Skip to content

ECB violations

203 Wilson Avenue, Brooklyn • Block 03257 • Lot 0004

20 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Oct 17, 2022 39072133J ACTIVE CLASS - 2 FOR WORK WITHOUT PERMIT. AT TIME OF INSPECTION OBSERVED AT 1ST FLOOR APT STAIR CASE CONNECTED TO GO DOWN TO CELLAR FL... $1,250 $0 Feb 22, 2023
Sep 11, 2014 35074528H RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BLDG DEPT RECORDS. NOTED: ATTHE 3RD FL,APPROVED PLANS UNDER JOB #320863883A... $12,000 $0 Oct 27, 2014
Sep 11, 2014 35074527X RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. NOTED: AT 3RD FL AT FRONT SIDE OF T... $5,000 $0 Oct 27, 2014
Sep 11, 2014 35066953Z RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER:LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 403.... $1,000 $0 Dec 17, 2014
Sep 11, 2014 35074529J ACTIVE CLASS - 2 WORK W/O PERMIT. PREMISES INSTALLED AT REAR YARD #7 A/C CONDENSING CONNECTED INTO THE ENTIRE BLDG W/DUCK WORK INSTALL... $800 $0 Dec 17, 2014
Sep 11, 2014 35039148M RESOLVE CLASS - 2 ELECTRICAL WORK W/O PERMIT. OBSERVED AT 11:15AM NO APP ON FILE FOR HEATING AND COOLING UNIT INSTALLED ON ALL FLOORS. ... $0 $0 Oct 27, 2014
Sep 11, 2014 35066952R RESOLVE CLASS - 2 FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER.RE:INSTALLATION OF PLUMBING MATERIALS PER PC 102.3;27-902 12:25 PM @ TIM... $0 $0 Oct 27, 2014
Sep 11, 2014 35074526Y RESOLVE CLASS - 2 SEC. 401.2;401.3 VENTILATION NOT PROVIDED. NOTED: AT CELLAR LEVEL USE AS COMMON LAUNDRY ROOM ARE THE (GAS) METERS FRO... $400 $0 Dec 15, 2014
Sep 11, 2014 35039149Y RESOLVE CLASS - 2 UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS MATERIALS ALSO OBSERVED 8; FLOURESCENT APPLIANCES... $0 $0 Oct 27, 2014
Sep 12, 2012 35039732L RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C OF C W/THE DEPT OF BUILDINGS FOR NOTICE OF VIOLATION #349119... $2,000 $0 May 20, 2013
May 8, 2012 34911943Y RESOLVE CLASS - 1 FAILURE TO MAITAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT 1ST FLR LEVEL LEFT FRONT & ENTIRE REAR LEFT & RIGHT APTS,... $1,000 $0 Dec 10, 2012
Dec 16, 2007 34622694L RESOLVE Non-Hazardous WORK W/O A PERMIT. WORK NOTED: APT 1L ERECTED A CLASS A APT 3 PC BATHROOM FULL KITCHEN W/GAS STOVE CREATED INTERIOR P... $0 $0 Feb 4, 2008
Dec 15, 2007 34622693J RESOLVE Non-Hazardous RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES {5 FAMILIES LEGAL... $0 $0 Feb 4, 2008
Dec 15, 2007 34622695N RESOLVE Hazardous FAILURE TO PROVIDE AT LEAST TWO MEANS OF EGRESS FROM ROOM OR SPACE WHERE REQUIRED 1FL NO 2ND MEAN OF EGRESS ONLY AND ... $480 $0 Feb 4, 2008
Sep 20, 2007 34584046Z RESOLVE Hazardous FAILURE TO MAINTAIN BLDG HAZ. NOTED: 1) ROTTED WOOD JOISTS UNPROTECTEDSPLIT WOOD (GIRDER) AT VARIOUS LOCATIONS FULL L... $350 $0 Jun 24, 2013
Feb 3, 2007 34560511Z RESOLVE Hazardous FAILURE TO MAINTAIN BLDG.NOTE:ROTTING JOISTS,SPLIT WOODEN GIRDER & MISSING FIRE STOPPING MATERIAL OBSERVED IN THE CEI... $0 $0 Jun 4, 2007
Dec 13, 2006 32050422Y RESOLVE Non-Hazardous B4A,19B,38,50A,B,C,D,E,F,G,H,I,J.50A BOILER ROOM FIRE DOOR DEFECTIVE.50B FLUE PIPE NEED SUPPORT.50C HOLES IN BOILER R... $180 $0 Jan 29, 2007
Nov 14, 2006 34547009R RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG.DEFECT NOTED:AT CELLAR LEVEL OF ABOVE PREMISES NEAR FRONT A STEEL SUPPORT COLUMN IS BROKEN &... $800 $0 Mar 12, 2007
Sep 25, 2006 34542007K RESOLVE Hazardous FAILURE TO MAINTAIN BLDG-HAZARDOUS.DEFECT NOTED:AT CELLAR LEVEL STEAL LOLLY COLUMN HAS ROTTEN AWAY FROM 8" X 8" GIRDE... $800 $0 Nov 27, 2006
Aug 8, 1996 32014290N RESOLVE Non-Hazardous 4A,19B, $250 $0 Oct 7, 1996