| Jun 10, 2015 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTER AT HANDRAIL AT PUBLIC HALL, 2nd STORY | — | Jun 18, 2015 |
| Jun 10, 2015 | A | VIOLATION CLOSED | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH O... | — | Sep 13, 2015 |
| Aug 21, 2014 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BAT... | 3L | Nov 24, 2014 |
| Jun 26, 2014 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 3L | Jul 24, 2014 |
| Jun 23, 2014 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASHBASIN WASTELINE, IN THE BATHROOM LOCATED AT AP... | 3L | Jul 28, 2014 |
| Jun 23, 2014 | C | VIOLATION CLOSED | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd S... | 3L | Jun 21, 2014 |
| Jun 23, 2014 | B | VIOLATION CLOSED | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STO... | 3L | Jul 28, 2014 |
| Jun 23, 2014 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASHBASIN WASTELINE, IN THE BATHROOM LOCAT... | 3L | Jul 28, 2014 |
| Jun 23, 2014 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | 3L | Jul 28, 2014 |
| Jun 23, 2014 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING, LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FR... | 3L | Jul 28, 2014 |
| Jun 23, 2014 | C | VIOLATION CLOSED | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR TO CELLAR LOCKED , AT PUBLIC HALL, 1st... | — | Jul 1, 2014 |
| Apr 3, 2014 | C | VIOLATION CLOSED | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd S... | 3L | Apr 2, 2014 |
| Mar 13, 2014 | C | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT CAPABLE OF BEING PADLOCKED AT ROOF BULKHEAD DO... | — | Mar 21, 2014 |
| Mar 13, 2014 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WIRE GLASS AT SKYLIGHT AT ROOF | — | Mar 21, 2014 |
| Mar 11, 2014 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | 3L | Apr 15, 2014 |
| Mar 11, 2014 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd ... | 3L | Apr 15, 2014 |
| Jan 21, 2014 | B | VIOLATION CLOSED | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AN... | — | Feb 25, 2014 |
| Jan 17, 2014 | B | VIOLATION CLOSED | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT ... | — | Feb 21, 2014 |
| Nov 13, 2012 | C | VIOLATION CLOSED | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd S... | 3R | Nov 9, 2012 |
| Nov 13, 2012 | C | VIOLATION CLOSED | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 2R | Nov 9, 2012 |
| Nov 13, 2012 | C | VIOLATION DISMISSED | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd S... | 2R | Nov 9, 2012 |
| Nov 13, 2012 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE OF THE LOWER SASH AT EAST 2 WINDOW I... | 2R | Nov 19, 2012 |
| Nov 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, APA... | 2R | Dec 18, 2012 |
| Nov 13, 2012 | C | VIOLATION CLOSED | SECTION 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPR... | 3R | Nov 9, 2012 |
| Nov 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, ... | 2R | Dec 18, 2012 |
| Nov 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | 2R | Dec 18, 2012 |
| Nov 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE E... | 2R | Dec 18, 2012 |
| Nov 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOMMUNICATION SYSTEM IN THE ENTRANC... | 2R | Dec 18, 2012 |
| Nov 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER AND LOWER SASHES OF WINDOW AT EAST IN THE BATH... | 2R | Dec 18, 2012 |
| Oct 17, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR AT VESTIBULE | — | Nov 21, 2011 |
| Oct 17, 2011 | B | VIOLATION CLOSED | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT ... | — | Nov 21, 2011 |
| Sep 26, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WAL... | 2L | Oct 31, 2011 |
| Sep 26, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE METAL CEILING IN THE KITCH... | 2L | Oct 31, 2011 |
| Sep 26, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE KITCHEN LOC... | 2L | Oct 31, 2011 |
| Sep 26, 2011 | B | VIOLATION CLOSED | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STO... | 2L | Oct 31, 2011 |
| Sep 26, 2011 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS APT. DOOR IN THE ENTRANCE LOCATED AT APT 2L, 2... | 2L | Oct 31, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER LEAK OVER CEILING IN THE BATHROOM LOCAT... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN TH... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, ... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CEILING IN THE KITCHEN L... | 2L | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK AT CEILING IN THE BATH... | 2L | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd ... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WAL... | 2L | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCE LOWER SASH IN THE KITCHEN LOCATED AT ... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASHES STACK IN THE BATHROOM LOCATED AT APT 2... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZER SYSTEM IN THE ENTRANCE LOCATED AT APT 2R... | 2R | Oct 17, 2011 |
| Sep 12, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS IN THE ... | 2R | Oct 17, 2011 |
| Mar 15, 2010 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL NOSING AT TREADS 1,2,3,4, UP AT PUBLIC HALL S... | — | Apr 19, 2010 |
| Dec 7, 2009 | A | VIOLATION CLOSED | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME... | — | Mar 12, 2010 |