ECB violations
112 Walton Street, Brooklyn • Block 02250 • Lot 0023
22 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 13, 2020 | 39017574N | RESOLVE | CLASS - 1 | APPROXIMATELY 30 FEET OF 3 INCH WASTE LINE REPLACED IN CELLAR OF REAR BUILDING. NO PERMITS ON FILE FOR WASTE LINE REP... | $0 | $0 | Jun 23, 2022 |
| Feb 13, 2020 | 39017573L | RESOLVE | CLASS - 1 | FUTURE GAS CONNECTION IN APARTMENT 1A. PROHIBITED FRENCO COUPLINGS USED ON WASTE LINE IN REAR BUILDING. WASTE LINE DI... | $0 | $0 | Jun 23, 2022 |
| Nov 15, 2019 | 39012894J | ACTIVE | CLASS - 2 | AS PER CLASS 2 ÝB265¨ 28-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS; SUBMIT THE CER... | $625 | $625 | Jan 7, 2021 |
| Oct 8, 2019 | 39010993X | RESOLVE | CLASS - 1 | I OBSERVED IN THE REAR BUILDING IN APARTMENT# 9, 8, 7 AND 6 SEVERAL GAS HEATING UNITS INSTALLED WITH FLEXIBLE CONNECT... | $0 | $0 | Aug 11, 2022 |
| Oct 8, 2019 | 35460607L | RESOLVE | CLASS - 2 | FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES CABLE ARMOR.LIGHTING RACEWAY IN REAR OF... | $0 | $0 | Jan 3, 2022 |
| Oct 8, 2019 | 35460609P | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ARC FAULT CIRCUIT INTERRUPTER(AFCI)PROTECTION IN DWELLING UNITS.NO AFCI PROTECTION PROVIDED IN APA... | $0 | $0 | Jan 3, 2022 |
| Oct 8, 2019 | 39010995J | RESOLVE | CLASS - 1 | WORK WITH OUT PERMIT, AT TIME OF INSPECTION OBNSERVED THAT APARTMENT 1B HAD BEEN RENOVATED, CEILING AND WALLS THROUGH... | $0 | $0 | Aug 16, 2021 |
| Oct 8, 2019 | 35460605H | ACTIVE | CLASS - 1 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE.ARMORED CAB... | $8,000 | $8,000 | Aug 2, 2021 |
| Oct 8, 2019 | 39010996L | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS, AT TIME OF INSPECT... | $0 | $0 | Dec 6, 2021 |
| Oct 8, 2019 | 35243771M | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AND DOB RECORDS.1ST STORYAPARTMENT #1 ILLEGALLY SUBDIVIDED CREATING TWO ... | $0 | $0 | Mar 28, 2022 |
| Oct 8, 2019 | 39010992Y | ACTIVE | CLASS - 2 | I OBSERVED IN THE CELLAR AREA OF THE REAR BUILDING SEVERAL BROKEN SANITARY PIPING, DISCHARGING SANITARY WASTE ONTO TH... | $625 | $625 | Aug 11, 2022 |
| Oct 8, 2019 | 39010984Y | RESOLVE | CLASS - 1 | I OBSERVED IN APARTMENT# 5, 3 AND 1B SEVERAL GAS HEATING UNITS INSTALLED WITH FLEXIBLE CONNECTORS WHICH IS PROHIBITED... | $0 | $0 | Aug 11, 2022 |
| Oct 8, 2019 | 39010991M | RESOLVE | CLASS - 1 | I OBSERVED IN THE REAR BUILDING IN APARTMENT# 9, 8, 7 AND 6 SEVERAL GAS HEATING UNITS INSTALLED. ALL THE GAS WORK AND... | $0 | $0 | Aug 11, 2022 |
| Oct 8, 2019 | 39010990K | ACTIVE | CLASS - 1 | I OBSERVED IN THE REAR BUILDING IN APARTMENT# 9, 8, 7 AND 6 SEVERAL GAS HEATING UNITS INSTALLED. NO RECORDS AT DOB OF... | $1,250 | $1,250 | Aug 11, 2022 |
| Oct 8, 2019 | 39010983M | RESOLVE | CLASS - 1 | I OBSERVED IN APARTMENT# 5, 3 AND 1B GAS HEATING UNITS INSTALLED..ALL THE GAS WORK AND INSTALLATION WAS DONE WITHOUT ... | $0 | $0 | Aug 11, 2022 |
| Oct 8, 2019 | 35460606J | ACTIVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED AT 8AM PANEL FIXTURES SWITCHES OUTLETS INSTALLED IN APT 1B AND 5;NO ELECTRI... | $800 | $800 | Oct 4, 2021 |
| Oct 8, 2019 | 35460608N | ACTIVE | CLASS - 2 | FAILURE TO SECURE SUPPORT RACEWAYS CABLE ASSEMBLIES BOXES CABINETS FITINGS.LIGHTING RACEWAY IN REAR OF BUILDING NOT P... | $800 | $800 | Jan 3, 2022 |
| Oct 8, 2019 | 39010982K | ACTIVE | CLASS - 1 | I OBSERVED IN APARTMENT# 5, 3 AND 1B GAS HEATING UNITS INSTALLED, NO RECORDS AT DOB OF ANY TEST OR INSPECTIONS BEING ... | $1,250 | $1,250 | Aug 11, 2022 |
| Oct 8, 2019 | 39010985X | ACTIVE | CLASS - 1 | I OBSERVED IN APARTMENT# 5, 3 AND 1B GAS BEING SUPPLIED TO THE HEATING UNITS WITHOUT ANY INSPECTIONS AND CERTIFICATIO... | $2,500 | $2,500 | Aug 11, 2022 |
| Oct 8, 2019 | 39010988L | ACTIVE | CLASS - 1 | I OBSERVED IN THE REAR BUILDING IN APARTMENT# 9, 8, 7 AND 6, GAS BEING SUPPLIED TO THE HEATING UNIT WITHOUT ANY INSPE... | $2,500 | $2,500 | Aug 11, 2022 |
| Apr 4, 2017 | 35250836J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.I OBSERVED I CELLAR FILLED WITH WATER DUR TO MAINT WASTE WATER ... | $1,000 | $0 | Jul 17, 2017 |
| Jul 28, 2000 | 32019165R | ACTIVE | Non-Hazardous | 36 | $350 | $0 | Sep 11, 2000 |