ECB violations
49 Sheffield Avenue, Brooklyn • Block 03669 • Lot 0007
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 1, 2024 | 39129264Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Jan 15, 2025 |
| Nov 1, 2024 | 39129265X | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. UNSAFE STORAGE STAGED (BOXES AND FLOORING MATERIAL) UNDERNEATH ... | $2,500 | $0 | Jan 15, 2025 |
| Oct 3, 2024 | 39126533J | RESOLVE | CLASS - 1 | I OBSERVED THE EMERGENCY DISCONNECT FOR THE GENERATOR INSTALLED IN THE MAIN ELECTRICAL ROOM AS PER BC 2702.1.7 , THIS... | $625 | $0 | May 23, 2025 |
| Oct 3, 2024 | 39126529R | RESOLVE | CLASS - 2 | OBSERVED SPRINKLER DRAIN DOWN RISER THROUGHOUT BUILDING NOT PAINTED RED. AS PER 903.6.1 OF THE BUILDING CODE NEW BUIL... | $0 | $0 | Dec 11, 2024 |
| Oct 3, 2024 | 39126530Y | RESOLVE | CLASS - 2 | OBSERVED EXCESSIVE COMBUSTIBLE STORAGE IN THE MECHANICAL ROOM LOCATED AT EXPOSURE 1 OF THE MAIN FLOOR. APPROXIMATELY ... | $0 | $0 | Dec 11, 2024 |
| Sep 24, 2024 | 39125683K | RESOLVE | CLASS - 1 | : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON IN... | $3,125 | $3,125 | Jan 7, 2027 |
| Jul 27, 2023 | 39519842K | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OF A 9 STORY BUILDING, I OBSERVED THAT THE SIDEWALK WAS CRACKED UP AND BROKEN, CREATING A TRIPP... | $2,500 | $2,500 | Feb 16, 2024 |
| Jul 27, 2023 | 39519850K | RESOLVE | CLASS - 1 | INSPECTION OF A 9 STORY BUILDING WITH 2 ELEVATORS IN PLACE, I REQUESTED TO SEE THE TEMPORARY CERTIFICATE FOR USE, NON... | $2,500 | $0 | Feb 16, 2024 |
| Jun 13, 2023 | 39517765R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFOLD:AT INSPECTION IT WAS OBSERVED SCAFFOLD AT EXP.1 & ROOF DECK THAT WORK PLA... | $0 | $0 | Aug 23, 2023 |
| Jun 13, 2023 | 39517772P | RESOLVE | CLASS - 2 | AT INSPECTION, IT WAS OBSERVED: FAILURE TO PROVIDE/MAINTAIN ADEQUATE HOUSEKEEPING WITH CONSTRUCTION MATERIALS AND DEB... | $0 | $0 | Aug 23, 2023 |
| Jun 13, 2023 | 39517771N | RESOLVE | CLASS - 2 | AT INSPECTION, IT WAS OBSERVED: FAILURE TO RENEW EXPIRED SIDEWALK SHED PERMIT #B00713799-I1-SH ISSUED ON 04/07/2022 A... | $0 | $0 | Aug 23, 2023 |
| Mar 28, 2023 | 39514739J | RESOLVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OBSERVED WORKERS PERFORMING WORK ON SITE UPON REQUEST TO SEE YUNYING GAO AND WEI GUO LIU... | $5,000 | $0 | Jun 7, 2023 |
| Mar 28, 2023 | 39514738H | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED SWS INSTALLED AT EXPOSURE #1 WITH BROKEN/ROTTEN/CRACKED/DETERIORATED AND SPLI... | $2,400 | $0 | Jun 7, 2023 |
| Apr 7, 2022 | 35647156L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED:AT TIME OF INSPECTION OF ACTIVE JOBSITE OBSE... | $2,500 | $2,500 | Nov 17, 2022 |
| Sep 21, 2021 | 35589982K | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. AT TIME OF INSPECTION OF AN INACTIVE 9 STY BLDG NOTICED SITE ... | $5,000 | $5,000 | Jun 24, 2022 |
| Sep 15, 2021 | 35583222K | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE.AT TIME OF INSPECTION OF A 9 STORY NEW BUILDING 51 S... | $0 | $0 | Jan 30, 2023 |
| Sep 15, 2021 | 35583221Z | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.AT TIMEOF INSPECTION OF A 9 STORY NEW BUILDING OBSERVE... | $12,500 | $12,500 | Jun 24, 2022 |
| Jul 1, 2021 | 39043847Z | RESOLVE | CLASS - 1 | CEASE USE; TEMPORARY CONSTRUCTION ELEVATOR LOCATED INSIDE A BUILDING CANNOT BE POWERED BY A GENERATOR. REMEDY; PROVID... | $3,125 | $0 | Apr 29, 2022 |
| Jun 15, 2021 | 35551932Z | RESOLVE | CLASS - 1 | 3303.8-FAILURE TO PROVIDE STAND PIPE AS REQUIRED NOTE AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING AT 8TH F... | $0 | $0 | Aug 1, 2022 |
| Jun 15, 2021 | 35551930P | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE SAFETY EQUIPMENT MEASURE NO GUARDRAILS NOTE AT THE TIME OF MY INSPECTION OBSERVED EXP-3 GRADE LE... | $12,500 | $12,500 | Jun 13, 2022 |
| Jun 15, 2021 | 35551929H | RESOLVE | CLASS - 1 | BC3314.8-FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFODL AS REQUIRED NO GUARDRAILS NOTE AT THE TIME OF MY INSPECTION OBSE... | $6,250 | $6,250 | Jun 13, 2022 |
| Jan 8, 2021 | 35543105P | RESOLVE | CLASS - 1 | SEC. 3308.6 FAILURE TO PROVIDE HORIZONTAL/NETTING OR ALTERATE SUPPORTED PIPE SCAFFOLD W/DEBRIS NETTING. NOTE: AT TIME... | $2,500 | $2,500 | May 19, 2021 |
| Jan 8, 2021 | 35543106R | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE SAFETY EQUIPMENT MEASURES-INADEQUATE GUARDRAILS. NOTE: AT TIME OF MY INSPECTION OBSERVED ACTIVE ... | $2,500 | $2,500 | May 19, 2021 |
| Jan 8, 2021 | 35543107Z | RESOLVE | CLASS - 1 | SEC. 33363.12 FAILURE TO PROVIDE HOIST/ELEVATOR. NOTE: AT TIME OF MY INSPECTION OF A 9 STY NEW BLDG AT ROOF LEVEL UND... | $2,500 | $2,500 | May 19, 2021 |
| Nov 18, 2020 | 35538493J | RESOLVE | CLASS - 1 | BC1905.15 FAILURE TO IMPLEMENT COLD WEATHER REQUIREMENTS FOR CONCRETE PLACED DURING FREEZING OR NEAR FREEZING WEATHER... | $2,500 | $2,500 | Mar 31, 2021 |
| Nov 18, 2020 | 35538456K | RESOLVE | CLASS - 1 | BC3301.2-FAILURE TO MAINTAIN EMBEDDED SAFTEY STRAP LOG BOOK ADEQUATELY AS NOTED AT TIME OF MY INSPECTION OF AN ACTIVE... | $2,500 | $2,500 | Mar 31, 2021 |
| Nov 18, 2020 | 35538497R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ADEQUATE CARING BOX.AS NOTED:AT TIME OF INSPECTION FOR AN ACTIVE CONSTRUCTION SITE AT 8TH FL LEVEL... | $2,500 | $2,500 | Mar 31, 2021 |
| Nov 18, 2020 | 35538454R | RESOLVE | CLASS - 1 | BC3305.3.6.1.2-FAILURE TO SECURE RESHORE AS NOTED AT THE TIME OF MY INSPECTION AT AN ACTIVE CONSTRUCTION SITE OBSERVE... | $2,500 | $2,500 | Mar 31, 2021 |
| Oct 23, 2020 | 35537823Z | RESOLVE | CLASS - 1 | 1906.6.6.1.2 FAILURE TO SECURE RESHORES IN PROXIMITY TO THE LEADING EDGE. AS NOTED AT TIME OF MY INSPECTION ON AN ACT... | $2,500 | $2,500 | Apr 9, 2021 |
| Aug 13, 2020 | 35492503N | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION,OBSERVED ON GOING CONSTRUCTION ACTIVITIES CONTRARY TO MAYORS EMERGENCY EXECUTIVE ORDER 120 & SU... | $5,000 | $5,000 | Nov 29, 2021 |
| Jan 30, 2020 | 35467422R | RESOLVE | CLASS - 1 | SEC. 3303.4.1.1 FAILURE TO MAINTAIN SIDEWALK IN A SAFE MANOR. AT TIME OF INSPECTION OF A 9 STY NB CURRENTLY AT GRADE ... | $625 | $625 | Jan 11, 2021 |