Maintenance code violations
196 Huron Street, Brooklyn • Block 02533 • Lot 0021
863 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Mar 31, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 2L,... | 2L | Jul 4, 2021 |
| Mar 5, 2021 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL CLOSET IN THE 2nd ... | 1R | Apr 9, 2021 |
| Mar 5, 2021 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL IN THE 3rd ROOM FRO... | 1R | Apr 9, 2021 |
| Feb 16, 2021 | B | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT STOVE IN THE KITCHEN LOCATED AT APT 1R, 1st S... | 1R | Mar 23, 2021 |
| Jan 29, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILED FLOOR IN THE KITCHEN L... | 1L | Feb 4, 2021 |
| Jan 29, 2021 | A | VIOLATION CLOSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL IN THE BATHROOM LOCATE... | 1L | May 4, 2021 |
| Jan 29, 2021 | C | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OF ABOUT 30 SQ FT AT THE CEILING... | 1R | Feb 24, 2021 |
| Jan 29, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC AIR VENT IN THE BATHROOM LOCATED AT APT 1R, 1st S... | 1R | Mar 5, 2021 |
| Jan 29, 2021 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM... | 1R | Feb 4, 2021 |
| Jan 29, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 1R | Feb 4, 2021 |
| Jan 26, 2021 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AROUND DOOR FRAME IN THE BATHROO... | 1R | Mar 2, 2021 |
| Jan 26, 2021 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL NEAR BASEBORD IN TH... | 1R | Mar 2, 2021 |
| Jan 26, 2021 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 1R | Feb 21, 2021 |
| Jan 26, 2021 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... INSIDE UPPER WALL CABINET AT WES... | 1R | Mar 2, 2021 |
| Jan 25, 2021 | C | VIOLATION WILL BE REINSPECTED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2L | Feb 20, 2021 |
| Jan 25, 2021 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd ... | 2L | Feb 20, 2021 |
| Jan 25, 2021 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROX. 5 SQ FT) AT WEST WALL I... | 1R | Apr 30, 2021 |
| Jan 25, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOC... | 2L | Mar 1, 2021 |
| Jan 25, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT UPPER SASH AT 2ND WINDOW FROM WEST AT ... | 2L | Mar 1, 2021 |
| Dec 30, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN ... | 1R | Feb 3, 2021 |
| Dec 30, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT THE DOOR IN THE BATHROOM LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | 1R | Apr 4, 2021 |
| Dec 30, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILNG ,EAST WA... | 1R | Jan 5, 2021 |
| Dec 30, 2020 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THE CEILING,EAST WALL AND WEST... | 1R | Jan 5, 2021 |
| Dec 29, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1L, 1st STORY | 1L | Feb 2, 2021 |
| Dec 29, 2020 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st ... | 1L | Jan 24, 2021 |
| Dec 7, 2020 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM L... | 1R | Mar 12, 2021 |
| Dec 7, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT 2ND WINDOW FROM WEST AT ... | 1R | Jan 11, 2021 |
| Dec 7, 2020 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1R | Jan 11, 2021 |
| Dec 7, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT 1ST WINDOW FROM WEST AT ... | 1R | Jan 11, 2021 |
| Dec 7, 2020 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2L | Jan 2, 2021 |
| Dec 7, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN L... | 1L | Jan 11, 2021 |
| Nov 23, 2020 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1s... | 1R | Nov 20, 2020 |
| Nov 20, 2020 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM .. LOCKED DOOR AT BASEMENT | — | Nov 26, 2020 |
| Nov 20, 2020 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE WEST WALL AT THE SOUTH CL... | 1R | Dec 25, 2020 |
| Nov 20, 2020 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT THE WASTE LINE UNDER BASIN SINK IN THE KITCHEN LOCATE... | 1R | Nov 26, 2020 |
| Nov 20, 2020 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Nov 26, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL IN THE KITCHEN ... | 1R | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLOOR OF SINK BASE CABINET IN THE KI... | 1R | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WOOD SUBFLOOR AT AT... | 1L | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 1R, ... | 1R | Dec 24, 2020 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2L | Dec 15, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR BUZZER AND INTRCOM SYSTEM IN THE ENTIRE APARTMENT LOC... | 2L | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY,... | 2L | Dec 24, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WINDOW FRAME AT SOUTH WALL IN... | 1L | Feb 22, 2021 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR | — | Nov 25, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 1L, 1st ... | 1L | Dec 24, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL... | 2L | Feb 22, 2021 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE VENT FAN AT CEILING IN THE BATHROOM LOCATED AT APT 1R, 1st... | 1R | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES LOW WATER PRESSURE IN THE BATHROOM LOCATED A... | 1R | Dec 24, 2020 |
| Nov 19, 2020 | C | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 1R, 1st... | 1R | Nov 25, 2020 |