1329-1333 Myrtle Avenue, Brooklyn
Brooklyn • Block 03245 • Lot 0002 • Zip: 11221
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Union Square 39 min 7 walking, 32 riding
- Fulton Street 39 min 7 walking, 32 riding
- Downtown Brooklyn 43 min 7 walking, 36 riding
- Grand Central 50 min 7 walking, 43 riding
- Times Square 51 min 7 walking, 44 riding
- Penn Station 53 min 7 walking, 46 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Lucky Charlie
No description yet
Nene’s Deli Taqueria
No description yet
Lori Jayne
No description yet
Carmenta’s
Carmenta’s is a cozy Italian restaurant in the heart of Brooklyn, serving up authentic dishes made with fresh, locall...
Bunna Cafe
Bunna Cafe is a cozy Ethiopian eatery in Brooklyn, offering flavorful vegan dishes and traditional injera bread. The ...
Knickerbocker Bagel
No description yet
Mood Ring
Mood Ring is a trendy bar in Brooklyn known for its unique cocktails and vibrant atmosphere. Featuring a retro decor ...
Taqueria Al Pastor
Taqueria Al Pastor is a cozy Mexican restaurant in Brooklyn known for its authentic al pastor tacos. With vibrant dec...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2022
-
HPD violation Nov 3, 2022
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LAUNDRY ROOM...
-
HPD violation Nov 3, 2022
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE THE FIRE DOO...
-
HPD violation Nov 3, 2022
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE THE FIRE DOO...
-
HPD violation Nov 3, 2022
Class C
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT DOOR IN THE ENTRANCE LOCATED AT APT 1B, ...
2020
2019
-
HPD violation Sep 9, 2019
Class C
§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG...
-
HPD violation May 28, 2019
Class A
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R...
2018
-
DOB violation Apr 6, 2018
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
2017
-
Alteration Type I
SOE APPLICATION FILED IN CONJUNCTION WITH ALT ONE JOB NUMBER 320924023
-
Alteration Type II
INSTALLATION OF AUTOMACTIC/SMOKE/HEAT/CO DETECTION AND SPRINKLER ALARM SYSTE M.
-
Alteration Type III
BPP FILED IN CONJUNCTION WITH ALT ONE JOB NUMBER 320924023
-
Alteration Type III
PROPOSED INSTALLATION OF PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
DOB violation Feb 24, 2017
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
2015
-
CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS&/OR APPROVED AMENDMENTS. AT TIME OF INSPECTON IT WAS OBSERVE...
-
CLASS - 2
FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION. AT THE TIME OF INSPECTION CONSTRUCTIO...
-
CLASS - 2
SEC. 3301.2 FAILURE TO PROVIDE 3FOOT 6INCH GUARDRAIL OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENINGS. AT TIME OF ...
-
CLASS - 2
SEC. 1704.1.1 FAILURE TO FILE A SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY STATEMENT PRIOR TO PERMIT ISSUANCE & P...
2011
-
DOB violation Dec 13, 2011
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
2009
-
DOB violation Dec 31, 2009
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
-
DOB violation Jan 1, 2009
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
2008
2007
-
Non-Hazardous
FAILURE TO MAINTAIN BLDG NOTED: LINTEL OVER 2ND FL FRONT EAST WINDOW IS CRACKED IN HALF & IMPROPERLY SET IN & OFF SET...
2006
-
Non-Hazardous
FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER TO CORRECT THE VIOLATNG CONDITION OF ECB#34449967L FOR CONVERTING A ...
2004
-
DOB violation Feb 13, 2004
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
2003
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records