Maintenance code violations
307 Devoe Street, Brooklyn • Block 02918 • Lot 0044
205 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jan 16, 2014 | A | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND W... | 2R | Apr 21, 2014 |
| Jan 16, 2014 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2L, 2nd ... | 2L | Feb 20, 2014 |
| Jan 16, 2014 | A | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, EAST WALL,... | 2L | Apr 21, 2014 |
| Aug 22, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PORCELAIN FINISH AT BATHTUB IN THE BATHROOM LOCATED... | REAR | Sep 26, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT REAR, 3rd STORY, 1st APARTMEN... | REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT REAR, 3r... | REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT REAR, 3rd... | REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT REAR, 3rd STORY, 1st APARTMENT F... | REAR | Sep 25, 2013 |
| Aug 21, 2013 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS (TOTAL-2) AT BALUSTRADE AT PUBLIC HALL STAIRS, 2nd STORY | — | Aug 29, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCA... | REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION DRAIN PIPE UNDER WASH/BASIN IN THE BATHROOM LOCATE... | 1REAR | Sep 25, 2013 |
| Aug 21, 2013 | A | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 1REAR... | 1REAR | Nov 24, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT NORTH ONE WINDOW AND... | 1REAR | Sep 25, 2013 |
| Aug 21, 2013 | C | VIOLATION CLOSED | SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPEC... | REAR | Sep 18, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDO... | 1REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 1REAR, 1st STORY, 1st APARTME... | 1REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 1REAR, 1s... | 1REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM W... | 2R | Sep 25, 2013 |
| Aug 21, 2013 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING NAILED SHUT SCUTTLE COVER AT PUBLIC HALL, 2nd STORY | — | Aug 29, 2013 |
| Aug 21, 2013 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURF... | 1REAR | Nov 24, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT NORTH WALL IN THE BA... | REAR | Sep 25, 2013 |
| Aug 21, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER SASH AT EAST ONE WINDOW IN THE ... | 1REAR | Sep 25, 2013 |
| Aug 19, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTER AT PUBLIC HALL STAIRS, 2nd STORY | — | Sep 23, 2013 |
| Jul 15, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2L, 2nd STOR... | 2L | Aug 19, 2013 |
| Jul 15, 2013 | A | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HEAVY DUTY LOCK AT DOOR IN THE ENTRANCE LOCATED AT A... | 2L | Oct 18, 2013 |
| Jul 15, 2013 | A | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HEAVY DUTY LOCK AT DOOR ENTRANCE TO BUILDING , 1st S... | — | Oct 18, 2013 |
| Jul 15, 2013 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FRO... | 2L | Aug 19, 2013 |
| Jul 15, 2013 | A | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING IN THE BATHR... | 2L | Oct 18, 2013 |
| Jul 15, 2013 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2L, 2nd ... | 2L | Aug 19, 2013 |
| Jul 15, 2013 | A | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... | 2L | Oct 18, 2013 |
| Jul 15, 2013 | A | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET UNDER SINK IN THE KITCHEN LOCATED AT AP... | 2L | Oct 18, 2013 |
| May 2, 2013 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT BUILDING ENTRANCE DOOR , 1st STORY | — | May 10, 2013 |
| Apr 29, 2013 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK AT BUILDING ENTRANCE DOOR , 1st STORY | — | May 7, 2013 |
| Apr 29, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND A... | 2RR | Jun 3, 2013 |
| Apr 29, 2013 | B | VIOLATION CLOSED | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELE... | 2RR | Jun 3, 2013 |
| Apr 29, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | 2RR | Jun 3, 2013 |
| Apr 29, 2013 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2RR, 2nd STORY | 2RR | Jun 3, 2013 |
| Apr 22, 2013 | C | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING : SCUTTLE COVER NAIL SHUT AT PUBLIC HALL, 2nd STORY | — | Apr 28, 2013 |
| Apr 22, 2013 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH GLASS PANE AT SOUTH ONE WINDOW IN THE 4t... | 2R | Apr 28, 2013 |
| Apr 22, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2R, 2nd ST... | 2R | May 27, 2013 |
| Apr 22, 2013 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FRO... | 2R | May 27, 2013 |
| Apr 22, 2013 | A | VIOLATION CLOSED | SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITIO... | 2R | Jul 26, 2013 |
| Apr 22, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING APPX. TEN SQ... | 2R | May 27, 2013 |
| Mar 22, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BUILDING ENTRANCE DOOR LOCKING DEVICE AT PUBLIC HAL... | — | Apr 26, 2013 |
| Mar 4, 2013 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION UNDER WASH BASIN IN THE BATHROOM LOCATED AT APT 1R... | 1RR | Apr 8, 2013 |
| Mar 1, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT | — | Apr 5, 2013 |
| Mar 1, 2013 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT | — | Apr 5, 2013 |
| Mar 1, 2013 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR LOCK ASSEMBLY AT LOBY DOOR | — | Apr 5, 2013 |
| Mar 1, 2013 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1RR, 1st STO... | 1RR | Apr 5, 2013 |