ECB violations
202 Amboy Street, Brooklyn • Block 03539 • Lot 0045
32 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 15, 2026 | 39188784H | ACTIVE | CLASS - 3 | AO SMITH HOT WATER HEATER IS LEAKING WATER+THE OUTSIDE CHIMNEY BASE DOOR IS DEFECTIVE, MAINTAIN BOILER; CORRECT VIOLA... | $500 | $500 | Aug 19, 2026 |
| Feb 1, 2023 | 39079732N | RESOLVE | CLASS - 2 | OBSERVED: AT FIRST FLOOR,CMU PARTY WALL, CRACKED WALL WITH DISPLACED COURSES, LOSS OF MORTAR IN DIFFERENT LOCATIONS. ... | $0 | $0 | Apr 26, 2023 |
| Feb 1, 2023 | 39079016M | RESOLVE | CLASS - 2 | I OBSERVED ON ALL FLOORS THE INSTALLATION OF CONDUITS, BRANCH CIRCUIT WIRING AND EMERGENCY LIGHTS WITHOUT A PERMIT ON... | $0 | $0 | May 8, 2023 |
| Feb 1, 2023 | 39079017Y | RESOLVE | CLASS - 2 | I OBSERVED THROUGHOUT THE BASEMENT AREA THE USE OF BAND-IRON TO SUPPORT RACEWAYS/CABLES. THIS IS NOT AN APPROVED SUPP... | $400 | $0 | Sep 11, 2023 |
| Feb 1, 2023 | 39079018X | RESOLVE | CLASS - 2 | I OBSERVED ON ALL FLOORS THE FAILURE TO INSTALL JUNCTION BOXES AS REQUIRED FOR THE INSTALLATION OF THE EMERGENCY LIGH... | $0 | $0 | May 8, 2023 |
| Mar 11, 2022 | 35651026P | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF CLOSING.OBSERVED:AT ROOF LEVEL AND FIRST FLOOR,EXITDOORS DO NOT ALLOW EASY ESCAPE FROM BUILDING IN... | $312 | $0 | Aug 10, 2022 |
| Mar 11, 2022 | 35651027R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC... | $0 | $0 | Nov 15, 2022 |
| Feb 7, 2019 | 35386152L | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT. OBSERVED IN GAS METER ROOM IN CELLAR GAS PIPINGCUT OUT AND DOB RECORDS SHOW NO PERMIT BEING IS... | $0 | $0 | Jun 17, 2019 |
| Dec 15, 2018 | 35392777M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35361806K ISSUED ON 09-20-18 & TO FILE A C OF C PURSUAN... | $1,280 | $0 | Apr 15, 2019 |
| Sep 29, 2018 | 35361806K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. OBSERVED IN CELLAR RUNNING ALL THREAD COUPLING USED ON 3/4" GAS ... | $3,125 | $0 | Mar 25, 2019 |
| Jun 8, 2018 | 35335436N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR RUNNING ALL THREAD COUPLINGS USED ON 3/4" GAS P... | $625 | $0 | Aug 6, 2018 |
| Mar 29, 2018 | 35325221R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35297833M ISSUED ON 01/04/18 AND TO FIL... | $1,250 | $0 | Jul 16, 2018 |
| Jan 18, 2018 | 35282663R | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35287040N ISSUED 11/26/17 AND TO FILE... | $0 | $0 | May 14, 2018 |
| Jan 4, 2018 | 35297833M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLARRUNNING THREAD COUPLINGS USED ON 3/4" PIPING AT ... | $500 | $0 | May 16, 2018 |
| Nov 25, 2017 | 35281226Y | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35287004N ISSUED ON 07/26/17 AND TO FI... | $0 | $0 | Apr 16, 2018 |
| Nov 3, 2017 | 35280498N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35290842M ISSUED ON 09/16/17 AND TO FI... | $2,000 | $0 | Jun 25, 2018 |
| Oct 31, 2017 | 35285097P | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.RECORDS INDICATE NO APPL WAS MADE TO CORRECT & CERTIFY... | $800 | $0 | Apr 4, 2018 |
| Oct 12, 2017 | 35279821X | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35287040N ISSUED ON 07/26/17 & TO FILE A C OF C PURSUAN... | $0 | $0 | Apr 4, 2018 |
| Sep 16, 2017 | 35290842M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERED IN CELLAR RUNNING THREAD COUPLINGS USED ON 3/4" PIPI... | $2,500 | $0 | Jun 6, 2018 |
| Jul 26, 2017 | 35287043Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON GAS LINES AT METER ROOM PROHIBITED GAS CAPS INSTALL... | $500 | $0 | Mar 30, 2018 |
| Jul 26, 2017 | 35287042R | RESOLVE | CLASS - 1 | 411.1.6 MISC VIOLATION. INSTALLED 2" UNION ON GAS LINE AT GAS METER LOCATION.PROHIBITED FITTINGS. REMEDY:COMPLY WITH ... | $800 | $0 | Mar 30, 2018 |
| Jul 26, 2017 | 35287041P | RESOLVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.INSTALLED 4"-3"-2" NO HUB DRAIN LINES THROUGHOUT BST.INSTALLED ... | $500 | $0 | Mar 30, 2018 |
| Jul 26, 2017 | 35286719P | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,DEVICES,MATERIALS,APPLIANCES OR WIRING IN USE. OBSERVED I... | $400 | $0 | Jan 22, 2018 |
| Jul 26, 2017 | 35286720M | RESOLVE | CLASS - 2 | FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER(GFCI)PROTECTION ASREQUIRED. RECEPTACLES IN BASEMENTS BOILER ROOM ... | $2,400 | $0 | Mar 28, 2018 |
| Jul 26, 2017 | 35287044K | RESOLVE | CLASS - 1 | 408.2 MISC VIOLATION. TOE AND PLUMBING FIXTURE GAS CONNECTION EXISTS IN BOILER ROOM HOUSE LINE AT CEILING DOWN STREAM... | $800 | $0 | Mar 30, 2018 |
| Jul 26, 2017 | 35287040N | RESOLVE | CLASS - 1 | WORK NO PERMIT.OBSERVED IN BASEMENT.THROUGHOUT NEW 4"-3"-2" NO HUB DRAIN PIPING,NEW 3/4 GAS HOUSE PIPING THROUGHOUT-N... | $0 | $0 | Mar 30, 2018 |
| Jul 26, 2017 | 35287045M | RESOLVE | CLASS - 1 | 404.12 MISC. VIOLATION .OBSERVED IN BASEMENT GAS OUT AND VALUE ON WALL.NOT PROPERLY CAPPED OR PLUGGED AT TIME OF INSP... | $800 | $0 | Mar 30, 2018 |
| Feb 15, 2017 | 35228803M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED ON 02/15/17 HOLE IN CAST IRON PIPE IN BASEMENT.(GAS ME... | $500 | $0 | Aug 23, 2017 |
| Feb 15, 2017 | 35228804Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED ON 2/15/17 NO CURRENT BOILER RECORDS ON FILE AT THE DOB.TH... | $250 | $0 | Aug 23, 2017 |
| Feb 11, 2016 | 35171211Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:USE OF PROHIBITED DOOR &/OR HARDWARE PER BC 1008.1.8;27-371(J).FIRE... | $1,000 | $0 | Jul 25, 2016 |
| Feb 11, 2016 | 35171210M | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.EXTERIOR FIRE EXIT PASSAGEWAY DOOR,WHICH LEDS FROM CELLAR LEVEL TO ST... | $1,000 | $0 | Jul 18, 2016 |
| May 18, 2007 | 32053384X | RESOLVE | Non-Hazardous | 50/50A/.50-HOLES IN BOIELR ROOM.50A-SMOKE PIPE NOT SUPPORTED PROPERLY. | $0 | $0 | Jul 16, 2007 |