| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 6, 2023 | 39517462J | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION OF A 5 STORY NEW BUILDING, OBSERVED A STORAGE ZONE AT THE BUILDING EXPOSURE 1, PLASTIC BARR... | $625 | $0 | Aug 16, 2023 |
| Nov 5, 2022 | 39508791X | RESOLVE | CLASS - 2 | SAFETY MEASURES AND STANDARDS UNCAPPED REBARS AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE , I OBSERVED ABOUT A... | $0 | $0 | Mar 8, 2023 |
| Jun 1, 2022 | 35652802N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCS REQUIRED BY CH33.ATOI OF 5STYNB UNDER CONST,I OBSERVED SUPPORTED SCF@EXP1,INS... | $625 | $0 | Oct 26, 2022 |
| Jun 1, 2022 | 35652801L | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED CONST DOC &OR APPROVED AMENDMENTS.ATOIOF 5STYNB UNDER CONST,I OBSERVED SUPPORTED SCF@... | $2,500 | $0 | Jan 19, 2023 |
| Mar 22, 2022 | 39058815X | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT; NOTED: PERMIT # B00482983-L1- SF, EXPIRED ON 03-11-2022 FOR ... | $0 | $0 | Jul 27, 2022 |
| Mar 10, 2022 | 39057823L | RESOLVE | CLASS - 2 | AT ACTIVE CONSTRUCTION SITE AT BACK OF THE BUILDING STORED EXCESSIVE AMOUNT CONSTRUCTION DEBRIS (STYROFOAM). PIECES O... | $0 | $0 | Jul 13, 2022 |
| Feb 9, 2022 | 35639535L | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ON SITE DOCUMENT ACCESS AGREEMENT/LICENSE TO ENTER WITH EXP #2 ADJACENT PROPERTY 22 MONITOR STREET... | $625 | $0 | Jun 22, 2022 |
| Jan 26, 2022 | 35642327Y | RESOLVE | CLASS - 1 | SEC. BC 3301.1.2 FAILURE TO COMPLY W/NYC FIRE CODE-GENERAL NO C OF F HOLDER ON-SITE(PORTABLE FUEL SPACE HEATERS). NOT... | $2,500 | $0 | Jun 8, 2022 |
| Jan 26, 2022 | 35642326M | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE EQUIPMENT & MATERIAL. NOTED: AT TIME OF MY INSPECTION OF A NEW 5 STY BLDG,CONSTRUCTION ... | $2,500 | $0 | Jun 8, 2022 |
| Jan 26, 2022 | 35642328X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ON-SITE DOCUMENTS REQUIRED BY BC CHAPTER 33-SWS LOG BOOK. NOTED: AT TIME OF MY INSPECTION... | $0 | $0 | Jun 8, 2022 |
| Jan 19, 2022 | 35639257K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATIONS.NOTE:AT THE TIME OFINSPECTION I OBSERVED 40 DOCK BARRIERS IN ROADW... | $0 | $0 | Jun 1, 2022 |
| Jan 19, 2022 | 35639256Z | RESOLVE | CLASS - 2 | BC 3303.4.2 CONTAINERS NOTE:AT THE TIME OF INSPECTION OF A 5 STORY NEWBUILDING I OBSERVED DEBRIS CONTAINER IN ROADWAY... | $0 | $0 | Jun 1, 2022 |
| Jan 6, 2022 | 35639702J | RESOLVE | CLASS - 2 | 3314.1 UNSAFE SUPPORTED PIPE SCAFFOLD.NOTE AT THE TIME OF INSPECTION AT A 5 STORY NEW BUILDING CONSTRUCTION I OBSERVE... | $0 | $0 | May 18, 2022 |
| Jan 6, 2022 | 35639703L | RESOLVE | CLASS - 2 | 3301.2 FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES.NOTE AT THE TIME OF INSPECTION,I OBSERVED THE ROOF... | $0 | $0 | May 18, 2022 |
| Jan 6, 2022 | 35639704N | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.NOTE AT THE TIME OF INSPECTION AT A ... | $625 | $0 | Jan 23, 2023 |
| Sep 30, 2021 | 35588083M | RESOLVE | CLASS - 2 | EQUIPMENT ONSITE IS CONTRARY TO APPROVED PLANS-SUPPORT SCAFFOLD.AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION JOBSI... | $0 | $0 | Feb 9, 2022 |
| Sep 30, 2021 | 35588082K | RESOLVE | CLASS - 1 | 3301.1.1 RESPONSIBILITY FOR SAFETY.AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION JOBSITE,I OBSERVED SEVERAL SAFETY ... | $625 | $0 | Feb 9, 2022 |
| Sep 30, 2021 | 35588084Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION... | $0 | $0 | Feb 9, 2022 |
| Jun 29, 2021 | 35575860P | RESOLVE | CLASS - 1 | BC3314.1 FAILURE TO MAINTAIN ADEQUATE SCFS.NOTE:ATOI OF 5STYNB CURRENTLY@ROOF LEVEL WORK IN PROGRESS.I OBSERVED SCF O... | $625 | $0 | Aug 15, 2022 |
| Jun 29, 2021 | 35575863K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS-NO GUARDRAILS,NO CONTROL ACCESS ZONE... | $2,500 | $0 | May 16, 2022 |
| Jun 29, 2021 | 35575862Z | RESOLVE | CLASS - 1 | HOUSEKEEPING NOTE:ATOI OF 5STYNB CURRENTLY@ROOF LEVEL,WORK IN PROGRESS.I OBSERVED LARGE AMNT OF DEBRIS,SCRAP,DIRT CRE... | $2,500 | $0 | Aug 15, 2022 |
| Jun 29, 2021 | 35575861R | RESOLVE | CLASS - 1 | 3303.4.2 DUMPSTER CONTAINER NOTE:ATOI OF5STYNB,CURRENTLY@ROOF LEVEL WORK IN PROGRESS.I OBSERVED 20CUBICYDS DUMPSTER C... | $625 | $0 | Aug 15, 2022 |
| Apr 12, 2021 | 39039200X | RESOLVE | CLASS - 2 | AT TIME OF ENERGY CODE COMPLIANCE INSPECTION. I OBSERVED THAT THERE WERE NO COMPLETE SETS OF DOB APPROVED PLANS AT SI... | $0 | $0 | Aug 18, 2021 |
| Feb 16, 2021 | 35552376L | RESOLVE | CLASS - 1 | 3307.4.7 FAILURE TO PROVIDE A BARRIER FOR STORAGE AREA. AT TIME OF INSPECTION OF A 5 STORIES NB CURRENTLY AT 4TH FL L... | $625 | $0 | Jan 7, 2022 |
| Feb 16, 2021 | 35552374H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION. AT TIME OF INSPECTION OF A 5 STORIES NB... | $5,000 | $0 | Jan 7, 2022 |
| Feb 16, 2021 | 35552377N | RESOLVE | CLASS - 1 | FAILURE TO ENSURE WORKERS RECEIVE SITE SAFETY ORIENTATION. AT TIME OF INSPECTION OF A 5 STORIES NB CURRENTLY AT 4TH F... | $2,500 | $0 | Jan 7, 2022 |
| Feb 16, 2021 | 35552375J | RESOLVE | CLASS - 1 | 3307.2.1 OBSTRUCTION OF STREET ON EXP#1. AT TIME OF INSPECTION OF A 5 STORIES NB CURRENTLY AT 4TH FL LEVEL,I OBSERVED... | $0 | $0 | Jan 7, 2022 |
| Aug 12, 2020 | 35497935J | RESOLVE | CLASS - 2 | SEC. 3307.2.1 DOT PERMIT SPECIFIES TO NOT PLACE MATERIALS OR CONTAINERWITHIN 15-0 OF FIRE HYDRANT AS PER STIPULATION ... | $625 | $0 | Feb 26, 2021 |
| Aug 12, 2020 | 35497933X | RESOLVE | CLASS - 1 | SEC. 3301.13.1 NO SITE SAFETY PLAN. AT TIME OF INSPECTION I REQUESTED TO SEE SITE SAFETY PLAN. AS PER BC 3301.7 THIS ... | $625 | $0 | Feb 26, 2021 |
| Aug 12, 2020 | 35497934H | RESOLVE | CLASS - 2 | CONSTRUCTION FENCE. AT TIME OF INSPECTION I OBSERVED NO CONSTRUCTION FENCE HAD BEEN ERECTED AT PROPERTY LINE AT REAR ... | $500 | $0 | Feb 26, 2021 |
| Aug 12, 2020 | 35497936L | RESOLVE | CLASS - 2 | SEC. 3307.6.5 SIDEWALK SHED-ON SITE DOCUMENT. AT TIME OF INSPECTION OBSERVED DRAWINGS FOR SIDEWALK SHED WAS NOT WHAT ... | $625 | $0 | Feb 26, 2021 |
| Jul 8, 2020 | 35410641J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ONGOING CONSTRUCTION ACTIVITES CONTRARY TO MAYOR'S EMERGENCY EXECUTIVE ORDERS 120 AND ... | $0 | $0 | Feb 4, 2021 |
| Jul 8, 2020 | 35410642L | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ONGOING CONSTRACTION ACTIVITIES CONTRARY TO MAYOR'S EMERGENCY EXECUTIVE ORDER'S 120 AN... | $0 | $0 | Feb 4, 2021 |
| Apr 6, 2020 | 35491834N | RESOLVE | CLASS - 2 | SEC. 3307.6.4.8 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT THE TIME OF MY INSPECTION I OBSERVE... | $2,400 | $0 | Aug 12, 2020 |
| Jan 8, 2020 | 35462982M | RESOLVE | CLASS - 2 | VIEW PANELS FENCE. AT TIME OF INSPECTION,I OBSERVED A JOBSITE FENCE 8 FEET HIGH THAT HAD NO VIEW PORTS INSTALLED IN F... | $500 | $0 | Dec 18, 2020 |
| Jan 8, 2020 | 35462983Y | RESOLVE | CLASS - 2 | SEC. 3301.9.1 PROJECT INFORMATION PANEL. AT TIME OF INSPECTION OF A JOBSITE I OBSERVED THAT THE INFORMATION PANEL WAS... | $625 | $0 | Dec 18, 2020 |
| Jan 8, 2020 | 35462984X | RESOLVE | CLASS - 1 | SEC. 3307.2.1 OBSTRUCTION OF SIDEWALK OR STREET. AT TIME OF INSPECTIONI OBSERVED SIDEWALK CLOSED OFF W/YELLOW CAUTION... | $625 | $0 | Dec 18, 2020 |
| Jul 18, 2019 | 39005805N | RESOLVE | CLASS - 3 | BUILDING APPEARS VACANT. 1. GLASS PANEL ON FRONT DOOR IS BROKEN ALLOWING UNAUTHORIZED ACCESS TO THE BUILDING; 2. AN A... | $500 | $0 | Dec 18, 2019 |