Pitkin Avenue, Brooklyn
Brooklyn • Block 03741 • Lot 0024 • Zip: 11207
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Downtown Brooklyn 45 min 13 walking, 32 riding
- Fulton Street 52 min 13 walking, 39 riding
- Union Square 58 min 13 walking, 45 riding
- Grand Central 62 min 13 walking, 49 riding
- Penn Station 62 min 13 walking, 49 riding
- Times Square 63 min 13 walking, 50 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Places nearby
Happy
Happy Cafe is a cozy spot in Brooklyn offering delicious coffee, pastries, and sandwiches. Enjoy the warm and invitin...
Sweets & Things
No description yet
JMG Restaurant
West African restaurant
LA REPUBLIKA BAR LOUNGE AND REST.
Bar, grill and lounge
Room 1 Hundred
Polished venue with a mahogany bar & a patio serving mofongo, seafood & other Dominican fare.
Festac Grill
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2017
-
HPD violation Dec 6, 2017
Class B
§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE...
-
HPD violation Dec 6, 2017
Class B
§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING AND ALL W...
-
HPD violation Dec 6, 2017
Class B
§ 27-2005,2007 ADMIN. CODE: FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR GATES FROM WINDOW TO FIRE ESCAPE ... IN...
-
HPD violation Dec 6, 2017
Class B
§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CEILING LIGHT FIXTURE IN THE 1st ROOM FROM NORTH LOCATED AT APT 2...
-
HPD violation Dec 6, 2017
Class B
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE RETURN BUZZER INTERCOM SYSTEM FROM ENTRANCE DOOR TO IN...
-
HPD violation Dec 6, 2017
Class B
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING AND WEST WALL (APP...
-
DOB violation Feb 8, 2017
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Feb 8, 2017
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2016
-
CLASS - 1
SEC: FGC CH4. PIPING &/OR EQUIPMENT INSTALLED INPROPERLY: OBSERVED HAS BEEN MADE @ 4:30PM ABOVE THE GAS METER ON THE ...
-
CLASS - 1
WORK W/OUT PERMIT WORK NOTED OBSERVED @ 4:30PM IN CELLAR WHICH ACCESS WAS GIVEN BY STORE AS PER DISAPPROVED LAA# 3208...
2014
2008
-
Hazardous
FAILURE TO MAINTAIN BLDG DEFECT NOTED: AT WEST PERIMETER ROOF LEVEL-CORNICE METAL MOLDING OF BLDG IS LOOSE AND MISSIN...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records