| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 8, 2025 | 37035002Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $0 | $0 | Sep 8, 2025 |
| Nov 19, 2021 | 39051434K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED EXTERIOR BALCONY AND METAL PLANTERS INSTATE OF DISREPAIR CONDITIONS WITH ROTTED & MISS... | $0 | $0 | Mar 23, 2022 |
| Dec 28, 2016 | 35217463L | RESOLVE | CLASS - 2 | 3301.7 DOCUMENTS.REQUESTED DRAWINGS INSPECTION REPARTS LOGS AND CHECKLISTS FROM SUST OF CONSTRUCTION SITE REPRESENTAT... | $400 | $0 | Feb 13, 2017 |
| Dec 13, 2016 | 35200168H | RESOLVE | CLASS - 2 | 3314.4.3.5 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD.NOTE AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD IN... | $0 | $0 | Jan 30, 2017 |
| Dec 13, 2016 | 35200166Y | RESOLVE | CLASS - 1 | PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD. NOTE AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD IN PLACE WIT... | $1,630 | $0 | Jan 30, 2017 |
| Dec 13, 2016 | 35200165M | RESOLVE | CLASS - 1 | PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD. NOTE AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD IN PLACE NOT... | $1,600 | $0 | Feb 22, 2017 |
| Dec 13, 2016 | 35200167X | RESOLVE | CLASS - 1 | 3314.5.5 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD. NOTE AT TIMEOF INSPECTION I OBSERVED SUPPORTED SCAFFOLD IN P... | $1,600 | $0 | Feb 15, 2017 |
| Dec 13, 2016 | 35200169J | RESOLVE | CLASS - 1 | 3314.8.2 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD. NOTE AT TIMEOF INSPECTION I OBSERVED SUPPORTED SCAFFOLD IN P... | $1,600 | $0 | Feb 22, 2017 |
| Dec 7, 2016 | 35206763J | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED NOTIFICATION PRIOR TO THE COMMENCEMENT OF DEMOLITION. NOTED: A CHECK OF DEPT RECORDS @ TI... | $1,200 | $0 | Jun 23, 2017 |
| Dec 7, 2016 | 35206762H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED NOTIFICATION PRIOR TO THE COMMENCEMENT OF DEMOLITION. NOTED: A CHECK OF DEPT RECORDS @ TI... | $1,200 | $0 | Jun 21, 2017 |
| Jul 20, 2016 | 35196522M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION. AT TIME OF INSPECTION NOTICE 2 WORKER... | $10,000 | $0 | Sep 15, 2016 |
| Jul 20, 2016 | 35196523Y | RESOLVE | CLASS - 1 | SEC. 3308.3 VERTICAL SAFETY NETTING NOT PER CODE. AT TIME OF COMPLAINTINSPECTION NOTICED VERTICAL SAFETY NETTING IS D... | $400 | $0 | Nov 14, 2016 |
| Jul 20, 2016 | 35196519L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. AT TIME OF COMPLAINT INSPECTION FOR ... | $10,000 | $0 | Nov 17, 2016 |
| Jul 20, 2016 | 35196520Z | RESOLVE | CLASS - 1 | SEC. 3309.10 NO ADEQUATE PROTECTION FOR ROOF,SKY LIGHT NO PROTECTION FOR CHIMNEY. AT TIME OF COMPLAINT INSPECTION NOT... | $1,600 | $0 | Nov 7, 2016 |
| Jul 20, 2016 | 35196521K | RESOLVE | CLASS - 1 | SEC. 3301.2 OVERHEAD PROTECTION. AT TIME OF COMPLAINT INSPECTION NOTICED NO OVERHEAD PROTECTION PROVIDED FOR THE INGR... | $0 | $0 | Sep 12, 2016 |
| Jun 29, 2016 | 35178571J | RESOLVE | CLASS - 1 | SEC3. 3303.11 STAIRS DURING CONSTRUCTION OR DEMOLITION AT TIME OF INSPECTION OBSERVED,ACTIVE JOB SITE. THE STAIRCASES... | $400 | $0 | Nov 7, 2016 |
| Apr 12, 2016 | 35178783L | RESOLVE | CLASS - 1 | 3304.7 FAILURE TO PROVIDE SAFE ACCSESS/EGRESS. AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. EXCAVATION/FOUNDATION ... | $1,600 | $0 | Jun 7, 2016 |
| Apr 12, 2016 | 35178784N | RESOLVE | CLASS - 1 | FAILURE TO PROTECT THE SIDES OF EXCAVATION. AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE WORKERS ARE SETTING REBAR ... | $2,400 | $0 | Jun 6, 2016 |
| Dec 4, 2015 | 35162020R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN.NOTED:ROOF SHEETING ROTTED.COLLAPSED INTO THE HOUSE-COMBUSTIBLE MATERIAL.ALSO PARAPET WALL @EXP#3... | $5,000 | $0 | Jan 25, 2016 |
| Aug 23, 2012 | 34997890J | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY SIGN PROHIBITED IN C2-4 DISTRICT (CONVERSE) REMEDY: REMOVE ILLEGAL SIGN. | $5,000 | $0 | May 31, 2013 |
| Aug 23, 2012 | 34997889M | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY SIGN PROHIBITED IN C2-4 DISTRICT (CONVERSE) REMEDY: REMOVE ILLEGAL SIGN. | $5,000 | $0 | May 31, 2013 |
| Aug 23, 2012 | 34997891L | RESOLVE | CLASS - 1 | PROPERTY OWNER ACTING AS OUTDOOR ADVERTISING COMPANY FAILURE TO OBTAINOAG REGISTRATION NUMBER WHILE ENGAGING IN THE O... | $0 | $0 | May 31, 2013 |
| Aug 23, 2012 | 34997888K | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY SIGN ON DISPLAY W/O A PERMIT (CONVERSE) REMEDY: REMOVE ILLEGAL SIGN. | $5,000 | $0 | May 31, 2013 |
| Aug 23, 2012 | 34997887Z | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY SIGN ON DISPLAY W/O A PERMIT. (CONVERSE) REMEDY: REMOVE ILLEGAL SIGN. | $5,000 | $0 | May 31, 2013 |
| Oct 3, 1996 | 32014260M | RESOLVE | Non-Hazardous | 36,39. BOILER DESIGN PRESSURE IS LOOSE.EXISTING SAFETY VALVE IS SELFUR125 P81 THE LATER BE REPLACED WITH ONE SEL-MAXI... | $350 | $0 | Feb 24, 1997 |
| Jun 14, 1988 | 34008105Y | RESOLVE | Unknown | WORK WITHOUT A PERMIT. WORK NOTED APPROX TWENTY FEET LONG X APPROX TEN FEET WIDE, CONCRETE BLOCK EXTENSION BEING EREC... | $250 | $0 | Oct 24, 1988 |