATERAL CROSS-BRACING NEAR THE TOP OF... | $0 | $0 | Jan 10, 2024 |
| Nov 3, 2023 | 39523129R | RESOLVE | CLASS - 1 | MANUFACTURER SPECIFICATIONS. OBSERVED 2 SUSPENDED SCAFFOLD PLATFORMS (1 IN USE AT EXP#3) WITH THE PLATFORM ARRANGEMEN... | $2,500 | $0 | Jan 10, 2024 |
| Nov 3, 2023 | 39523128P | RESOLVE | CLASS - 1 | OBSVD OUTRIGGER BEAM SUSPENDED SCAFFOLDS AT ALL EXPS WITH CONDITIONS CONTRARY TO CD5- LIFELINES + TIE-BACK LINES NOT ... | $2,500 | $0 | Jan 10, 2024 |
| Oct 2, 2023 | 39522272P | RESOLVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OF A 11 STORY BUILDING, I OBSERVED SUPPORTED PIPE SCAFFOLD AT EXPOSURE #3 WITH A DEBRIS ... | $2,500 | $0 | Jun 3, 2024 |
| May 23, 2023 | 39518187Z | RESOLVE | CLASS - 1 | -WORKER INJURED DUE TO FALLEN DEBRIS FROM ROOF, TAKEN TO OFF SITE MEDICAL FACILITY. PERMIT HOLDER JOB#321229915 FAILE... | $2,500 | $0 | Sep 6, 2023 |
| May 17, 2023 | 39086550H | RESOLVE | CLASS - 2 | RESPONDING TO ACCIDENT WHERE WORKER WAS STRUCK BY BRICK FROM 11TH FLOOR NO 16HR SS CARD FOR WORKER STRUCK, WORKER ON ... | $1,250 | $0 | Sep 27, 2024 |
| May 17, 2023 | 39086548Z | RESOLVE | CLASS - 1 | NOTED WORKER WAS STRUCK BY DEBRIS FALLING FROM 11TH FLOOR WHILE SHE WAS ON SECOND FLOOR SHED. WORKER WAS TAKEN TO HOS... | $0 | $0 | Sep 27, 2024 |
| Apr 3, 2023 | 39514924L | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION WHILE RESPONDING, TO A COMPLAINT CONCERNING AN UNSAFE SCAFFOLD ON THE JOBSITE, I OBSERVED A... | $625 | $0 | Nov 27, 2023 |
| Apr 3, 2023 | 39514916L | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION WHILE RESPONDING, TO A COMPLAINT CONCERNING AN UNSAFE SCAFFOLD ON THE JOBSITE, I OBSERVED A... | $625 | $0 | Nov 27, 2023 |
| Oct 28, 2022 | 39508344Y | RESOLVE | CLASS - 2 | ACTIVE SITE- GC WORKING ON EXTERIOR RAMP. UPON REQUEST, WORKER SAFETY ORIENTATIONS AND PRE-SHIFT SAFETY MEETINGS WERE... | $0 | $0 | Mar 1, 2023 |
| Apr 27, 2022 | 39500982M | RESOLVE | CLASS - 1 | PLATFORM 19, 20 LENGTH AT EXP#3 NOT SETUP AS PER CD5 INSTALLED ONE PLATFORM WITH ~44' LONG WITH ONLY 2 OUTRIGGERS INS... | $2,500 | $0 | Aug 31, 2022 |
| Mar 7, 2022 | 39057560Z | RESOLVE | CLASS - 2 | FOUND EASCO BOILER MODEL #FPS 350-50 WITH KING VALVE LEAKING ABOVE BOILER AND LEAK AT CONDENSATE PUMP PIPING IN BOILE... | $625 | $0 | Mar 7, 2022 |
| May 21, 2021 | 35540948J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTE:TIME OF INSPECTION IT WAS OBSERVED THE CONTRA... | $2,500 | $0 | Sep 29, 2021 |
| Apr 6, 2021 | 35491541J | RESOLVE | CLASS - 1 | WORK W/OUT PERMIT.NOTE:AT THE TIME OF MY INSPECTION OF A 6 STORY,FACADE RESTORATION BLDG,I OBSERVED A CHUTE OF OVER 6... | $2,500 | $0 | Aug 18, 2021 |
| Mar 20, 2020 | 35538104R | RESOLVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE ADEQUATE SAFTEY MEASURE SUCH AS SIDE WALK SHED FENCE ECT WHERE REQUIRED TO PROTECT AND SE... | $10,000 | $0 | Sep 2, 2020 |
| Mar 20, 2020 | 35538106K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUIDLINGS EXTERIOR WALLS FACADE AND APPURTENANCES AT THE TIME OF INSEPCTION OBSERVED AIR CONDITIO... | $1,250 | $0 | Sep 2, 2020 |
| Mar 19, 2020 | 35538108Y | RESOLVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SIDEWALK SHED FENCE ECT.WHERE REQUIRED TO PROTECT AND SE... | $10,000 | $0 | Sep 16, 2020 |
| Feb 26, 2019 | 35385772H | RESOLVE | CLASS - 1 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER RULE. NOTED:AT TIME OF MY INSPECTION OF AN ALTERATION 2 W... | $0 | $0 | Jun 10, 2019 |
| Feb 26, 2019 | 35385771X | RESOLVE | CLASS - 2 | 1RCNY 3301-02(D) CONSTRUCTION SUPERINTENDENT FAILS TO MAINTAIN AND/OR MAKE JOB SITE LOGS AVAILABLE. NOTED:AT TIME OF ... | $0 | $0 | Jun 10, 2019 |
| Oct 15, 2018 | 37012687Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012676Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012691R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012657N | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURT... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012747R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012679Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012681N | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012662H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURT... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012677K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012692Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012652Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURT... | $0 | $0 | Mar 18, 2019 |
| Oct 15, 2018 | 37012683R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $0 | $0 | Mar 18, 2019 |
| Aug 7, 2018 | 39000024H | RESOLVE | CLASS - 2 | 20180816 | $0 | $0 | Aug 16, 2018 |
| Aug 7, 2018 | 39000023X | RESOLVE | CLASS - 2 | 20180816 | $0 | $0 | Aug 16, 2018 |
| Aug 7, 2018 | 39000235H | RESOLVE | CLASS - 2 | THIS IS A TEMPORARY BOILER CONNECTED TO THIS BUILDING FRESH AIR FAN IS DEFECTIVE SAIL SWITCH IS DEFECTIVE LIGHTS DEFE... | $3,125 | $0 | Sep 5, 2018 |
| Aug 7, 2018 | 39000228J | RESOLVE | CLASS - 2 | THIS IS A TEMPORARY BOILER CONNECTED TO BUILDING GAS PIOLIT REGULATOR DEFECTIVE FRESH AIR FAN DEFECTIVE SAIL SWITCH D... | $3,125 | $0 | Sep 5, 2018 |
| Mar 22, 2016 | 35157924N | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE. EXPIRED PERMIT. NOTED:AT TIME OF INSPECTION THERE IS A SIDEWALK SHED ON EXP... | $2,000 | $0 | May 9, 2016 |
| Jul 16, 2010 | 36014342L | RESOLVE | CLASS - 2 | FAIL TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED... | $0 | $0 | Aug 16, 2010 |
| Jul 16, 2010 | 36014343N | RESOLVE | CLASS - 2 | FAIL TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED... | $0 | $0 | Aug 16, 2010 |
| Jul 16, 2010 | 36014344P | RESOLVE | CLASS - 2 | FAIL TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED... | $0 | $0 | Aug 16, 2010 |
| Feb 12, 2010 | 34837138Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SIDEWALK SHED OR SAFETY MEASURES WHERE REQUIRED ACCORDING TO THE CYCLE #6 TECHNICAL REPORT (TR6) F... | $0 | $0 | Apr 5, 2010 |
| Feb 12, 2010 | 34837139K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SAFETY MEASURES OR SIDEWALK SHED WHERE REQUIRED ACCORDING TO THE CYCLE #6 TECHNICAL REPORT(TR6) FI... | $0 | $0 | Apr 5, 2010 |
| Feb 12, 2010 | 34837137R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SIDEWALK SHED OR SAFELY MEASURES WHERE REQUIRED ACCORDINGLY TO THE CYCLE #6 TECHNICAL REPORT (TR6)... | $0 | $0 | Apr 5, 2010 |