Maintenance code violations
207-215 Troutman Street, Brooklyn • Block 03174 • Lot 0001
138 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Apr 12, 2024 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 16, 2024 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Mar 27, 2023 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jun 30, 2023 |
| Dec 27, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WEST WALL (APPROX... | 2R | Jan 31, 2023 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT ENTRANCE DOOR TO BUILDING ... | — | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TANK 'S COVER AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 2L, 2nd ... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILES AT, NORTH, EAST, SOUTH ,AND WEST WALLS, IN ... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD BASE CABINET, AT SOUTH WALL, IN THE KITCHEN LOCATED A... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW, 2ND FROM, NORTH AT E... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY,... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED MASONRY AT, SOUTH WALL, SOUT... | — | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR LEADING TO BASEMENT , AT SOUTH WALL AT PUBLIC HALL, ... | — | Sep 4, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS ... AT... | — | Sep 4, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT EN... | — | Sep 12, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UNHINGED WOOD DOOR, 1ST FROM NORTH AT EAST WALL, IN THE 4t... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING DETACHED RUNG AT DROP... | — | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FRO... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT LOWER SASH WINDOW 1ST FROM NORTH AT EAST IN THE ... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET, AT EAST WALL, IN THE 3rd ROOM FROM EAS... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT UPPER SASH WINDOW, 2ND FROM SOUTH AT WEST, IN TH... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT, LOWER SASH WINDOW, 2ND FROM SOUTH AT W... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING GLASS AT ENTRANCE AND VESTIBULE DOORS , , 1st STORY | — | Oct 3, 2022 |
| Aug 29, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND WALLS IN TH... | 2L | Dec 2, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTEN WOOD FLOOR IN THE KITCHEN LOC... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED GLASS AT, TRANSOM ABOVE, ENTRANCE DOOR TO BUILDIN... | — | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2L | Sep 24, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Oct 3, 2022 |
| Aug 29, 2022 | A | VIOLATION CLOSED | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LO... | 2L | Dec 2, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE L... | 2L | Sep 12, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2L | Oct 3, 2022 |
| Aug 29, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR FIRE RETARDANT MATE... | 2L | Sep 4, 2022 |
| Aug 29, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KNOB AT DOOR , 1st STORY | — | Oct 3, 2022 |
| Aug 26, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN... | 2R | Nov 29, 2022 |
| Aug 26, 2022 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER AT EAST WALL IN THE 1st ROOM FROM ... | 2R | Nov 29, 2022 |
| Aug 26, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE KITCHEN LOC... | 2R | Nov 29, 2022 |
| Aug 26, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WES... | 2R | Sep 30, 2022 |
| Aug 26, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN TH... | 2R | Sep 30, 2022 |
| Aug 26, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHRO... | 2R | Nov 29, 2022 |
| Aug 26, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR AT LOWER BASE CABINET BENEATH WASH BASIN IN THE BATHROOM LOCATED... | 2R | Nov 29, 2022 |
| Aug 26, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1... | 2R | Sep 30, 2022 |
| Aug 26, 2022 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Sep 30, 2022 |
| Aug 26, 2022 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT STEAM RISER AT EAST WALL IN THE 1st ROOM FROM EAS... | 2R | Nov 29, 2022 |
| Aug 26, 2022 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Sep 30, 2022 |
| Aug 26, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN TH... | 2R | Sep 30, 2022 |