Maintenance code violations
196 Huron Street, Brooklyn • Block 02533 • Lot 0021
863 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Feb 5, 2020 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1R | Mar 11, 2020 |
| Feb 5, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE PIPE AT SINK IN THE KITCHEN LOCATED AT APT 1R, 1st... | 1R | Mar 11, 2020 |
| Feb 5, 2020 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURES AT CEILING IN THE KITCHEN LOCATED AT APT 1R... | 1R | Mar 11, 2020 |
| Feb 3, 2020 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCAT... | IR | Feb 24, 2020 |
| Feb 3, 2020 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL IN THE 2nd ROOM FRO... | IR | Feb 24, 2020 |
| Feb 3, 2020 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH AND WEST WALLS IN THE 1... | IR | Feb 24, 2020 |
| — | I | VIOLATION DISMISSED | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESU... | — | — |
| Jan 16, 2020 | B | VIOLATION DISMISSED | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRIC LIGHT AT CEILING... | 1R | Feb 20, 2020 |
| Jan 16, 2020 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 2L | Feb 13, 2020 |
| Jan 16, 2020 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1R, 1st STORY, 1... | 1R | Feb 20, 2020 |
| Jan 16, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST, NORTH AND EAST WALLS, A... | 1R | Apr 20, 2020 |
| Jan 16, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRIC OUTLET AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1... | 1R | Feb 20, 2020 |
| Jan 16, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING, APROX. 7 AQ FT IN TH... | 1R | Apr 20, 2020 |
| Jan 16, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE MECHANICAL VENTILATION COVER AT CEILING IN THE BATHROOM LOCATED AT APT 1... | 1R | Apr 20, 2020 |
| Jan 16, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 1R, 1st... | 1R | Feb 20, 2020 |
| Jan 16, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE K... | 1R | Feb 20, 2020 |
| Jan 15, 2020 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR | — | Jan 23, 2020 |
| Jan 15, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL, APROX. 7 SQ. FT. ... | 2L | Apr 19, 2020 |
| Jan 15, 2020 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd ... | 2L | Feb 5, 2020 |
| Jan 15, 2020 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STO... | 2L | Feb 5, 2020 |
| Jan 14, 2020 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, ... | 2L | Jan 10, 2020 |
| Jan 8, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOOSE SINK CABINET IN THE KITCHEN LOCATED AT APT 1L, 1st S... | 1L | Feb 12, 2020 |
| Jan 6, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 5 SQ,FT EAST WALL IN THE KITCHEN... | 1L | Apr 10, 2020 |
| Jan 6, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 5 SQ,FT SOUTH WALL IN THE BATHRO... | 1L | Apr 10, 2020 |
| Jan 3, 2020 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st ... | 1L | Jan 24, 2020 |
| Jan 3, 2020 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 1L | Jan 31, 2020 |
| Jan 3, 2020 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING INSIDE T... | 1L | Apr 7, 2020 |
| Jan 3, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT SOUTH WINDOW LOWER SASH IN THE KITCHEN ... | 1L | Feb 7, 2020 |
| Jan 3, 2020 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST,WEST AND SOUTH WALLS APP... | 1L | Feb 7, 2020 |
| Dec 30, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX..10 SQ.FT IN T... | 1R | Jan 20, 2020 |
| Dec 30, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... NORTH WALL AT WINDOW, APPROX. 10... | 1R | Jan 20, 2020 |
| Dec 30, 2019 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... NORTH WALL 2 SQ FT, WEST WALL 2 ... | 1R | Jan 20, 2020 |
| Dec 23, 2019 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 8 SQ.FT AT CEILING AND 2 SQ.FT A... | 1R | Jan 27, 2020 |
| Dec 23, 2019 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1R | Jan 27, 2020 |
| Dec 23, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 1R | Jan 27, 2020 |
| Dec 19, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL (APPROX. 3 SQ. FT.)... | 1R | Mar 23, 2020 |
| Dec 19, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX. 1 SQ. FT.) I... | 1R | Mar 23, 2020 |
| Dec 19, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE SURFACE ON BA... | 1R | Jan 23, 2020 |
| Dec 19, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL (APPROX. 2 SQ. FT.)... | 1R | Mar 23, 2020 |
| Dec 19, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE KITCHEN LOCATED AT ... | 1R | Jan 23, 2020 |
| Dec 19, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL (APPROX. 2 SQ. FT.... | 1R | Mar 23, 2020 |
| Dec 19, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL LIGHTING TO THE FIXTURE AT CEILING IN THE KITCHEN LOCATED ... | 1R | Jan 23, 2020 |
| Dec 19, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL (APPROX. 1 SQ FT) I... | 1R | Mar 23, 2020 |
| Dec 12, 2019 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES ,,,,,, IN THE BATHROOM LOCATED AT APT 2L, 2n... | 2L | Jan 16, 2020 |
| Dec 12, 2019 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 2L | Mar 16, 2020 |
| Dec 12, 2019 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STO... | 2L | Jan 2, 2020 |
| Dec 12, 2019 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd ... | 2L | Jan 2, 2020 |
| Dec 12, 2019 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NO... | 2L | Jan 16, 2020 |
| Dec 12, 2019 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES ,,,,,,,,,, IN THE BATHROOM LOCATED AT APT 2... | 2L | Jan 16, 2020 |
| Dec 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN TH... | 2L | Jan 16, 2020 |