63 North 10 Street, Brooklyn
Brooklyn • Block 02295 • Lot 0021 • Zip: 11249
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Union Square 19 min 5 walking, 14 riding
- Downtown Brooklyn 28 min 5 walking, 23 riding
- Grand Central 30 min 5 walking, 25 riding
- Times Square 31 min 5 walking, 26 riding
- Fulton Street 32 min 5 walking, 27 riding
- Penn Station 33 min 5 walking, 28 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Socceria
No description yet
Kelang
No description yet
Lalaon
No description yet
Le Crocodile
Le Crocodile is a chic French brasserie located in Brooklyn, NY. Known for its classic French cuisine, elegant decor,...
Lilia
Lilia is a charming Italian restaurant in Brooklyn known for its fresh handmade pasta, delicious wood-fired dishes, a...
Three Decker Diner
Diner
Taqueria Ramirez
Mexican
Nitehawk Cinema
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
New Building
REQUESTING TO FILE POST APPROVAL AMENDMENT PLANS TO ADD ADDITIONAL FLOORS AS H IGHLIGHTED IN SCHEDULE "A"
2025
2024
-
CLASS - 2
FAILURE TO MAINTAIN BUILDING'S EXTERIOR WALLS AND/OR APPURTENANCES.-ATTIME OF INSPECTION OBSERVED CRACKED/SPALLED CON...
-
Alteration Type III
TENANT PROTECTION PLAN IN CONJUNCTION WITH NB # 320376972. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
CLASS - 2
SHORTEN GOVERNOR ROPE. CLEAN GOVERNOR ROPE FOR PROPER INSPECTION. ADJUST ZONE LOCK RESTRICTOR TO ENSURE PROPER OPERAT...
-
CLASS - 2
FAILURE TO FILE ACCEPTABLE CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES RE...
2023
-
Alteration Type III
EMERGENCY SHORING JOB REQUIRED BY DOB SEP EXCAVATION UNIT RELATED TO DOB JOB. NO.320376972 DOC 6
-
HPD violation Jul 6, 2023
Class A
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ...
-
HPD violation Jul 6, 2023
Class A
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R...
-
HPD violation Jul 6, 2023
Class A
§ 27-2101 ADM CODE FILE WITH THIS DEPARTMENT A WRITTEN DESIGNATION FOR CHANGE IN MANAGING AGENT OF BUILDING.
-
HPD violation Jul 6, 2023
Class A
§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CERAMIC TILES SURFACE ,CAULKING AND GROUTS JOIN...
-
HPD violation Jul 5, 2023
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
DOB violation Feb 3, 2023
FISPHAZ-HAZARDOUS CONDITION (FACADE) FACADE REQUIRED
CYCLE 9A UNSAFE REPORT FILED
2022
-
CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA...
-
CLASS - 1
FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES,SUCH AS SHED NETTING,ETC,WHERE REQD TO PROTECT&SECURE PUBLIC SAFETY FROM ...
-
DOB violation Oct 7, 2022
C-CONSTRUCTION OTHER OPTIONAL
EMERGENCY WORK ORDER DUE TO SPALLED AND CRACKED CONCRETE/BRICKS AT MULTIPLE LOCATIONS ON EXP1(EAST ELEV), EXP2(SOUTH ...
-
CLASS - 2
ELECTRICAL WORK W/O PERMIT WORK W/O PERMIT FOR COMPLETION OF APP B409522&B385516 FOR FIXTURES,SWITCHES,OUTLETS,BRANCH...
-
DOB violation Feb 22, 2022
FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
2021
-
Alteration Type III
INSTALLATION OF PIPE SCAFFOLD AND NEEDLE BEAMS AS PER PLANS. ALL WORK SHALL BE ACCORDING TO CHAPTER #33 OF THE 2008 N...
-
Alteration Type III
INSTALLATION OF HORIZONTAL SAFETY NETTING AS PER PLANS. ALL WORK SHALL BE ACCORDING TO CHAPTER #33 OF THE 2008 NYC BU...
-
DOB violation Dec 1, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
Alteration Type II
INSTALLATION OF KITCHEN FIRE SUPPRESSION SYSTEM. NO CHANGE IN USE,EGRESS OR OCCUPANCY. WORK IS BEING DONE IN A NEW BU...
-
DOB violation Apr 29, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
2020
-
DOB violation Sep 2, 2020
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2018
2012
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records