Maintenance code violations
165 Stanhope Street, Brooklyn • Block 03257 • Lot 0051
62 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jul 21, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Aug 25, 2025 |
| Jul 21, 2025 | C | VIOLATION DISMISSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Aug 4, 2025 |
| May 2, 2024 | A | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT EAST WALL IN THE FOYER LOCATED A... | 1L | Aug 5, 2024 |
| May 2, 2024 | C | VIOLATION CLOSED | § 27-2044, 2041.1 HMC: §238 MDL and 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR ... | — | May 16, 2024 |
| May 2, 2024 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STOR... | 1L | Jun 6, 2024 |
| May 2, 2024 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 1L | Jun 6, 2024 |
| Jun 21, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER AT ELECTRICAL OUTLET AT NORTH WALL IN THE 2nd ROOM FROM EAST LO... | 2L | Sep 24, 2022 |
| Jun 21, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING MAXIMUM TEMPERATURE OF 130 DEGR... | 1L | Jun 27, 2022 |
| Jun 21, 2022 | C | VIOLATION DISMISSED | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCAT... | 2L | Jul 17, 2022 |
| Jun 21, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER AT ELECTRICAL OUTLET AT NORTH WALL IN THE KITCHEN LOCATED AT AP... | 2L | Sep 24, 2022 |
| Jun 21, 2022 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd ... | 2L | Jul 17, 2022 |
| Mar 2, 2022 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jun 5, 2022 |
| Apr 13, 2021 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 17, 2021 |
| Jun 9, 2020 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2R | Jul 14, 2020 |
| Jun 9, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT BUILDING ENTERANCE DOOR , 1st STORY | — | Jul 14, 2020 |
| Jun 9, 2020 | C | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS DOOR NOT SELF CLOSING IN THE ENTRANCE LOCATED AT APT... | 2R | Jul 5, 2020 |
| Jun 9, 2020 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Jul 14, 2020 |
| May 13, 2019 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NO... | 1R | Jun 17, 2019 |
| May 13, 2019 | A | VIOLATION DISMISSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Aug 16, 2019 |
| May 13, 2019 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT BUILDING ENTRANCE DOOR FROM STREET AT PUBLI... | — | Jun 17, 2019 |
| May 13, 2019 | A | VIOLATION DISMISSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Aug 16, 2019 |
| May 13, 2019 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1R, 1st STORY, 1... | 1R | Jun 17, 2019 |
| May 13, 2019 | B | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 1R, 1st STORY, 1st AP... | 1R | Jun 17, 2019 |
| Dec 18, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BASE MOULDINGS AT EAST AND WEST WALLS AT VESTIBULE AT PUBLIC HALL, 1s... | — | Mar 23, 2019 |
| Dec 18, 2018 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY,... | 2L | Jan 22, 2019 |
| Dec 18, 2018 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2L | Jan 22, 2019 |
| Dec 18, 2018 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ; FLAP DOOR LOCKED TO CELLAR AT EAST YARD | — | Dec 26, 2018 |
| Dec 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT VESTIBULE AT ... | — | Jan 22, 2019 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT... | — | Nov 5, 2018 |
| Oct 1, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 2... | — | Jan 4, 2019 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 2nd... | — | Nov 5, 2018 |
| Oct 1, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT SOUTH WALL AT VESTIBULE , 1s... | — | Jan 4, 2019 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT SOUTH WALL... | — | Nov 5, 2018 |
| Oct 1, 2018 | A | VIOLATION DISMISSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jan 4, 2019 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT CEILIN... | — | Nov 5, 2018 |
| Oct 1, 2018 | A | VIOLATION DISMISSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Jan 4, 2019 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT ENTRANCE DOOR TO BUILDING AT PUBLIC HALL, 1... | — | Nov 5, 2018 |
| Oct 1, 2018 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3... | — | Jan 4, 2019 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT... | — | Nov 5, 2018 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 3rd STORY | — | Nov 5, 2018 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCAT... | 1R | Nov 5, 2018 |
| Oct 1, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 1R | Nov 5, 2018 |
| Sep 12, 2014 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2L | Oct 17, 2014 |
| Sep 12, 2014 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATE LOCK INSTALLED AT IRON GATE AT FENC... | — | Sep 20, 2014 |
| Sep 12, 2014 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY,... | 2L | Oct 17, 2014 |
| Sep 12, 2014 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY,... | 2L | Oct 17, 2014 |
| Sep 12, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT EAST WALL IN THE 3rd ROOM FROM NORTH LO... | 2L | Oct 17, 2014 |
| Aug 28, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RUBBER GASKETS AT REFRIGERATOR DOORS (TOTAL TWO) IN THE K... | 2L | Oct 2, 2014 |
| Aug 25, 2014 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR AT NORTH WALL AT PUBLI... | — | Sep 2, 2014 |