ECB violations
99 Thatford Avenue, Brooklyn • Block 03523 • Lot 0007
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 7, 2024 | 39126791M | RESOLVE | CLASS - 2 | OBSERVED TEMPORARY VALVE CAPS(RED) INSTALLED THROUGHOUT STAIR LANDINGS. AS PER 3308.7 COVERINGS SHALL BE REMOVED AFTE... | $625 | $625 | Sep 15, 2025 |
| Oct 7, 2024 | 39126793X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1 (2014 COD... | $1,250 | $1,250 | Sep 15, 2025 |
| Oct 7, 2024 | 39126790K | RESOLVE | CLASS - 2 | OBSERVED PAINTED SPRINKLER HEAD ON THE 7TH FLOOR HOUSE KEEPING ROOM. AS PER 102.3 OF THE PLUMBING CODE MAINTENANCE. I... | $625 | $625 | Sep 15, 2025 |
| Oct 7, 2024 | 39126795J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED CRACKING ON ROOF WALL APPROXIMATE 3 FEET. POTENTIAL W... | $1,250 | $0 | Mar 17, 2026 |
| Oct 7, 2024 | 39126801R | RESOLVE | CLASS - 2 | I OBSERVED IN THE ELECTRICAL CLOSETS THE UNPERMITTED USE OF EMT THROUGH THE CONCRETE FLOOR WITHOUT PROTECTION. AS PER... | $500 | $500 | Mar 17, 2026 |
| Oct 7, 2024 | 39126800P | RESOLVE | CLASS - 1 | I OBSERVED NO REMOTE SHUT-DOWN FOR THE GAS-FIRED SYSTEMS IN THE BOILER ROOM AT THE POINT OF EGRESS AS REQUIRED IN MC ... | $6,250 | $6,250 | Mar 17, 2026 |
| Oct 7, 2024 | 39126803K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE TAMPER RESISTANT/ PROOFED OUTLETS IN THE COMMON HALLWAYS AS PER LL39/ 2015. THIS AN IMMEDIATE SHOC... | $1,600 | $1,600 | Sep 15, 2025 |
| Oct 7, 2024 | 39126802Z | RESOLVE | CLASS - 2 | I OBSERVED IN THE LAUNDRY ROOM THE EQUIPMENT DISCONNECTS NOT ACCESSIBLE DUE THE INSTALLATION OF THE FIXED EQUIPMENT, ... | $500 | $500 | Sep 15, 2025 |
| Oct 7, 2024 | 39126799R | RESOLVE | CLASS - 1 | I OBSERVED NO WATER METER JUMPER AS REQUIRED AS PART OF THE ELECTRICAL GROUNDING SYSTEM., PROPERLY INSTALL GROUND ELE... | $4,800 | $4,800 | Sep 15, 2025 |
| Oct 7, 2024 | 39126796L | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. OBSERVED NON-SELF-CLOSING DOORS ON ROOF, EXITS DOORS AND UTILITIES/ MECHANICAL ROOMS THRO... | $625 | $625 | Sep 15, 2025 |
| Oct 7, 2024 | 39126794H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $2,500 | Sep 15, 2025 |
| Jun 2, 2021 | 35559218H | RESOLVE | CLASS - 1 | BC3307.4 WARNING SIGN,PERSONNEL&BARRIERS NOTE:ATO MY INSP OF 7STYBLG@ROOF LEVEL,CONST WORK IN PROGRESS,I OBSERVED WOR... | $2,500 | $0 | Oct 13, 2021 |
| Jun 2, 2021 | 35559219J | RESOLVE | CLASS - 1 | FAILURE TO COMMUNICATE REQUIRED INFO DURING SITE SAFETY ORIENTATION ORREFRESHER NOTE:ATO MY INSP OF 7STYBLDG W/ACTIVE... | $2,500 | $0 | Oct 13, 2021 |
| Dec 4, 2020 | 35538126H | RESOLVE | CLASS - 1 | BC 1704.1.2.3 FAILURE TO PERFORM SPECIAL INSPECTION DUTIES:BASED ON CEU'S AUDIT ON THE SPECIAL INSPECTION REPORTS BY ... | $2,500 | $0 | Apr 21, 2021 |
| Dec 1, 2020 | 35543231X | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT/TEMPORARY CONSTRUCTION-NO GUARDRAILS.NOTE:AT THE TME OF MY INSPECTION ... | $2,500 | $0 | Feb 23, 2022 |
| Sep 24, 2020 | 35488074M | RESOLVE | CLASS - 2 | PROVISION OF LAW:BC3309.1.FAILURE TO PROTECT OR ADEQUATELY PROTECT ADJOINING PROPERTIES DURING CONSTRUCTION OR DEMOLI... | $640 | $0 | Nov 1, 2021 |
| Sep 18, 2020 | 35537804N | RESOLVE | CLASS - 2 | BC 28-116.2.3 FAILURE TO PROVIDE AN ADEQUATE INSPECTION PROGRAM TR2.ASNOTED:AT TIME OF INSPECTION ON AN ACTIVE CONSTR... | $250 | $0 | Oct 6, 2021 |
| Sep 18, 2020 | 35537803L | RESOLVE | CLASS - 1 | WORK DOES NOT TO APPROVED CONSTRUCTION DOCUMENT AND/OR APPROVED AMENDMENTS:AS NOTED:AT TIME OF INSPECTION OBSERVED(1)... | $625 | $0 | Oct 6, 2021 |
| Sep 18, 2020 | 35537802J | RESOLVE | CLASS - 2 | BC 3301.7 FAILURE TO PROVIDE P.E APPROVED DETAIL DESIGN DRAWING.AS NOTED:AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCT... | $0 | $0 | Jan 27, 2021 |
| Sep 18, 2020 | 35537805P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.AS NOTED:AT TIME OF INSPECTION ON AN ACTIVE CONSTR... | $625 | $0 | Oct 6, 2021 |
| Jan 8, 2020 | 35469687L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33.AT TIME OF INSPECTION ON AN NB 7 STORY BUILDI... | $0 | $0 | Oct 13, 2021 |
| Jan 8, 2020 | 35469686J | RESOLVE | CLASS - 1 | BC3304.7/ACCESS DURING EXCAVATIONS.NOTED:AT TIME OF INSPECTION ON AN OPEN PERMIT FOR 7 STORIES NB I OBSERVED ACTIVE J... | $2,500 | $0 | Oct 13, 2021 |
| Jan 8, 2020 | 35469688N | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION NO GUARDRAILS AT TIME OF INSPECTION... | $2,500 | $0 | Nov 1, 2021 |
| Sep 13, 2019 | 35452852P | RESOLVE | CLASS - 2 | BC3309.9 FAILURE TO WEATHERPROOF ADJOINING PROPERTIES.@TIME OF INSPECTION OF A STALLED JOBSITE,I OBSERVED THE FOUNDAT... | $0 | $0 | Jan 15, 2020 |
| Nov 1, 2017 | 35286323Z | RESOLVE | CLASS - 2 | FENCE.AT TIME OF INSPECTION OBSERVED AT SITE NOT MAINTAINED(1)FENCE NOT PAINTED HUNTER GREEN(2)NO VISION PANEL(3)PERM... | $2,000 | $0 | Dec 18, 2017 |