ECB violations
Williamsburg Houses, Brooklyn • Block 03026 • Lot 0001
22 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 1, 2025 | 39162070K | RESOLVE | CLASS - 2 | FOUND BLEND PUMP SUPPLY LINE WITH EVIDENCE OF RUST ON BOILER JACKET FROM POSSIBLE LEAK, MAINTAIN BOILER; CORRECT ALL ... | $0 | $0 | Dec 10, 2025 |
| Feb 28, 2024 | 39525981L | RESOLVE | CLASS - 1 | RESPONDING AN INCIDENT, WHERE WORKER CUT HIS SKIN AT LEFT SIDE OF HIS HEAD WITH GRINDER INSPECTION REVEALED: THAT THE... | $2,500 | $0 | Jan 17, 2025 |
| Oct 13, 2023 | 39522589N | RESOLVE | CLASS - 2 | INCIDENT REPORT THAT WORKER GOT STRUCK IN HIS HEAD WITH A CHIPPING GUN BIT. INVESTIGATION REVEAL THAT WORKER WAS CHIP... | $5,000 | $0 | Jun 10, 2024 |
| Sep 8, 2023 | 39521507X | RESOLVE | CLASS - 2 | AT TIME OF INCIDENT A WORKER FELL FROM A LADDER ON THE 4FLOOR INJURING, HIS BACK UPON REVIEWING THE CAUSE OF INCIDENT... | $1,250 | $0 | Nov 15, 2023 |
| Sep 8, 2023 | 39521508H | RESOLVE | CLASS - 1 | AT THE TIME OF INCIDENT A WORKER GOT INJURED DURING DEMO OPERATION, ON THE 1FL APARTMENT APPROXIMATELY 9:00AM FRIDAY ... | $0 | $0 | Nov 15, 2023 |
| Sep 8, 2023 | 39521509J | RESOLVE | CLASS - 1 | AT THE TIME OF INCIDENT A WORKER USING A JACKHAMMER ON THE 2NFL DURING DEMO OPERATION, WHERE A PIECE OF DEBRIS FELL B... | $5,000 | $0 | Nov 15, 2023 |
| Oct 21, 2020 | 39030793J | RESOLVE | CLASS - 2 | BOILER RATING TAG IS MISSING-WATER FEED PIPE IS LEAKING RIGHT SIDE OF BOILER-STEAM CONTROL PIPE LEAKING AT WALL ABOVE... | $625 | $0 | Nov 13, 2020 |
| Oct 21, 2020 | 39030790Y | RESOLVE | CLASS - 2 | NEW PREFERRED GAS/OIL BURNER IS INSTALLED WITHOUT A DOB PERMIT; CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRE... | $1,250 | $0 | Nov 13, 2020 |
| Oct 21, 2020 | 39030791X | RESOLVE | CLASS - 2 | DOMESTIC HW GENERATOR SAFETY DISCHARGE PIPES INCORRECT-BOTH SHUT OFF VALVES AT BOILER FEED TANK ARE LEAKING-BOTH FEED... | $625 | $0 | Nov 13, 2020 |
| Oct 21, 2020 | 39030792H | RESOLVE | CLASS - 2 | STEAM RETURN LEAKING IN TUNNEL REAR OF BOILER-BLOW DOWN VALVE LEAKING AT CONDENSATE TANK-WIRES EXPOSED AT ELECTRIC OI... | $625 | $0 | Nov 13, 2020 |
| Sep 23, 2019 | 39009884Z | RESOLVE | CLASS - 1 | ROCKMILLS BOILER #1. MISSING CONTROL COVERS. MISSING BODY DRAINS ON SAFETY VALVES. CEASE USE: DO NOT OPERATE BOILER U... | $0 | $0 | Oct 4, 2019 |
| May 7, 2019 | 39002678X | RESOLVE | CLASS - 2 | BNR DRAW ASMBY NOT SECURE-BOILER SAFTY VLVES MISG BODY DRAIN DISCHARG PIPES-FRONT TUBE DOOR MISSG BOLTS-GAUGE GLASS A... | $0 | $0 | May 9, 2019 |
| May 7, 2019 | 39002677Y | RESOLVE | CLASS - 1 | BLR SEALD CORECT HAZ CON IMEDTLY+CAL DOB2123932784LIFT CEASEUSE ODR-FRT TUB DOR MISG BOLT-WEBSTER BNR DEF-MNHOL LKG-K... | $0 | $0 | May 9, 2019 |
| May 7, 2019 | 39002679H | RESOLVE | CLASS - 2 | WTR FEED TNK WIRES EXPO+BLOW DWN NOT PPD DWN-SML CONDEN PMP LKING-BLR FEED PIPE LKING RR RT SIDE-OIL PIP AT PUMP NOT ... | $0 | $0 | May 9, 2019 |
| Feb 26, 2019 | 35401755N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER ILUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDOR FOR ... | $0 | $0 | Jun 24, 2019 |
| Feb 26, 2019 | 35401757R | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO OR DOB RECORDS INDICATES PREMISES LEGALLY APPROVED CLASS A MULTIDWELLING I... | $0 | $0 | Jun 24, 2019 |
| Feb 26, 2019 | 35401756P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345 NOTED: AT 1ST FL UPK ROO... | $0 | $0 | Jun 24, 2019 |
| Feb 22, 2019 | 35401754L | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF CLOSING . NOTED: AT 1ST FLOOR FAMILY ROOM EXIT DOOR WITH NO SELF CLOSER INSTALLED.REMEDY: REPAIR/R... | $0 | $0 | Jul 29, 2019 |
| Sep 17, 2018 | 39000373X | RESOLVE | CLASS - 2 | SEC DISCHARGE ON RELIEF VALVE NOT PIPED DOWN.OUTER SHELL RUSTED.GAS PRESSURE VALVE MISSING&OR DEFECTIVE. | $3,125 | $0 | Sep 25, 2018 |
| Sep 17, 2018 | 39000371M | RESOLVE | CLASS - 2 | BOILER OPERATIVE;BEIG OVERHAULED,SECONDARY DISCHARGE ON RELIEF VAVLE NOT PIPED DOWN.GAS PRESSURE GAUGES MISSING & OR ... | $0 | $0 | Sep 25, 2018 |
| Sep 17, 2018 | 39000372Y | RESOLVE | CLASS - 2 | BOILER INOPERATIVE NO SEN,DISCHARGE ON REL.VALVE.OUTER SHELL RUSTED.GAS PRESSURE GAUGES MISSING /DEFECTIVE | $3,125 | $0 | Sep 25, 2018 |
| Mar 30, 1994 | 34108578M | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPEID WITHOUT A VALID C OF O ALT 581/1986. OPERATION OF A PA WITHOUT A CURRENT PERMIT. REMEDY: OB... | $0 | $0 | Jun 27, 1994 |