| Dec 1, 2022 | 39509781R | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION ,OBSERVED 6 STORY NEW BUILDING. SUPERINTENDENT WAS IN THE SITE. I WALKED INSIDE THE BUILDIN... | $1,250 | $0 | May 8, 2023 |
| Nov 22, 2022 | 39509407R | RESOLVE | CLASS - 1 | OBSERVED 2 WORKERS UPON A PUMP JACK SCAFFOLD PARTICIPATING IN CONSTRUCTION WORK. UPON FURTHER REVIEW, PARTIAL STOP WO... | $0 | $0 | Jul 13, 2023 |
| Nov 22, 2022 | 39509404L | RESOLVE | CLASS - 2 | OBSERVED 2 WORKERS UPON A PUMP JACK SCAFFOLD PARTICIPATING IN CONSTRUCTION WORK. PHONE CALLS WERE MADE TO G.C., OWNER... | $1,250 | $0 | Mar 1, 2023 |
| Feb 3, 2022 | 35641124J | RESOLVE | CLASS - 2 | WORK NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AT THE TIME OF INSPECTION I OBSERVED: TIE BACK FOR LIFELINE & TIE... | $625 | $0 | Oct 7, 2022 |
| Feb 3, 2022 | 35641123H | RESOLVE | CLASS - 2 | FAILURE TO OBTAIN TEMPORARY CONSTRUCTION PERMIT. AT THE TIME OF INSPECTION PROPOSED 6 FL STY NEW BLDG I OBSERVED: PUM... | $1,250 | $0 | Oct 7, 2022 |
| Feb 3, 2022 | 35641526M | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED AT THE TIME OF INSPECTION NB 6 STY. I OBSERVED FACADE WORK NOT COMPLE... | $2,400 | $0 | Oct 7, 2022 |
| Feb 3, 2022 | 35641525K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENT REQUIRED BY BC 33(ELEVATOR PLATFORM DD 3301.6.1). AT THE TIME OF INSPECT... | $625 | $0 | Oct 7, 2022 |
| Nov 16, 2020 | 35509173H | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET SPECIFICATION #3307.6.4.8(1) NOTE AT THE TIME OF MY INSEPCTION I OBSERVED A SIDEW... | $2,400 | $0 | Mar 31, 2021 |
| Sep 29, 2020 | 39029446R | RESOLVE | CLASS - 2 | THE EXTERIOR WALLS ON EXPOSURE #1,#2,#3 & #4 FROM 1ST. TO 6TH. FLOOR WERE INSTALLED WITHOUT R-11.4CI RIGID INSULATION... | $1,250 | $0 | Feb 3, 2021 |
| Sep 15, 2020 | 35499152M | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION NOTE AT TIME OF MY INSPECTION OF A 6 STORY NEW BUILDING UNDER ... | $2,400 | $0 | Mar 11, 2021 |
| Sep 1, 2020 | 39027882Y | RESOLVE | CLASS - 2 | AT TIME OF ENERGY CODE COMPLIANCE INSPECTION. I OBSERVED THAT THERE WERE NO COMPLETE SETS OF DOB APPROVED PLAN AT SIT... | $1,563 | $0 | Jan 6, 2021 |
| Mar 4, 2020 | 35408125K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED PLANS.NB#321040565 ON AN ENERGY COMPLIANCEINSPECTION I OBSERVED CONSTRUCTION WORK WITHOUT... | $625 | $0 | Jul 8, 2020 |
| Feb 26, 2020 | 35472189X | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTOIN DOES NOT MEET CODE SPECIFICATION#3307.6.4.8.NOTEAT THE TIME OF 6:15PM OF MY INSPECTION,I OBSERV... | $2,400 | $0 | Jul 1, 2020 |
| Feb 4, 2020 | 35471733X | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION#3307.6.4.8.NOTEAT THE TIME OF MY INSPECTION,I OBSERVED SIDEWAL... | $2,400 | $0 | Jun 10, 2020 |
| Oct 2, 2019 | 35455994Y | RESOLVE | CLASS - 2 | PERMIT EXPIRED FOR TEMPORARY CONSTRUCTION EQUIPMENT SITE(HEAVY DUTY SIDEWALK SHED). AT TIME OF INSPECTION ON A 6 STOR... | $0 | $0 | Feb 6, 2020 |
| Oct 2, 2019 | 35455992K | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTIONS REQUIREMENTS. NOTED AT TIME OF INSPECTION ON A 6 STORY NB(PROPOSE... | $0 | $0 | Feb 6, 2020 |
| Oct 2, 2019 | 35460478Y | RESOLVE | CLASS - 2 | PROHBITED OUTDOOR ADVERTISING COMPANY SIGN ON FENCE.NOTED:@TIME OF INSP ON A 6 STORY NB.I OBSERVED NO ONGOING CONST W... | $1,250 | $0 | Feb 26, 2020 |
| Jul 1, 2019 | 35436931N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED. AT THE TIME OF INSPECTION OF A NEW BLDG UNDER CONSTRUCTION. 5 STY IN... | $2,400 | $0 | Oct 28, 2019 |
| May 30, 2019 | 35431799M | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED OR NOT MAINTAINED PURSUANT TO SUBSECTION. NOTED: AT TIME OF INSPECTION AT AN ACTIVE JO... | $800 | $0 | Sep 16, 2019 |
| May 30, 2019 | 35432075L | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXP PERMIT. NOTED: AT TIME OFINSPECTION OF 6 STY BLDG,UPON REVIEWING BIS/DOB... | $625 | $0 | Sep 19, 2019 |
| Dec 19, 2018 | 35367253R | RESOLVE | CLASS - 1 | 28-207.2.2 WORK UNLAWFUL CONTRARY TO FSWO AT TIME OF INSPECTION OF A NEW BLDG UNDER CONSTRUCTION NO WORK IN PROGRESS ... | $0 | $0 | Mar 25, 2019 |
| Dec 19, 2018 | 35367254Z | RESOLVE | CLASS - 1 | 28207.2.2 WORK UNLAWFUL CONTRARY TO FSWO AT TIME OF MY INSPECTION OF A NEW BUIDLING UNDER CONSTRUCTION NO WORK ON EGR... | $2,500 | $0 | Jul 1, 2019 |
| May 31, 2018 | 35314091Y | RESOLVE | CLASS - 1 | THE RESPONDENT FAILED TO PROVIDE THE REQUIRED NUMBER OF BORINGS AS REQUIRED IN BC 1802.4L.1 BC 1802.4.1 MANDATES "TWO... | $2,500 | $2,500 | Oct 15, 2018 |
| May 31, 2018 | 35296446H | RESOLVE | CLASS - 1 | BC 1704.20.6 THE RESPONDENT,SPECIAL INSPECTOR,FAILED TO MEET THE REQS OF BC 1704.20.6.BC 1704.20.6 MANDATED "PRIOR TO... | $2,530 | $0 | Aug 13, 2018 |
| May 31, 2018 | 35296447J | RESOLVE | CLASS - 1 | THE RESPONDENT PERMIT HOLDER FAILED TO MEET THE REQUIREMENTS OF BC 1704.20.6 BC 1704.20.6 MANDATES PRIOR TO COMMENCEM... | $6,250 | $0 | Aug 13, 2018 |
| May 15, 2018 | 35331193J | RESOLVE | CLASS - 1 | SUPPORTD SCAFFOLD INSTALLED W/OUT PERMIT.@TIME OF INSP ON A ACTIVE JOBSITE,OBSERVED SCAFFOLD INSTALLED @EXP#1,EXP#2 &... | $0 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331192H | RESOLVE | CLASS - 1 | SUPERINTENDENT LOGBOOK. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF 6STORY BUILDING, OBSERVED THAT NEW SUPER WAS ON ... | $625 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331379H | RESOLVE | CLASS - 1 | BC3305.2.2 FIELD CONNECTIONS (STRUCTUREL STEEL) AT TIME OF INSPECTIONON AN ACTIVE JOBSITE OF A 6 STORY BLDG, OBSEVED ... | $2,500 | $0 | Dec 4, 2018 |
| May 15, 2018 | 35331380P | RESOLVE | CLASS - 1 | WORK CONTRARY TO APPROVED PLANS. AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 6STORY BLDG, OBSERVED THAT C-JOISTS W... | $625 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331195N | RESOLVE | CLASS - 2 | BC 3307.2.1 FAILURE TO COMPLY W/DOT REGUALTIONS @TIME OF INSP ON A ACTIVE JOBSITE OF A 6 STORY BLDG,OBSERVED MATERIAL... | $250 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331196P | RESOLVE | CLASS - 1 | BC 3303.5.2 DROPPING OR THROWING PROHIBITED @TIME OF INSP ON A ACTIVE JOBSITE OF A 6 STORY BLDG OBSERVED WORKER THROW... | $625 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331198Z | RESOLVE | CLASS - 1 | STANDING WATER 3 INCHES OR MORE.@TIME OF INSP ON A ACTIVE JOBSITE OF A6 STORY BLDG,OBSERVED STANDING WATER ON ELEVATO... | $625 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331381R | RESOLVE | CLASS - 1 | BC 3314.14.4.5 DISLODGEMENT (UNATTENDED MATERIAL ON SUPPORT SCAFFOLD)AT TIME OF INSPECTION ON A ACTIVE JOBSITE OF A 6... | $0 | $0 | Nov 28, 2018 |
| May 15, 2018 | 35331197R | RESOLVE | CLASS - 1 | BC 3307.5 FLAGS/FLAGGER (NO CERT) @TIME OF INSP ON A ACTIVE JOBSITE OF6 STORY BLDG,OBSERVED FORM LIFT OPS ON THE STRE... | $625 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331375K | RESOLVE | CLASS - 1 | BC 3301.2 DESIGN DRAWINGS (SUPPORTED SCAFFOLD) @TIME OF INSP ON A ACTIVE JOBSITE OF A 6 STORY BLDG, OBSERVED A SUPPOR... | $1,250 | $0 | Nov 30, 2018 |
| May 15, 2018 | 35331194L | RESOLVE | CLASS - 1 | ROOR PROTECTION/OVERHEAD PROTECTION @TIME OF INSP ON A ACTIVE JOBSITE OF A 6 STORY BLDG OBSERVED FIRE ESCAPR @EXP#2 P... | $5,000 | $0 | Dec 4, 2018 |
| May 15, 2018 | 35331199K | RESOLVE | CLASS - 1 | WORK CONTRARY TO A STOP WORK ORDER @TIME OF INSP ON A ACTIVE JOBSITE OF A (6) STORY BLDG, OBSERVED WORK BEING DONE ON... | $5,000 | $0 | Dec 4, 2018 |
| Apr 3, 2018 | 35318274P | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE &/OR HAVE CONSTRUCTION SUPERINTENDENT PRESENT AT SITE WHEN REQUIRED. AT TIME OF INSPECTION OBSER... | $2,500 | $0 | Mar 18, 2019 |
| Mar 1, 2018 | 35327235R | RESOLVE | CLASS - 1 | BC 3303.4.7 NO DOB PERMIT FOR MATERIAL(STORAGE)ON STREET @TIME OF INSPOF A 6 STORY BLDG FOR AN INCIDENT DURING MY INS... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327241N | RESOLVE | CLASS - 1 | BC 3307.3 NO PEDESTRIAN PROTECTION AROUND STORED MATERIAL ON STREET @TIME OF INSP OF A 6 STORY BLDG FOR AN INCIDENT D... | $0 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327239Y | RESOLVE | CLASS - 1 | BC 3303.4.5 IMPROPER MATERIAL STORAGE @CONST SITE @TIME OF INSO OF A 6STORY BLDG FOR AN INCIDENT DURING MY INSP I OBS... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327243R | RESOLVE | CLASS - 1 | BC3314.2 SUPPORTED SCAFFOLD NOT PROPERLY BUILT (BASE PLATES) AT TIME OF INSPECTION OF A 6STY BLDG FOR AN INCIDENT DUR... | $1,250 | $0 | Dec 3, 2018 |
| Mar 1, 2018 | 35327228Z | RESOLVE | CLASS - 1 | BC3307.2.3 OVERHEAD PROTECTION FOR WALKWAY WITHIN SITE AT TIME OF INSPECTION FOR AN INCIDENT I OBSERVED THAT OVERHEAD... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327242P | RESOLVE | CLASS - 1 | HOUSEKEEPING. AT TIME OF INSPECTION FOR A 6 STORY BUILDING FOR AN INCIDENT DURING MY INSPECTION I OBSERVED EXCESSIVE ... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327240L | RESOLVE | CLASS - 1 | BC3301.7 DESIGN DRAWINGS. AT TIME OF INSPECTION ON A 6 STORY BLDG FORAN INCIDENT DURING MY INSPECTION I OBSERVED PLAT... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327237K | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD PUBLIC & PROPERTY @TIME OF INSP ON A 6 STY BLDG FOR AN INCIDENT DURING MY INSP I OBSERVED @6TH F... | $2,500 | $0 | Dec 4, 2018 |
| Mar 1, 2018 | 35327236Z | RESOLVE | CLASS - 1 | BC 3309.1 INADEQUATE ROOF PROTECTION FOR ADJOINING BLDG @TIME OF INSP FOR A 6 STORY BLDG FOR AN INCIDENT DURING MY IN... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327233N | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/ MANUFACTURERS SPECIFICATIONS. AT TIME OF INSPECTION ON A 6STORY BLDG FOR AN INCIDENT DURING MY I... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327226P | RESOLVE | CLASS - 1 | 1RCNY330102 INADEQUATE LOGBOOK. AT TIME OF INSPECTION FOR AN INCIDENTI ASKED SITE SUPER TO LOOK AT HI SLOGBOOK. AT TH... | $400 | $0 | Nov 30, 2018 |
| Mar 1, 2018 | 35327227R | RESOLVE | CLASS - 1 | SUPER FAILED TO PERFORM HIS/HER DUTIES. AT TIME OF INSPECTION FOR AN INCIDENT UPON ARRIVAL OF SITE I ASKED JOB SUPER ... | $10,000 | $0 | Nov 30, 2018 |