378 South 3 Street, Brooklyn • Block 02438 • Lot 0013
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 10, 2018 | 35331761Z | RESOLVE | CLASS - 1 | TAMPERED W/REMOVED OR DEFECTED A WRITTEN STOP WORK ORDER. AT THE TIME OF INSPECTION AT MAIN FRONT ENTRANCE DOOR,SWO P... | $0 | $0 | Aug 13, 2018 |
| Jun 10, 2018 | 35339585P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35236609Z ISSUED ON 11-20-17 & TO FILE A C OF C PURSUAN... | $625 | $625 | Aug 13, 2018 |
| Apr 30, 2018 | 35337541Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35236609Z ISSUED ON 11/20/17 AND TO FI... | $0 | $0 | Aug 20, 2018 |
| Mar 11, 2018 | 35317409Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35236609Z ISSUED ON 11/20/17 & TO FILE A C OF C PURSUAN... | $1,280 | $0 | May 7, 2018 |
| Jan 30, 2018 | 35282569K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35294396J ISSUED ON 12/06/17 & TO FILE A C OF C PURSUAN... | $0 | $0 | Mar 26, 2018 |
| Jan 17, 2018 | 35282557N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35236609Z ISSUED ON 11/20/17 & TO FILE A C OF C PURSUAN... | $800 | $800 | Jan 7, 2019 |
| Dec 6, 2017 | 35294396J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUAR PUBLIC & PROPERTY AFFECTED BY CONST OPS.(STATISTIC) UNEVEN,ERECTING A TRIPPING HAZARD "Q" DECKING... | $0 | $0 | Jan 29, 2018 |
| Nov 20, 2017 | 35236609Z | RESOLVE | CLASS - 1 | 28-207.2.2 FAILURE TO COMPLY WITH A COMMISSIONER'S ORDER TO STOP ALL WORK. NOTED: STOP WORK ORDER ISSUED ON 08/24/17 ... | $1,600 | $0 | Apr 9, 2018 |
| Nov 1, 2017 | 35236608R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: JOB# 321210006 EXP 9/9/17. STAIR T... | $10,000 | $10,000 | Jan 7, 2019 |
| Aug 24, 2017 | 35236818P | RESOLVE | CLASS - 2 | FAILURE OF PERMIT HOLDER TO PROVIDE INSPECTION ACCESS TO AND/OR EXPOSE ONGOING CONSTRUCTION OR WORK ON AN ACTIVE AND ... | $1,200 | $0 | Oct 30, 2017 |
| Jun 2, 2017 | 35246698Z | RESOLVE | CLASS - 2 | 1RCNY3301-02(D) CONSTRUCTION SUPERINTENDENT FAILS TO MAINTAIN AND/OR MAKE JOB SITE LOGS AVAILABLE.AT THE TIME OF THE ... | $0 | $0 | Jul 17, 2017 |
| Jun 2, 2017 | 35246699K | RESOLVE | CLASS - 2 | FAILURE TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN ALL DIRECTIONSDURING EXCAVATION-RELATED ACTIVITY THAT MAY ADV... | $0 | $0 | Jul 17, 2017 |
| Jun 2, 2017 | 35246797Y | RESOLVE | CLASS - 2 | 1RCNY 101-06:SPECIAL INSPECTOR MUST BE REGISTERED/LICENSED TO PERFORM SPECIAL INSPECTIONS W/DOB.AT THE TIME OF INSPEC... | $800 | $0 | Oct 25, 2017 |
| Jun 2, 2017 | 35246776P | RESOLVE | CLASS - 2 | BC1RCNY 101-06(C)(1)SPECIAL INSPECTOR MUST BE LICENSED TO PERFORM SPECIAL INSPECTIONS WITH DOB.AT TIME OF INSPECTION ... | $2,000 | $0 | Jul 17, 2017 |
| Jun 2, 2017 | 35246775N | RESOLVE | CLASS - 2 | BC1704.1.1 FAILURE TO FILE A SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUANCE AND PRIOR TO STA... | $2,000 | $0 | Jul 17, 2017 |
| Dec 12, 2016 | 35218839P | RESOLVE | CLASS - 1 | 3309.6 FAILURE TO MAINTAIN ADJOINING STRUCTURES OR MOVEMENT IN ALL DIRECTIONS DURING EXCAVATION-RELATED ACTIVITY THAT... | $4,000 | $0 | Jan 30, 2017 |
| Dec 12, 2016 | 35218837L | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ACCEPTED/APPROVED PLANS AT JOB SITE AT TIME OF INSPECTION.NOTED:AT TIME OF INSPECTION CONTRACTOR I... | $0 | $0 | Jan 30, 2017 |
| Dec 12, 2016 | 35218838N | RESOLVE | CLASS - 1 | 3301.2 FAILURE TO PROVIDE 3 FOOT 6 INCH GUARDRAIL ON EQUIPMENT AROUND ALL FLOOR AND PERIMETER OPENING.NOTED:AT TIME O... | $4,000 | $0 | Jan 30, 2017 |
| Dec 12, 2016 | 35218840M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTED:AT TIME OF INSPECTION THE FOL... | $12,500 | $0 | Jan 30, 2017 |
| Apr 6, 2011 | 34906055J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE A COFC W/THE DOB RESPONDET FAILED TO COMPLY W/THE COMM'S ORDER TP CORREC... | $2,000 | -$2,000 | May 23, 2011 |
| Feb 25, 2011 | 34894040L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN. NOTED: EXTERIOR FRONT FACADE CRACKS, & DISPLACEMENT @ 3RD FLR LEVEL, LOOSE BRICKS, ALSO VISIBLE ... | $5,000 | -$5,000 | Apr 11, 2011 |
| Dec 16, 2010 | 34893137N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN. NOTED: STRUCTURE'S EXTERIOR BRICK WALL IN DISREPAIR,WITH LOOSE,DISPLACED & CRACKS OBSERVED IN FA... | $2,500 | -$2,500 | Feb 7, 2011 |
| Sep 29, 2010 | 34862224J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALL. NOTED: CRACKED & DISPLACED BRICK WORK AROUND CORRODED LINTELS & BRICK SHELVES AT E... | $2,500 | -$2,500 | Dec 6, 2010 |
| Oct 10, 2009 | 34810330Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES.NOTE:THE FRONT PARAPET WALL IS BULGING @ THE 3RD FLR. WINDOW LINTELS L... | $2,500 | -$2,500 | Mar 1, 2010 |
| May 27, 2009 | 34775836P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL(S) AND/OR APPURTENANCES. NOTED: AT FRONTOF PREMISES AT ROOF LEVEL, PARAPET WALL HAS AN ... | $1,000 | $0 | Jul 20, 2009 |