May 14, 2019 35398214X RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35311374K ISSUED ON 03/05/18 AND TO FIL... $1,250 $1,250 Feb 6, 2020
Nov 24, 2018 35392279J RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35311374K ISSUED ON 03-05-18 & TO FILE A C OF C PURSUAN... $1,250 $1,250 Jun 17, 2019
Oct 13, 2018 35390076K RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35311374K ISSUED ON 03-05-18 & TO FILE A C OF C PURSUAN... $1,250 $1,250 Apr 8, 2019
Jul 21, 2018 35386991M RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35311374K ISSUED ON 3/5/18 AND TO FIL... $1,250 $1,250 Dec 17, 2018
Jun 9, 2018 35339880H RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMM'S ORDER CONTAINED IN SUMM/VIO#35311374K ISSUED ON 04/14/18 AND TO FILE A COFC PURSUANT TO 28... $1,250 $1,250 Jan 16, 2019
Apr 20, 2018 35329403X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS.NOTED:REAR BRICKWALL HAS MULTIPLE CRACKS BETWEEN WINDOW,VERTICAL CRACKS THROUGHOUT... $5,000 $5,000 Jun 18, 2018
Apr 20, 2018 35336664J RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER ORDER CONTAINED IN SUMMONS/VIOLATION#35311374K ISSUED ON 03/05/18 AND TO FILE... $3,125 $3,125 Jun 18, 2018
Mar 5, 2018 35321709M RESOLVE CLASS - 3 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN BASEMENT. THE INSTALLATION OF A GFCI RECEPTACLE PRIOR TO OBTAINING AN E... $400 $400 Jul 5, 2018
Mar 5, 2018 35311373Z RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT EXP 3 REAR OF BUILDING CRACK GOING FROM 1ST FLOOR TO... $500 $500 Jun 18, 2018
Mar 5, 2018 35312065L ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. OBSERVED ON 03/05/18 AT ABOVE ADDRESS UNSUPPORTED STEAM PIPING... $500 $500 Jul 3, 2018
Mar 5, 2018 35311372R RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. AT CELLAR LEVEL HOLE IN... $1,250 $1,250 Jun 19, 2018
Mar 5, 2018 35311374K RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: CELLAR LEVEL BY BOILER ROOM MISSING LALLY COLUMN. FOOTI... $500 $500 Jun 19, 2018
Nov 8, 2017 35279503K RESOLVE CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35228900Y ISSUED 02/15/17 AND TO FILE... $6,000 $0 Apr 16, 2018
Oct 1, 2017 35278848L RESOLVE CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIO # 35228900Y ISSUED ON 02/15/17 & TO FILE A C... $2,400 $0 Nov 20, 2017
Jul 24, 2017 35276072Y RESOLVE CLASS - 1 FAILURE TO COMPLY W/COMMISSIONER'S ORDER IN SUMMONS/VIOLATION 335228900Y ISSUED ON 2/15/17 AND TO FILE A CERTIFICATE ... $2,400 $0 Mar 12, 2018
Jul 21, 2017 35272332N RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:NO FIRE STOPPINGPER BC712.3'27-345.NOTED:OBSERVED AT CELLAR AT ... $500 $0 Nov 29, 2017
Jul 21, 2017 35286740J ACTIVE CLASS - 2 UNAPPROVED,UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS,DEVICE,APPLIANCE OR WIRING IN USE. OBSERVED EMT... $800 $0 Nov 29, 2017
Jul 21, 2017 35286753Z RESOLVE CLASS - 2 FAILURE TO FILE A COMPLETE BOILER INSP REPORT ANNUALLY. OBSERVED FROM DOB RECORDS THAT THE LAST COMPLETE BOILER INSP ... $0 $0 Nov 29, 2017
Jul 21, 2017 35286741L ACTIVE CLASS - 2 FAILURE TO PROVIDE GROUND FAULT CIRCUIT INTERRUPTOR (GFCI) AS REQUIRED. OBSERVED DUPLEX RECEPTACLE OUTLET NOT OF THE ... $2,400 $0 Nov 29, 2017
Jul 21, 2017 35286752R ACTIVE CLASS - 1 SEC: FGC 408.2. FUTURE CONNECTION EXIST ON GAS PIPING. OBSERVED IN SEVERAL LOCATIONS IN CELLAR FUTURE CONNECTIONS EXI... $2,000 $0 Nov 29, 2017
Jul 21, 2017 35286751P ACTIVE CLASS - 1 SEC: FGC 407.2. SUPPORTS FOR GAS PIPING NOT PROPER ON MISSING. OBSERVED @ EXP#4 OF BLDG VENT PIPING FOR GAS REGULATOR... $800 $0 Nov 13, 2017
Jun 8, 2017 35234183L RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35228900Y ISSUED ON 2-15-17 & TO FILE A C OF C PURSUANT... $2,400 $0 Jan 22, 2018
Apr 10, 2017 35232881J RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35228900Y ISSUED ON 2-15-17 & TO FILE A C OF C PURSUANT... $6,000 $0 Jun 5, 2017
Feb 15, 2017 35228900Y RESOLVE CLASS - 1 WORK NO PERMIT-OBSERVED IN 2/15/17 AT 8:30PM IN CELLAR-NEW GAS PIPING TO METER AND VALVES SUPPORT.NO DOB PERMIT FOR T... $0 $0 Feb 28, 2023
Feb 15, 2017 35228902H RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:FAILURE TO COMPLY WITH LAW OF DRAINAGE SYSTEM PER PC702.1-27-91... $0 $0 Feb 28, 2023
Feb 15, 2017 35228903J RESOLVE CLASS - 2 FAILURE TO FILE COMMISIONER'S ORDER TO FILE A CERTIFCATE OF CORRECTIONWITH THE DEPT OF BUILDINGS ECB 35213998J.REMEDY... $0 $0 Feb 28, 2023
Feb 15, 2017 35228901X RESOLVE CLASS - 1 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.-INSTALLED 3/4 GAS PIPING AT GAS METER WITH FITTING(S)& VALBE-N... $0 $0 Feb 28, 2023
Dec 7, 2016 35189182J RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35213998J ISSUED ON 10/03/16 & TO FILE A C OF C PURSUANT TO 28... $800 $0 Mar 15, 2017
Oct 3, 2016 35213999L RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FAILURE TO COMPLY WITH LAW FOR WATER SUPPLY SYSTEM PER PC 6023;... $250 $0 Nov 30, 2016
Oct 3, 2016 35207360J RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NO FIRE STOPPING BC 712.3;27-245.NOTED:@CELLAR MULTIPLE LOCATION @C... $250 $0 Nov 21, 2016
Oct 3, 2016 35213996X ACTIVE CLASS - 1 FGC408.2 MISC VIOLATIONS. DRIPS-FUTURE CONNECTS EXIST DOWN STREAM OF APPLIANCE.OBSERVED ON 10/03/16 AT 2:25PM FUTURE ... $1,600 $0 Nov 30, 2016
Oct 3, 2016 35213997H RESOLVE CLASS - 1 FGC 401.5 MISC.VIOLATIONS GAS PIPING NOT LABELED OBSERVATION ON 10/03/16 AT 2:25 PM GASW PIPES IN BASEMENT WERE NOT L... $400 $0 Nov 30, 2016
Oct 3, 2016 35207359M RESOLVE CLASS - 2 WORK W/O A PERMIT.WORK NOTED:INSTALLING(CREATING)A BATHROOM (2PCS, TOILET &SINK),ERECTING FULL HEIGHT PARTITIONS FOR ... $800 $0 Jan 30, 2017
Oct 3, 2016 35213998J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED ON 10/03/16 2:25PM ON ADHS INSPECTION A GAS LEAK IN TH... $1,000 $0 Nov 30, 2016
Mar 21, 2016 35177262L RESOLVE CLASS - 2 FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER. DEFECTS NOTED: AT 1ST FLAPT #A1,A3,A4 & A5 WATER DAMAGE TO CEILING AT B... $1,250 $0 May 9, 2016