ECB violations
Kent Avenue, Brooklyn • Block 02159 • Lot 0002
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 2, 2024 | 39129318K | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. AT TIME OF INSPECTION, OBSERVED CHAIN LINK FENCE IN STATE OF D... | $6,250 | $6,250 | Jan 15, 2025 |
| Nov 2, 2024 | 39129317Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS.... | $3,125 | $3,125 | Jan 15, 2025 |
| Nov 2, 2024 | 39129315P | ACTIVE | CLASS - 1 | WORK WITHOUT PERMIT. AT TIME OF INSPECTION, OBSERVED LARGE OFFICE TRAILER WITH WOOD FRAME EXTENSION APPROX. 30'FT(W) ... | $12,500 | $12,500 | Jan 15, 2025 |
| Nov 2, 2024 | 39129316R | ACTIVE | CLASS - 1 | FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4. PARTIAL VACATE ORDER #B146/22 EXIST ON PROPERTY, W... | $24,000 | $24,000 | Jan 15, 2025 |
| Nov 2, 2024 | 39129319M | ACTIVE | CLASS - 3 | FENCE EXCEEDS PERMITTED HEIGHT. AT TIME OF INSPECTION, OBSERVED CHAIN LINK FENCE EXCEEDED ITS MAXIMUM HEIGHT REQUIREM... | $500 | $500 | Jan 15, 2025 |
| Apr 29, 2022 | 39061359Z | ACTIVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BUILDING DEPARTMENT RECORDS : DEPARTMENTAL RECORDS INDICATES PARK... | $1,250 | $1,250 | Nov 18, 2022 |
| Apr 29, 2022 | 39061360X | RESOLVE | CLASS - 2 | WORK WITH OUT A PERMIT: NOTE AT DIVISION AVE, (2) CC APPROX..72'L & 52'L WITH SPLAYS, 15FT (H) GATE AND A ATTACHED DO... | $0 | $0 | Nov 18, 2022 |
| Jan 5, 2017 | 35184185M | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION PLANS/DOCUMENTS &/OR APPROVED AMENDMENTS. UNDER ALT-2 320323146. NOTED... | $500 | $0 | Feb 27, 2017 |
| Jan 10, 2012 | 34971447J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERT OF CORRECTION WITH THE DOB FOR NOTICE OF VIOLATION #34... | $800 | $0 | Oct 15, 2012 |
| Jan 10, 2012 | 34971182N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C OF C W/THE DEPT OF BUILDINGS FOR NOTICE OF VIOLATION #349006... | $2,000 | $0 | Dec 3, 2012 |
| Jul 20, 2011 | 34896237Y | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.RE:INSTALLATION/MAINTENACE OF PLUMBING MATERIALS/EQUIPMENT PER PC 102.... | $500 | $0 | Sep 12, 2011 |
| Jul 20, 2011 | 32070306P | RESOLVE | CLASS - 2 | 28-301.1 (B254),16,19B,32A,50,50A,36,50B,44C,50C. 50-MISSING SPILL SWITCH ON BOILER FLUE DIVIDER. 50A-DEBRIS ON BOILE... | $500 | $0 | Sep 12, 2011 |
| Jul 20, 2011 | 32070307R | RESOLVE | CLASS - 2 | 28-301.1 2(B254),16,19B,50,50A,50B,36,50C. 50-MISSING BOILER DRAIN VALUE. 50A-MISSING SPILL SWITCH ON FLUE PIPE DIVER... | $500 | $0 | Sep 12, 2011 |
| Jul 20, 2011 | 38217431X | RESOLVE | CLASS - 1 | CU46-N-10/42-R-09/100-#-#/41-D-06/41-B-07/100-M-07/68-M-07/46-N-10-CEASE USE GOVERNOR SWITCH BY PASSED REAPIR/42-R-09... | $1,000 | $0 | Dec 22, 2011 |
| Jul 20, 2011 | 32070305N | RESOLVE | CLASS - 2 | 50E,50F,28-301.1,50B,15,50C,16,50D,32A,19B,50,50A,36. 50E# MISSING FUSABLE LINK FIVE DAMPER TO FRESH AIR INTAKE IN BO... | $500 | $0 | Sep 12, 2011 |
| Jul 20, 2011 | 34900689Y | RESOLVE | CLASS - 1 | OPERATION OF A PA W/O A CURRENT C/O. AT TIME OF INSPECTION OBSERVED AT1ST FLR THE ARRANGEMENT OF A PA W/TABLE & CHAIR... | $25,000 | $0 | Jul 25, 2012 |
| Jul 20, 2011 | 34900685R | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. AT TIME OF INSPECTION OBSERVED WORK PERFORMED AT PREMISES W/O PERMITS. ILLEGAL WORK NOTED: ERECTIO... | $4,000 | $0 | May 2, 2012 |
| Jul 20, 2011 | 34900688M | RESOLVE | CLASS - 2 | ALTERED/CHANGED BLDG OCCUPIED W/O A VALID C/O AS PER 28-118.3.1-28-118.3.2. ALT TYPE 1 JOB #310076618 FILED TO CONVER... | $2,500 | $0 | Sep 12, 2011 |
| Aug 3, 2010 | 34853645N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS. NOTE:... | $800 | $0 | Oct 21, 2010 |
| Aug 3, 2010 | 34853644L | RESOLVE | CLASS - 2 | FAILED TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS. NOTE: ... | $800 | $0 | Oct 21, 2010 |
| Dec 14, 2009 | 34811067P | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O NOTED C/O #197200 INDICATES LEGAL USE IS THAT OF WAREHOUSE CELLAR TO 4TH FL... | $2,400 | $0 | Nov 22, 2010 |
| May 20, 2009 | 34767465P | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O NOTED: C/O #197200 INDICATES, LEGAL OCCUPANCY, FLOORS CELLAR- 4THFLOOR AS W... | $2,400 | $0 | Jun 23, 2010 |
| Jan 21, 2008 | 32055737L | RESOLVE | Hazardous | B4B364A19B50A32A50B50C50D50E50F50G. 50A NO BOILER ROOM ENCLOSURE. 50B NO VALVE ON EXPANSION TANK. 50C HOLES IN BOILER... | $800 | $0 | Jul 10, 2008 |
| Jan 21, 2008 | 32055736J | RESOLVE | Hazardous | B4BBQ94A19B3632A50A50B50C50D50E50F50G50H. 50A NO BOILER ROOM ENCLOSURE50B NO VALVE ON EXPANSION TANK. 50C NO FIT FRES... | $1,300 | $0 | Jul 10, 2008 |
| Jan 20, 2008 | 34610662Z | RESOLVE | Non-Hazardous | NOTED:FAILURE TO MAINTAIN EXTERIOR BLDG WALL NOTED:FRONT WALL OF PREMISES HAS VERTICAL CRACKS BULGING & MISSING MASON... | $800 | $0 | Jul 10, 2008 |
| Jan 20, 2008 | 34610661R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG NOTED:THE SPRINKLER HAS BEEN DISCONNECTED AT ABOVE PREMISES CEILINGS MISSING IN VARIOUS LOCA... | $800 | $0 | Jul 10, 2008 |
| Jan 20, 2008 | 34610660P | RESOLVE | Non-Hazardous | WORK W/O A PERMIT NOTED: PARTITIONS HAVE BEEN ERECTED ON ALL LEVEL CREATING CLASSROMMS ABOVE 1ST FL 2 KITCHENS ON 1ST... | $500 | $0 | Jul 10, 2008 |