| Apr 27, 2010 | 34840607J | RESOLVE | CLASS - 2 | FAILURE TOSAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS FULL GUT RENOVATION BEING DONE AT PREM... | $0 | $0 | Jul 26, 2010 |
| Apr 27, 2010 | 34840608L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. NOTED: AT REAR YARD EXCESS CONSTRUCTION DEBRIS BE... | $400 | $0 | Jul 26, 2010 |
| Apr 27, 2010 | 34840606H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. NOTED: FULL GUT RENOVATION BEING DONE AT PREMISES THROUGHOUT BLDG. ALL FIRE STOPPING REMOVED NEW W... | $800 | $0 | Jul 26, 2010 |
| Jan 21, 2010 | 34823076P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. NOTED: AT FRONT YARD A MISC. PIPE OF DEBRIS APPRO... | $4,000 | $0 | Mar 15, 2010 |
| Aug 28, 2009 | 34804901M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/COMZISSIONER ORDER TO FILE CERT OF CORRECTION FOR VIO#34770239Y REM: FILE CERT OF CORRECTION | $4,000 | $0 | Oct 19, 2009 |
| Aug 28, 2009 | 34804900K | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN NOTE ACCUMULATION OF OLD FURNITURE GARBAGE & MISC DEBRIS DUMPED AT FRONT OF VACANT BLDG REM: MAIN... | $500 | $0 | Oct 19, 2009 |
| Mar 20, 2009 | 34770239Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURT. NOTED: APPROX 20 CU YDS OF GARBAGE & COMBUSTIBLE DEBRIS DUMPED IN FRONT COU... | $5,000 | $0 | May 11, 2009 |
| Aug 14, 2008 | 34687801P | RESOLVE | CLASS - 1 | WORK W/O A PERMIT WORK NOTED AT CELLAR PARTITIONS ERECTED SUBDIVIDING INTO ROOM,PLUMBING LINE INSTALLED CREATING KITC... | $8,000 | $0 | Sep 29, 2008 |
| Aug 14, 2008 | 34687800N | RESOLVE | CLASS - 3 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BUILDING DEPARTMENT RECORDS BUILDING RECORDS CLASSIFIES CELLAR AS BOILER/AC... | $500 | $0 | Sep 29, 2008 |
| Jun 11, 2008 | 34562586M | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO & DOB RECORDS CLASS A APT CREATED AT CELLAR PARTITIONS ERECTED CREATING RM... | $2,500 | $0 | Sep 8, 2008 |
| Mar 3, 2007 | 32053333X | RESOLVE | Hazardous | B4B/40/3A/3B/7A/38/50A/50B/50C/50D/.50A-CHIMNEY CLOGGED,FUMES.50B-HOLES IN BOILER ROOM WALLS & CEILING.50C-FLUE PIPE ... | $2,500 | $0 | Apr 30, 2007 |
| Oct 21, 2005 | 32048758P | RESOLVE | Non-Hazardous | B4A/50/32/50A/19B/25A/24B/31B/45A/44B/33A. 50-GAS HOT WATER HEATER LEAKING.50- BOILER AND OIL BURNER RUSTED AND NOT O... | $2,500 | $0 | Dec 5, 2005 |