Skip to content

ECB violations

189-193 Ross Street, Brooklyn • Block 02183 • Lot 0058

25 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Oct 21, 2022 39072436R RESOLVE CLASS - 2 STORAGE@BLR ROOM/STORAGE SHED@YARD BLOCKING CHIMNEY BASE ACCESS DOOR/OLD/UNUSED HW BLR NOT LEGALLY ABANDONED/BLDG WAT... $0 $0 Feb 22, 2023
Aug 19, 2020 39027218X RESOLVE CLASS - 1 I OBSERVED IN BASEMENT LAUNDRY ROOM SEVERAL COMMERCIAL GAS DRYERS WITH NO SPRINKLER COVERAGE WHICH THEREFORE IS NO FI... $2,500 $2,500 Jul 2, 2021
Aug 19, 2020 39027219H RESOLVE CLASS - 1 I OBSERVED IN BASEMENT SEVERAL COMMERCIAL GAS DRYERS WITH GAS FLEX CONNECTORS INSTALLED ON GAS DRYERS WHICH IS PROHIB... $1,250 $1,250 Jul 2, 2021
Oct 11, 2017 38258036R RESOLVE CLASS - 2 05B01,67X10,35Q03,39X10,60X10,60Q03,57M07,40Q03,100M07,70O02,71X10-05B01)ADJUST CAR DOOR OPENING(TOO SLOW). 67X10)REP... $500 $0 Nov 27, 2017
Mar 27, 2017 38253598X RESOLVE CLASS - 2 44R05 NO RECORD OF APPLICATION/SIGN OFF FOR REGROOVED SH $800 $0 Sep 27, 2017
Mar 27, 2017 38253597Y RESOLVE CLASS - 1 *05X10,*59J01,100M07,17M11,17D06,17J01,12M07,67X10,11X10,14H11,29J01,29Q03,37Y02,70O02,70Q03,76Q03,76O02,70M07,61G11,... $1,000 $0 Jul 26, 2017
Nov 7, 2016 38250166Z RESOLVE CLASS - 1 16D10/16D10-LOBBING HOISTWAY DOOR IS UNSECURE.REPAIR DOOR LOCK. $1,000 $0 Dec 28, 2016
Nov 7, 2016 38250168M RESOLVE CLASS - 2 16M07/16M07-PROVIDE MISSING ECCENTRICS $250 $0 Mar 6, 2017
Sep 15, 2016 35199665N RESOLVE CLASS - 1 3314 FAILURE TO HAVE BUILT ACCORDING TO CODE SPECIFICATION PARTIAL STOP WORD ON SUPPORTED SCAFFOLD AND MATERIAL HOIST... $1,600 $0 Apr 19, 2017
Sep 15, 2016 35199666P RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOESNT MEET CODE SPECIFICATIONS.NOTE:AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE AT... $0 $0 Apr 21, 2017
Sep 15, 2016 35199664L RESOLVE CLASS - 2 FAILURE TO PROVIDE ADEQUATE HOUSE KEEPING.NOTE:AT TIME OF INSPECTION IOBSERVED A LARGE AMOUNT OF CONSTRUCTION DEBRIS ... $0 $0 Oct 31, 2016
Dec 29, 2015 35160977Y RESOLVE CLASS - 2 SEC. 3307.6.5 FAILURE TO MAINTAIN ADEQUATE ILLUMINATION BENEATH SIDEWALK SHED AS REQUIRED BY CODE. NOTED: SIDEWALK SH... $0 $0 Feb 22, 2016
Jan 19, 2011 34896908X RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION W/THE DEPT OF BUILDINGS RESPONDENT F... $800 $0 Nov 7, 2011
Dec 16, 2010 34893130K RESOLVE CLASS - 1 FAILURE TO CORRECT CONDITIONS CITED IN NOV 34876608X FOR OBSTRUCTING PASSAGEWAY OF BUILDING. REMEDY: CORRECT CONDITIO... $2,400 $0 Apr 27, 2011
Dec 16, 2010 34893129N RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT. MANNER PROVIDE REQUIRED CORRIDOR WIDTH PER BC 1016.2;27-369. NOTED: L... $1,250 $0 Apr 27, 2011
Nov 10, 2010 34874517L RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: WIDTH OF THE EXIT PASSAGEWAY REDUCED THROUGHOUT THE ENTIRE 6 S... $400 $0 Nov 7, 2011
Sep 11, 2010 34876608X RESOLVE CLASS - 1 FAIL TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE:STROLLERS & TOYS OBSERVED STORED ON THE STAIRWAY,LANDINGS & ENTRY ... $1,200 $0 Apr 27, 2011
Apr 23, 2010 34839491Z RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTE:CHILDREN STROLLERS & TOYS OBSERVED BEING STORED IN THE 1ST,2ND &... $3,000 $0 Oct 7, 2010
Oct 22, 2009 34811518P RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: CHILDREN STROLLERS (7-8) ARE BEING STORED IN PUBLIC HALL, STAI... $1,200 $0 Oct 7, 2010
Aug 26, 2009 38205806P RESOLVE CLASS - 3 02L11,03I10,05L10,07L10,08V01,14M07,15M07,16L07,21M07,23I11,24I11,97O02 21-MISSING COVERS. $100 $0 Mar 22, 2010
Apr 19, 2000 34242840X RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. WORK NOTED AT FIRST STORY NORTH IN APARTMENT IC IS BEING USED FOR BUSINESS FOR THE SALES OF FL... $2,500 $0 Sep 11, 2000
Dec 12, 1998 38082704R RESOLVE Non-Hazardous 28H11,7X11,35P7,75U5,74O2. 75-PERFORM 5 YR TEST & TAG (TOP OF CAR NOTTAGGED). 74-CLEAN TOP OF CAR & PROVIDE COVERS. $0 $0 Feb 1, 1999
Jul 2, 1998 34182623H RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: BRICK WORK AT THE 4TH STORY LEFT SIDE FIRE ESCAPE WINDOWS IS C... $2,500 $0 Aug 17, 1998
Mar 23, 1998 38072094J RESOLVE Non-Hazardous 75U5,8V1,30O2,57O2. 75-PERFORM 5 YEAR TEST. 8-ADJUST FL STOP. $2,500 $0 Jun 8, 1998
Sep 19, 1992 38028406L RESOLVE Non-Hazardous 73#. 5YR. TEST PEFORM 5YR. TEST AND FILE FORM. $1,000 $0 Nov 2, 1992