ECB violations
642 Bedford Avenue • Block 02210 • Lot 0039
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 30, 2016 | 35218765L | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. @ TIME OF INSP OBSERVED AN ACTIVE CONSTRUCTION SITE C... | $0 | $0 | Jan 24, 2018 |
| Jun 23, 2016 | 35175296K | RESOLVE | CLASS - 1 | WORK DOESN'T CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVED AMENDMENTS.@TIME OF INPSECTION IT WAS OBSERVED ... | $0 | $0 | Mar 20, 2017 |
| Jun 23, 2016 | 35178162Z | RESOLVE | CLASS - 1 | NO GUARDRAILS/INADEQUATE GUARDRAIL SYSTEM.NOTED:ACTIVE CONSTRUCTION SITE.GUARDRAILS ERECTED @ELEVATOR SHAFT OPENING N... | $1,200 | $0 | Mar 15, 2017 |
| Jun 23, 2016 | 35158390M | RESOLVE | CLASS - 1 | 3314.5 PLATFORM ON ALL WORKING LEVELS OF A SCAFFOLD SHALL BE FULLY PLANKED.NOTED:@TIME OF INSPECTION THERE ARE WORKIN... | $1,600 | $0 | Feb 24, 2017 |
| Jun 23, 2016 | 35158393H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS CONSTRUCTION DOCUMENTS @JOBSITE @TIME OF INSPECTION.NOTED:@TIME OF INSPECT... | $250 | $0 | Jun 30, 2017 |
| Jun 23, 2016 | 35175297M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS @JOBSITE @TIME OF INSPECTION.@TIME OF INSPECTION IT WAS OBSERVED THAT A CO... | $250 | $0 | Jun 30, 2017 |
| Jun 23, 2016 | 35158391Y | RESOLVE | CLASS - 2 | 3314.8.2 DEBRIS NETTING. SUCH NETTING SHALL BE SECURELY ATTCHED TO THESCAFFOLD &SHALL ENCLOSE ALL OPEN SIDE&ENDS OF S... | $4,000 | $0 | Aug 8, 2016 |
| Jun 23, 2016 | 35158389P | RESOLVE | CLASS - 1 | 3314.4.3.3 SUPPORTED SCAFFOLD ALL COMPONDENTS OF &ATTCHMENTS TO THE SCAFFOLD,& ALL SUPPORTS &ANCHORAGES OF THE SCAFFO... | $1,600 | $0 | Feb 24, 2017 |
| Jun 23, 2016 | 35178159H | RESOLVE | CLASS - 1 | 3301.1.2 FAILURE TO COMPLY W.NYC FIRE CODE-NO PERMIT FOR OXYGEN &ACETYLENE.NOTED:2CYLINDERS OF ACETYLENE &2 OXYGEN CY... | $1,600 | $0 | Mar 15, 2017 |
| Jun 23, 2016 | 35178161R | RESOLVE | CLASS - 1 | 3301.7 DESIGN DRAWING.NOTED:VERTICAL ENLARGEMENT OF THE BLDG IN PROGRESS.WORK PLATFORM ERECTED IN ELEVATOR SHAFT FROM... | $1,000 | $0 | Mar 15, 2017 |
| Jun 23, 2016 | 35158388N | RESOLVE | CLASS - 1 | 3314.8 PSWO SUPPORTED SCAFFOLD GUARDRAIL SYSTEM THE OPEN SIDES &ENDS OF SCAFFOLD PLATFORMS SHALL BE PROVIDED W. A GUA... | $1,600 | $0 | Feb 22, 2017 |
| Jun 23, 2016 | 35158392X | RESOLVE | CLASS - 1 | 3314.6 THE FOOTINGS &ANCHORAGE FOR EVERY SCAFFOLD SHALL BE SOUND AND RIGID.NOTED:@TIME OF INSPECTION SCAFFOLD IS ABT ... | $1,600 | $0 | Feb 24, 2017 |
| Jun 23, 2016 | 35178165Y | RESOLVE | CLASS - 1 | BC3313.1-COMBUSTIBLE LIQUID NOT STORED PROPERLY. NOTED: 4 CYLINDERS OF ACETYLENE AND OXYGEN(2 AND 2)ON SITE, NOT STOR... | $1,600 | $0 | Mar 15, 2017 |
| Jun 23, 2016 | 35178160P | RESOLVE | CLASS - 1 | 3309.10 NO ROOF PROTECTION.NOTED:ENLARGEMENT(VERTICALLY)IN PROGRESS.NOROOF PROTECTION IN PLACE @EXP#4 (640BEDFORD AVE... | $0 | $0 | Mar 6, 2017 |
| Jun 23, 2016 | 35178163K | RESOLVE | CLASS - 1 | 28-109.8.4 TENANT PROTECTION PLAN.NOTED:ACTIVE CONSTRUCTION SITE(VERTICAL ENLARGEMENT)ADJACENT BLDGS(644-KINDERGARDEN... | $0 | $0 | Mar 15, 2017 |
| Apr 15, 2015 | 35108889X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.NOTE: AT TIME OF MY INSPECTION OF A STEEL FRAME BLDG UP TO ROOF LEVEL... | $4,800 | $0 | Aug 24, 2015 |
| Apr 15, 2015 | 35108890N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.NOTE: AT TIME OF MY INSPECTION OF A ... | $2,400 | $0 | Aug 24, 2015 |
| Jul 2, 2014 | 35067440H | RESOLVE | CLASS - 2 | 3309.6 FAIL TO MONITOR ADJOINING STRUCTURE FOR MOVEMENT IN ALL DIRECTION DURING EXCAVATION RELATED ACTIVITY THAT MAY ... | $0 | $0 | Aug 18, 2014 |
| Jul 2, 2014 | 35067441J | RESOLVE | CLASS - 2 | 28-104.7.7 FAIL TO FILE TR1 FORM & DESIGNATE OPERATIONS SUBJECT TO CONTROLLED INSP(SPECIAL INSP)ON PLANS PRIOR TO THE... | $0 | $0 | Aug 18, 2014 |
| Jul 2, 2014 | 35067442L | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONST DOC & OR APPROVED AMEND.NOTED :@ TIME OF INSP WORK DID NOT CONFORM TO PLANS O... | $0 | $0 | Aug 18, 2014 |