Issued Class Status Violation Apartment Correct by
Jun 4, 2019 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT VESTIBULE Jul 9, 2019
Jun 4, 2019 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT FRONT ENTRANCE TO BUILDING Jul 9, 2019
Jun 4, 2019 A VIOLATION CLOSED § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... Sep 7, 2019
May 23, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT BULKHEAD AT PUBLI... Aug 26, 2019
May 23, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT BULKHEAD AT PUBLIC HALL, 4th STORY Jun 27, 2019
May 23, 2019 C VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING,... May 31, 2019
Apr 25, 2019 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT FRONT ENTRANCE TO BUILDING , 1st STORY May 30, 2019
Apr 25, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ..NORTH, EAST, AND SOUTH WAL... Jul 29, 2019
Apr 25, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ..THE CEILING, WEST AND EAST... Jul 29, 2019
Apr 25, 2019 A VIOLATION CLOSED § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... Jul 29, 2019
Apr 24, 2019 C VIOLATION DISMISSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 4L May 22, 2019
Apr 22, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 4th ROOM FROM E... 4L May 27, 2019
Apr 22, 2019 A VIOLATION CLOSED § 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALS... 4L Jul 26, 2019
Apr 22, 2019 B VIOLATION CLOSED § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE UNDER WASHBASIN IN THE BATHROOM LOCATE... 4L May 27, 2019
Apr 22, 2019 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROX 16 SQ FT) ON CEILING IN ... 4L May 27, 2019
Apr 22, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM E... 4L May 27, 2019
Apr 22, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE 4th ROOM FROM EAST ... 4L May 27, 2019
Apr 22, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BALANCE AT LOWER SASH WINDOW IN THE 4th ROOM FROM EAST AT ... 4L May 27, 2019
Apr 18, 2019 A VIOLATION CLOSED § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... Jul 22, 2019
Apr 18, 2019 A VIOLATION CLOSED § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... Jul 22, 2019
Apr 11, 2019 A VIOLATION CLOSED § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... Jul 15, 2019
Apr 11, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WEST WALL AT... Jul 15, 2019
Apr 11, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING I... May 16, 2019
Apr 11, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND SOUTH WALL A... Jul 15, 2019
Apr 11, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... May 16, 2019
Apr 11, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST AND SOUTH WALLS AT ... Jul 15, 2019
Apr 11, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT EAST AND ... May 16, 2019
Apr 11, 2019 A VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCKSET AT DOOR IN THE ENTRANCE LOCATED AT APT 4R,... 4R Jul 15, 2019
Apr 1, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... May 6, 2019
Apr 1, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 4th STORY May 6, 2019
Apr 1, 2019 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, ... Jul 5, 2019
Mar 21, 2019 A VIOLATION DISMISSED § 27-2005 ADM CODE REFIT ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST 2L Jun 24, 2019
Mar 21, 2019 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... 2L Apr 25, 2019
Mar 21, 2019 B VIOLATION DISMISSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... 2L Apr 25, 2019
Mar 21, 2019 B VIOLATION DISMISSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH AND SOUTH WAL... 2L Apr 25, 2019
Mar 21, 2019 B VIOLATION DISMISSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, WEST AND N... 2L Apr 25, 2019
Mar 21, 2019 C VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED AT THE METAL DOOR A... Mar 29, 2019
Mar 14, 2019 B VIOLATION DISMISSED § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS . . . IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, ... 4R Apr 18, 2019
Mar 14, 2019 B VIOLATION DISMISSED § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4R,... 4R Apr 18, 2019
Mar 14, 2019 C VIOLATION DISMISSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 4R Apr 11, 2019
Mar 14, 2019 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZER IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, ... 4R Apr 18, 2019
Mar 14, 2019 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BA... 4R Apr 18, 2019
Mar 13, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT PUBLI... Apr 17, 2019
Mar 13, 2019 B VIOLATION CLOSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 4R, 4th STORY, ... 4R Apr 17, 2019
Mar 13, 2019 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM E... 4R Apr 17, 2019
Mar 13, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SIX AND SEVENTH WOOD TREAD UP FROM INTERMEDIATE LANDING AT PUBLIC HALL, ... Apr 17, 2019
Mar 13, 2019 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL STAIRS, 4th STORY Apr 17, 2019
Mar 6, 2018 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCK DOOR LEADING BOILER ROOM AT CELLAR Mar 14, 2018
Mar 6, 2018 C VIOLATION CLOSED § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, ... 4R Mar 5, 2018
Mar 6, 2018 C VIOLATION DISMISSED § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4t... 4R Mar 5, 2018