210 Huron Street, Brooklyn
Brooklyn • Block 02533 • Lot 0028 • Zip: 11222
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Union Square 30 min 8 walking, 22 riding
- Grand Central 31 min 8 walking, 23 riding
- Times Square 34 min 8 walking, 26 riding
- Downtown Brooklyn 34 min 8 walking, 26 riding
- Penn Station 39 min 8 walking, 31 riding
- Fulton Street 39 min 8 walking, 31 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Activity
Sales, filings, permits and violations from every dataset, in one order.
2017
-
HPD violation Nov 24, 2017
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2015
-
DOB violation Oct 1, 2015
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
2014
-
DOB violation Jan 15, 2014
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2013
-
CLASS - 1
NON CURRENT CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED. SIDEWALK SHED IS METAL AND COULD BE ENERGIZED. R...
-
CLASS - 2
FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER GFCI PROTECTION ASREQUIRED. NO GFCI PROVIDED FOR SIDEWALK SHED. R...
-
CLASS - 2
PROHIBITED USE OF EMT. ELECTRICAL METALLIC TUBING USED FOR OUTDOOR SHED. RMDY: COMPLY WITH EC CODE.
-
CLASS - 1
SEC. BC 3314.5.5. SUPPORTED SCAFFOLD DOES NOT MEET BLDG CODE STANDARDS. NOTED: AT TIME OF INSPECTION PLANKING ON SUPP...
-
CLASS - 2
SIDEWALK SHED DOES NOT MEET BLDG CODE SPECIFICATIONS. NOTED: AT TIME OF INSPECTION SIDEWALK SHED ERECTED ON EXPOSURE ...
-
CLASS - 1
SEC. BC 3314.8. SUPPORTED SCAFFOLD DOES NOT MEET BLDG CODE STANDARDS. NOTED: @ TIME OF INSPECTION SUPPORTED SCAFFOLD ...
-
Alteration Type III
INSTALL SIDEWALK SHED, AS PER PLAN NO CHANGE USE; EGRESS AND OCCUPANCY
2012
1997
-
DOB violation Sep 16, 1997
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
1994
-
DOB violation Jul 25, 1994
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records